Line 18: |
Line 18: |
| <b>Note:</b> OPC UA is additional software that can be installed from the <b>System → [[{{{name}}} Package Manager|Package Manager]]</b> page.</u> | | <b>Note:</b> OPC UA is additional software that can be installed from the <b>System → [[{{{name}}} Package Manager|Package Manager]]</b> page.</u> |
| | | |
− | ==OPC UA Configuration== | + | ==OPC UA Servers== |
− | The <b>OPC UA Configuration</b> section is used to enable the service. | + | The OPC Server is the basis of OPC communication. It is a software that implements the OPC standard and thus provides the standardized OPC interfaces to the outside world. |
| | | |
− | [[File:Networking_rutos_manual_opcua_opcua_configuration_v1.png|border|class=tlt-border]]
| + | Notice the Global section config. It is used to outright turn the service off or on if any active configurations are present. |
| | | |
− | <table class="nd-mantable">
| + | [[File:Networking rutos manual opcua opcua client devices global button v1.png|border|class=tlt-border]] |
− | <tr>
| + | |
− | <th>Field</th>
| + | Clicking the Cog icon opens a modal window. The global configuration slider can be set and it's state saved. |
− | <th>Value</th>
| + | |
− | <th>Description</th>
| + | [[File:Networking rutos manual modbus modbus tcp client modbus tcp server devices global config modal v1.png|border|class=tlt-border]] |
− | </tr>
| + | |
− | <tr>
| + | To add a new server, enter an instance name and click the 'Add' button. |
− | <td>Enable</td>
| |
− | <td>off | on; default: <b>off</b></td>
| |
− | <td>Enables OPC UA service.</td>
| |
− | </tr>
| |
− | </table>
| |
| | | |
− | ==OPC UA Servers==
| + | <b>Note:</b> A maximum of <b>10</b> servers is allowed. |
− | The OPC Server is the basis of OPC communication. It is a software that implements the OPC standard and thus provides the standardized OPC interfaces to the outside world. To add a new server, enter an instance name and click the 'Add' button.
| |
| | | |
| [[File:Networking_rutos_manual_opcua_opcua_servers_add_button_v1.png|border|class=tlt-border]] | | [[File:Networking_rutos_manual_opcua_opcua_servers_add_button_v1.png|border|class=tlt-border]] |
Line 47: |
Line 41: |
| The <b>OPC UA Server Configuration</b> section is used to configure the parameters of an OPC UA Server. | | The <b>OPC UA Server Configuration</b> section is used to configure the parameters of an OPC UA Server. |
| | | |
− | [[File:Networking_rutos_manual_opcua_opcua_servers_server_configuration_v1.png|border|class=tlt-border]] | + | [[File:Networking_rutos_manual_opcua_opcua_servers_server_configuration_v2.png|border|class=tlt-border]] |
| | | |
| <table class="nd-mantable"> | | <table class="nd-mantable"> |
Line 84: |
Line 78: |
| | | |
| By default, there are no nodes configured. To add a new server node, enter an instance name and click the 'Add' button. | | By default, there are no nodes configured. To add a new server node, enter an instance name and click the 'Add' button. |
| + | |
| + | <b>Note:</b> A maximum of <b>50</b> nodes per server are allowed. |
| | | |
| [[File:Networking_rutos_manual_opcua_opcua_servers_server_node_add_button_v1.png|border|class=tlt-border]] | | [[File:Networking_rutos_manual_opcua_opcua_servers_server_node_add_button_v1.png|border|class=tlt-border]] |
Line 129: |
Line 125: |
| | | |
| By default, there are no value groups configured. To add a new group, enter an instance name and click the 'Add' button. | | By default, there are no value groups configured. To add a new group, enter an instance name and click the 'Add' button. |
| + | |
| + | <b>Note:</b> A maximum of <b>20</b> value groups are allowed. |
| | | |
| [[File:Networking_rutos_manual_opcua_opcua_value_groups_add_button_v1.png|border|class=tlt-border]] | | [[File:Networking_rutos_manual_opcua_opcua_value_groups_add_button_v1.png|border|class=tlt-border]] |
Line 205: |
Line 203: |
| | | |
| By default, there are no group values configured. To add a new value, enter an instance name and click the 'Add' button. | | By default, there are no group values configured. To add a new value, enter an instance name and click the 'Add' button. |
| + | |
| + | <b>Note:</b> A maximum of <b>50</b> values per value group is allowed. |
| | | |
| [[File:Networking_rutos_manual_opcua_opcua_value_groups_group_value_add_button_v1.png|border|class=tlt-border]] | | [[File:Networking_rutos_manual_opcua_opcua_value_groups_group_value_add_button_v1.png|border|class=tlt-border]] |