Changes

no edit summary
Line 117: Line 117:  
     </tr>
 
     </tr>
 
</table>
 
</table>
 +
 +
    
[[File:Networking_rutos_manual_mbus_client_data_collecting_groups_value_edit.png|border|class=tlt-border]]
 
[[File:Networking_rutos_manual_mbus_client_data_collecting_groups_value_edit.png|border|class=tlt-border]]
Line 229: Line 231:  
     </tr>
 
     </tr>
 
</table>
 
</table>
 +
 +
    
[[File:Networking_rutos_manual_mbus_gateway_configuration_settings_security.png|border|class=tlt-border]]
 
[[File:Networking_rutos_manual_mbus_gateway_configuration_settings_security.png|border|class=tlt-border]]
Line 274: Line 278:  
     </tr>
 
     </tr>
 
</table>
 
</table>
 +
 +
    
[[File:Networking_rutos_manual_mbus_gateway_configuration_settings_advanced.png|border|class=tlt-border]]
 
[[File:Networking_rutos_manual_mbus_gateway_configuration_settings_advanced.png|border|class=tlt-border]]
Line 344: Line 350:  
     </tr>
 
     </tr>
 
</table>
 
</table>
  −
  −
  −
  −
  −
  −
  −
  −
  −
  −
  −
The <b>M-Bus Settings</b> section is used to configure the general service functionality. The figure below is an example of the M-Bus Settings and the table below provides information on the fields contained in that section:
  −
  −
[[File:Networking_rutos_manual_mbus_mbus_settings_v1.png|border|class=tlt-border]]
  −
  −
<table class="nd-mantable">
  −
    <tr>
  −
        <th>Field</th>
  −
        <th>Value</th>
  −
        <th>Description</th>
  −
    </tr>
  −
    <tr>
  −
        <td>Enable</td>
  −
        <td>off | on; default: <b>off</b></td>
  −
        <td>Enables the service.</td>
  −
    </tr>
  −
    <tr>
  −
        <td>Baud rate</td>
  −
        <td>300 | 600 | 1200 | 2400 | 4800 | 9600 ; default: <b>2400</b></td>
  −
        <td>Specifies the M-Bus server network baud rate.</td>
  −
    </tr>
  −
    <tr>
  −
        <td>Database location</td>
  −
        <td>RAM memory | Flash memory; default: <b>RAM memory</b></td>
  −
        <td>Specifies where the database will be stored..</td>
  −
    </tr>
  −
</table>
  −
  −
==Records==
  −
  −
By default there are no <b>Records</b> instances created. To start configuring, add a new record using the <b>Add New Instance</b> section below.
  −
  −
[[File:Networking_rutos_manual_mbus_records_add_new_instance_v1.png|border|class=tlt-border]]
  −
  −
----
  −
  −
===M-Bus Record===
  −
----
  −
The <b>M-Bus Record</b> section is used to configure the general record instance. The figure below is an example of the M-Bus Record and the table below provides information on the fields contained in that section:
  −
  −
[[File:Networking_rutos_manual_mbus_record_mbus_record_demo_v4.png|border|class=tlt-border]]
  −
  −
<table class="nd-mantable">
  −
    <tr>
  −
        <th>Field</th>
  −
        <th>Value</th>
  −
        <th>Description</th>
  −
    </tr>
  −
    <tr>
  −
        <td>Enable</td>
  −
        <td>off | on; default: <b>off</b></td>
  −
        <td>Enables the service.</td>
  −
    </tr>
  −
    <tr>
  −
        <td>Name</td>
  −
        <td>string; default: <b>none</b></td>
  −
        <td>Name used for distinguishing purposes.</td>
  −
    </tr>
  −
    <tr>
  −
        <td>Period</td>
  −
        <td>integer [1..86400]; default: <b>60</b></td>
  −
        <td>Specifies the period how often record data will be collected.</td>
  −
    </tr>
  −
    <tr>
  −
        <td>String before data</td>
  −
        <td>string; default: <b>none</b></td>
  −
        <td>String that will be appended before request data.</td>
  −
    </tr>
  −
    <tr>
  −
        <td>String between data</td>
  −
        <td>string; default: <b>none</b></td>
  −
        <td>String that will be appended between request data.</td>
  −
    </tr>
  −
    <tr>
  −
        <td>String after data</td>
  −
        <td>string; default: <b>none</b></td>
  −
        <td>String that will be appended after request data.</td>
  −
    </tr>
  −
    <tr>
  −
        <td>Failure mode</td>
  −
        <td>Never | <span style="color: red;">Any requests failed</span> | <span style="color: red;">All requests failed</span>; default: <b>Never</b></td>
  −
        <td>Specifies when whole record is considered as failure.</td>
  −
    </tr>
  −
    <tr>
  −
        <td><span style="color: red;">Store a failure message</span></td>
  −
        <td>off | on; default: <b>off</b></td>
  −
        <td>Select whether to store a failure message in the database or do nothing on failure.</td>
  −
    </tr>
  −
</table>
  −
  −
===Request Configuration===
  −
----
  −
In this section, you can configure requests from servers. By default there are no instances created. To add a new instance and start configuring press the <b>Add</b> button.
  −
  −
[[File:Networking_rutos_manual_mbus_record_request_configuration_v2.png|border|class=tlt-border]]
  −
  −
====Request Configuration Edit====
  −
----
  −
[[File:Networking rutos manual mbus record request configuration edit v4.png|border|class=tlt-border]]
  −
  −
<table class="nd-mantable">
  −
    <tr>
  −
        <th>Field</th>
  −
        <th>Value</th>
  −
        <th>Description</th>
  −
    </tr>
  −
    <tr>
  −
        <td>Enable</td>
  −
        <td>off | on; default: <b>off</b></td>
  −
        <td>Enables request processing.</td>
  −
    </tr>
  −
    <tr>
  −
        <td>Server address</td>
  −
        <td>int | hexstring; default: <b>none</b></td>
  −
        <td>Address of the server to be inquired.</td>
  −
    </tr>
  −
    <tr>
  −
        <td>Data type</td>
  −
        <td>XML | HEX | BIN | JSON; default: <b>XML</b></td>
  −
        <td>Data type to process the received data.</td>
  −
    </tr>
  −
    <tr>
  −
        <td>Error value</td>
  −
        <td>string; default: <b>none</b></td>
  −
        <td>Changes request data to this value if request fails.</td>
  −
    </tr>
  −
    <tr>
  −
        <td>FCB toggle</td>
  −
        <td>off | on; default: <b>on</b></td>
  −
        <td>FCB (Frame Count-Bit): One-bit counter for reliable server-client communication; some devices have special uses for it.</td>
  −
    </tr>
  −
    <tr>
  −
        <td>Reset after read</td>
  −
        <td>off | on; default: <b>off</b></td>
  −
        <td>Resets the device after every read.</td>
  −
    </tr>
  −
    <tr>
  −
        <td>Test configuration</td>
  −
        <td>button; default: <b>-</b></td>
  −
        <td>Tests the current configuration.</td>
  −
    </tr>
  −
</table>
  −
  −
====Test Configuration====
  −
----
  −
Before saving, you can check if your configuration works accordingly by pressing the <b>Test Configuration</b> button. You should see the data in a field below:
  −
  −
[[File:Networking_rutos_manual_mbus_record_request_configuration_edit_test_configuration_v1.png|border|class=tlt-border]]
      
[[Category:{{{name}}} Services section]]
 
[[Category:{{{name}}} Services section]]