Line 23: |
Line 23: |
| | | |
| [[File:Networking_rutos_manual_mbus_client_general_settings.png|border|class=tlt-border]] | | [[File:Networking_rutos_manual_mbus_client_general_settings.png|border|class=tlt-border]] |
− |
| |
− | [[File:Networking_rutos_manual_mbus_client_device_configuration.png|border|class=tlt-border]]
| |
| | | |
| <table class="nd-mantable"> | | <table class="nd-mantable"> |
Line 44: |
Line 42: |
| </table> | | </table> |
| | | |
− | The Devices section is used to configure the general device instance. The figure below is an example of the M-Bus device and the table below provides information on the fields contained in that section:
| + | |
| | | |
| ===Devices=== | | ===Devices=== |
| ---- | | ---- |
| + | |
| + | To add new device to configuration press <b>Add</b> button which is shown below. |
| | | |
| [[File:Networking_rutos_manual_mbus_client_devices_add.png|border|class=tlt-border]] | | [[File:Networking_rutos_manual_mbus_client_devices_add.png|border|class=tlt-border]] |
| + | |
| + | |
| + | |
| + | The Devices section is used to configure the general device instance. The figure below is an example of the M-Bus device and the table below provides information on the fields contained in that section: |
| + | |
| + | [[File:Networking_rutos_manual_mbus_client_device_configuration.png|border|class=tlt-border]] |
| | | |
| <table class="nd-mantable"> | | <table class="nd-mantable"> |
Line 83: |
Line 89: |
| ===Data collecting groups=== | | ===Data collecting groups=== |
| ---- | | ---- |
| + | |
| + | To reach data collecting groups configuration press <b>Edit</b> button as shown below. |
| | | |
| [[File:Networking_rutos_manual_mbus_client_data_collecting_groups.png|border|class=tlt-border]] | | [[File:Networking_rutos_manual_mbus_client_data_collecting_groups.png|border|class=tlt-border]] |
| + | |
| + | |
| | | |
| Before saving, you can check if your configuration works accordingly by pressing the Test Configuration button. You should see the data in a pop-up field. | | Before saving, you can check if your configuration works accordingly by pressing the Test Configuration button. You should see the data in a pop-up field. |
Line 119: |
Line 129: |
| | | |
| | | |
| + | |
| + | To reach group values configuration press <b>Edit</b> button as shown below. |
| | | |
| [[File:Networking_rutos_manual_mbus_client_data_collecting_groups_value_edit.png|border|class=tlt-border]] | | [[File:Networking_rutos_manual_mbus_client_data_collecting_groups_value_edit.png|border|class=tlt-border]] |
Line 173: |
Line 185: |
| ---- | | ---- |
| | | |
− | The M-Bus device configuration section is used to configure the general service functionality. The figure below is an example of the M-Bus Settings and the table below provides information on the fields contained in that section: | + | The M-Bus device configuration section is used to configure the general service functionality. The figure below is an example of the M-Bus Settings and the table below provides information on the fields contained in that section: |
| | | |
| [[File:Networking rutos manual mbus gateway mbus device configuration.png|border|class=tlt-border]] | | [[File:Networking rutos manual mbus gateway mbus device configuration.png|border|class=tlt-border]] |
Line 194: |
Line 206: |
| </tr> | | </tr> |
| </table> | | </table> |
− |
| |
− |
| |
| | | |
| ===Configuration settings=== | | ===Configuration settings=== |
| ---- | | ---- |
| + | |
| + | This is just a simplified way of configuring Over IP settings and the table below provides information on the fields contained in that section: |
| | | |
| [[File:Networking_rutos_manual_mbus_gateway_configuration_settings_general.png|border|class=tlt-border]] | | [[File:Networking_rutos_manual_mbus_gateway_configuration_settings_general.png|border|class=tlt-border]] |
Line 330: |
Line 342: |
| </tr> | | </tr> |
| </table> | | </table> |
− |
| |
| | | |
| | | |
| ===IP filter=== | | ===IP filter=== |
| ---- | | ---- |
| + | |
| + | The IP Filter section is used for configuring which network is allowed to communicate with the device. You may add a new instance by selecting the Interface and pressing Add. |
| | | |
| [[File:Networking_rutos_manual_mbus_gateway_ip_filter.png|border|class=tlt-border]] | | [[File:Networking_rutos_manual_mbus_gateway_ip_filter.png|border|class=tlt-border]] |