Line 2: |
Line 2: |
| <tr style="font-weight:bold"> | | <tr style="font-weight:bold"> |
| <th width=800>Test type</th> | | <th width=800>Test type</th> |
− | <th width=150>Current (mA)</span></th> | + | <th width=150><center>Current (mA)</span></th> |
− | <th width=150>Power consumption (W)</th> | + | <th width=170><center>Power consumption (W)</th> |
| </tr> | | </tr> |
| <tr> | | <tr> |
| <td>Idle (12 V)</td> | | <td>Idle (12 V)</td> |
− | <td><b>77</b></td> | + | <td><center><b>77</b></td> |
− | <td><b>0.93</b></td> | + | <td><center><b>0.93</b></td> |
| </tr> | | </tr> |
| <tr> | | <tr> |
| <td>Idle (24 V)</td> | | <td>Idle (24 V)</td> |
− | <td><b>52</b></td> | + | <td><center><b>52</b></td> |
− | <td><b>1.24</b></td> | + | <td><center><b>1.24</b></td> |
| </tr> | | </tr> |
| <tr> | | <tr> |
| <td>Idle (54 V)</td> | | <td>Idle (54 V)</td> |
− | <td><b>34</b></td> | + | <td><center><b>34</b></td> |
− | <td><b>1.81</b></td> | + | <td><center><b>1.81</b></td> |
| </tr> | | </tr> |
| </table> | | </table> |
Line 26: |
Line 26: |
| <tr style="font-weight:bold"> | | <tr style="font-weight:bold"> |
| <th width=800>Test type</th> | | <th width=800>Test type</th> |
− | <th width=150>Current (mA)</span></th> | + | <th width=150><center>Current (mA)</span></th> |
− | <th width=150>Power consumption (W)</th> | + | <th width=170><center>Power consumption (W)</th> |
| </tr> | | </tr> |
| <tr> | | <tr> |
− | <td>8 LAN and 2 SFP devices connected + heavy data traffic (12 V)</td> | + | <td>8 LAN and 2 SFP devices connected + heavy data traffic<sup><small>1</small></sup> (12 V)</td> |
− | <td><b>381</b></td> | + | <td><center><b>381</b></td> |
− | <td><b>4.57</b></td> | + | <td><center><b>4.57</b></td> |
| </tr> | | </tr> |
| <tr> | | <tr> |
− | <td>8 LAN and 2 SFP devices connected + heavy data traffic (24 V)</td> | + | <td>8 LAN and 2 SFP devices connected + heavy data traffic<sup><small>1</small></sup> (24 V)</td> |
− | <td><b>200</b></td> | + | <td><center><b>200</b></td> |
− | <td><b>4.80</b></td> | + | <td><center><b>4.80</b></td> |
| </tr> | | </tr> |
| <tr> | | <tr> |
− | <td>8 LAN and 2 SFP devices connected + heavy data traffic (54 V)</td> | + | <td>8 LAN and 2 SFP devices connected + heavy data traffic<sup><small>1</small></sup> (54 V)</td> |
− | <td><b>103</b></td> | + | <td><center><b>103</b></td> |
− | <td><b>5.54</b></td> | + | <td><center><b>5.54</b></td> |
| </tr> | | </tr> |
| </table> | | </table> |
Line 50: |
Line 50: |
| <tr style="font-weight:bold"> | | <tr style="font-weight:bold"> |
| <th width=800>Test type</th> | | <th width=800>Test type</th> |
− | <th width=150>Current (mA)</span></th> | + | <th width=150><center>Current (mA)</span></th> |
− | <th width=150>Power consumption (W)</th> | + | <th width=170><center>Power consumption (W)</th> |
| </tr> | | </tr> |
| <tr> | | <tr> |
− | <td>2 SFP devices connected + 4 PoE devices (RUTX08, RUTX09, RUTX10, RUTX11) connected + 4 PoE dummy loads connected (30 W each) + heavy data traffic (54 V)</td> | + | <td>2 SFP devices connected + 4 PoE devices <sup><small>2</small></sup> (RUTX08, RUTX09, RUTX10, RUTX11) connected + <br> 4 PoE dummy loads connected (30 W each) + heavy data traffic<sup><small>1</small></sup> (54 V)</td> |
− | <td><b>2405</b></td> | + | <td><center><b>2405</b></td> |
− | <td><b>137.10</b></td> | + | <td><center><b>137.10</b></td> |
| </tr> | | </tr> |
| </table> | | </table> |
| + | |
| + | |
| + | <small><sup><small>1</small></sup> - Data streams between devices were created using iPerf.</small> <br> |
| + | <small><sup><small>2</small></sup> - RUTX08, RUTX10, RUTX11 and RUTX12 support [[Passive Power over Ethernet (PoE)|Passive PoE]] and for this test were powered using PoE converters.</small> <br> |
| + | <small>Power consumption may differ due to testing environment and conditions.</small> |