Go back to '''Services → Modbus → Modbus Serial Client''' and press [[File:Networking edit button fw76 v1.png]] button on the previously created '''Modbus''' slave '''Device''' instance or create a new one. In the opened window scroll down to the bottom and in Alarms Configuration section press [[File:Add Button.png|60x90px]]. | Go back to '''Services → Modbus → Modbus Serial Client''' and press [[File:Networking edit button fw76 v1.png]] button on the previously created '''Modbus''' slave '''Device''' instance or create a new one. In the opened window scroll down to the bottom and in '''Alarms Configuration''' section press [[File:Add Button.png|60x90px]]. | ||
In Alarm Configuration apply the following changes: | |||
In | |||
<table class="nd-othertables_2"> | |||
<tr> | |||
<th width=330; style="border-bottom: 1px solid white;></th> | |||
<th width=800; style="border-bottom: 1px solid white"; rowspan=2>[[File:Modbus Serial RUT955 10.png|border|class=tlt-border|850x600px|left]]</th> | |||
</tr> | |||
<tr> | |||
<td style="border-bottom: 4px solid white> | |||
# '''Enable''' instance. | |||
# Select '''Function''' (Read Holding Registers). | |||
# Write '''Register''' (1). | |||
# Select '''Condition''' (More than). | |||
# Write '''Value''' (10). | |||
# Select '''Action frequency''' (First trigger) | |||
# Select '''Action''' (SMS). | |||
# Create '''Message''' (type anything you want to receive). | |||
# Write '''Phone number''' (the number you want to receive the messages to). | |||
# Press [[File:Networking save apply button fw76 v1.png|100x35px]] button. | |||
</td> | |||
</tr> | |||
</table> | |||
[[File:Modbus serial rut955 13.png|border|class=tlt-border|1100x700px]] | [[File:Modbus serial rut955 13.png|border|class=tlt-border|1100x700px]] | ||
[[File:Modbus Serial RUT955 9.png|border|class=tlt-border|900x600px]] | [[File:Modbus Serial RUT955 9.png|border|class=tlt-border|900x600px]] |