Changes

no edit summary
Line 1: Line 1: −
<p style="color:red">The information in this page is updated in accordance with firmware version '''[https://wiki.teltonika-networks.com/view/FW_%26_SDK_Downloads 00.07.03.3]'''.  
+
<p style="color:red">The information in this page is updated in accordance with firmware version '''[https://wiki.teltonika-networks.com/view/FW_%26_SDK_Downloads 00.07.08]'''.  
    
==Summary==
 
==Summary==
Line 20: Line 20:  
* Press '''Add'''
 
* Press '''Add'''
   −
[[File:Modbusupdategateway1.png|1000px|border|class=tlt-border]]
+
[[File:RutOS_RUT_Modbus_Gateway_7.8_add_instnace.png|1000px|border|class=tlt-border]]
    
A new window will open, where the device should be configured according to these steps:
 
A new window will open, where the device should be configured according to these steps:
Line 27: Line 27:  
* '''Listening IP''' – IP interface on which you are listening for incoming connections (input 0.0.0.0 to listen on any IP address)
 
* '''Listening IP''' – IP interface on which you are listening for incoming connections (input 0.0.0.0 to listen on any IP address)
 
* '''Port''' – Port number for Modbus gateway (default port is 502)
 
* '''Port''' – Port number for Modbus gateway (default port is 502)
* '''Slave ID''' configuration type – User defined or obtained from TCP
+
* '''Server ID''' – preconfigured Server ID number
* '''Slave ID''' – preconfigured Slave ID number
      
You may need to change configuration depending on your needs, just make sure that identical settings are set here and in RTU simulator: Baud rate, data bits, parity, stop bits, flow control.
 
You may need to change configuration depending on your needs, just make sure that identical settings are set here and in RTU simulator: Baud rate, data bits, parity, stop bits, flow control.
   −
[[File:Navigateandenable.png|700px|border|class=tlt-border]]
+
[[File:RutOS_RUT_Modbus_Gateway_7.8_instance_config.png|700px|border|class=tlt-border]]
    
In IP filter options on the bottom of the page, add IP addresses that will be allowed to reach your Modbus gateway (input 0.0.0.0/0 to allow any IP address).
 
In IP filter options on the bottom of the page, add IP addresses that will be allowed to reach your Modbus gateway (input 0.0.0.0/0 to allow any IP address).
   −
[[File:Ipfilter1.png|border|class=tlt-border]]
+
[[File:RutOS_RUT_Modbus_Gateway_7.8_instance_ip_filter.png|border|class=tlt-border]]
    
After finishing the configuration, press '''Save & Apply'''. With a setup like this, you will be able to send data from Modbus TCP to Modbus RTU.
 
After finishing the configuration, press '''Save & Apply'''. With a setup like this, you will be able to send data from Modbus TCP to Modbus RTU.