==2024.06.15: PoE Alternative change==

Starting from 2024 Q2, TSW100 switch will be produced with PoE alternative A instead of alternative B.

{| class="wikitable"
|-
| style="width: 1219px; text-align: left; background: #eeece1;" |PCN Number: PCN_TSW100_2024_02_29_EN <br>
|-
|}

{| class="wikitable"
|+
! colspan="2" style="text-align: left; background: #eeece1;" |Change description
|-
| style="text-align: left; background: white;" |Change type
| style="text-align: left; background: white;" |Hardware change
|-
| style="width: 221px; text-align: left; background: white;" | Detailed description
| style="width: 908px; text-align: left; background: white;" | In order to ensure better compatibility with other devices, starting from 2024 Q2, TSW100 switch will be produced with PoE alternative A. For more information about PoE alternative A and alternative B, please visit: wiki.teltonika-networks.com/view/TSW100_First_Start <br>
|-
| style="text-align: left; background: white;" | Change reasons
| style="text-align: left; background: white;" | Increasing compatibility.
|-
|}

{| class="wikitable"
|+
! style="text-align: left; background: #eeece1;" colspan="3" | Affected products information
|-
| style="width: 221px; text-align: left; background: white;" | Model
| style="width: 448px; text-align: left; background: white;" | Affected order codes
| style="width: 448px; text-align: left; background: white;" | Order code changes
|-
| style="text-align: left; background: white;" | TSW100
| style="text-align: left; background: white;" | TSW100 *****
| style="text-align: left; background: white;" | No changes
|-
| style="text-align: left; background: white;" | Upcoming change date
| style="text-align: left; background: white;" colspan="2" | 2024 Q2
|-
|}

{| class="wikitable"
|+
! style="text-align: left; background: #eeece1;" colspan="3" | Change impact
|-
| style="width: 221px; text-align: left; background: white;" | Risk assessment
| style="width: 908px; text-align: left; background: white;" colspan="2"|
Devices exclusively dependent on PoE alternative B will be incompatible with the TSW100 switch. However, it's important to note that such instances are uncommon.
|-
| style="text-align: left; background: white;" | Suggested implementation plan
| style="text-align: left; background: white;" colspan="2"|
Information included in this PCN will help adapt to the upcoming changes. For more detailed information, please contact your sales representative.
|-
|}

{| class="wikitable"
|+
! style="width: 1141px; text-align: left; background: #eeece1;" colspan="3" | Acknowledgement of PCN receipt
|-
| style="text-align: left; background: white;" colspan="3"| If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above.
|-
|}

To download the pdf version of this notification, [[Media:PCN_PoE_Alternative_change.pdf|click here]].