Line 1: |
Line 1: |
| + | <p style="color:red">The information on this page is updated in accordance with [https://wiki.teltonika-networks.com/view/FW_%26_SDK_Downloads'''00.07.03.2'''] firmware version.</p> |
| + | |
| ==Introduction== | | ==Introduction== |
− |
| |
− | <p style="color:red">The information on this page is updated in accordance with [https://wiki.teltonika-networks.com/view/FW_%26_SDK_Downloads'''00.07.03.2'''] firmware version. .</p>
| |
| | | |
| '''Modbus''' is a serial communications protocol. Simple and robust, it has become a de facto standard communication protocol and is now a commonly available means of connecting industrial electronic devices. | | '''Modbus''' is a serial communications protocol. Simple and robust, it has become a de facto standard communication protocol and is now a commonly available means of connecting industrial electronic devices. |
Line 40: |
Line 40: |
| Lets continue with the configuration, now we will configure Modbus TCP Master on the same device. Navigate to '''Services → Modbus → Modbus TCP Master'''. Press the button '''ADD''' and follow the steps provided below: | | Lets continue with the configuration, now we will configure Modbus TCP Master on the same device. Navigate to '''Services → Modbus → Modbus TCP Master'''. Press the button '''ADD''' and follow the steps provided below: |
| | | |
− | [[File:Networking rut configuration modbus tcp master v2.png|border|class=tlt-border|1100px]] | + | [[File:Networking rut configuration modbus tcp master v3.png|border|class=tlt-border|1100px]] |
| | | |
| '''Explanation:''' | | '''Explanation:''' |
Line 96: |
Line 96: |
| | | |
| * '''30 30''' - equals to 00(+ symbol) | | * '''30 30''' - equals to 00(+ symbol) |
− | * '''33 37 30 36 78 78 78 31 35 39 34''' - equals to 3706xxx1594 number | + | * '''33 37 30 36 78 78 78 31 35 39 34''' - equals to 3706xxx1594 number (keep in mind that 78 in hex equals '''x''' symbol, this whole part has to be changed in accordance to your phone number) |
| * '''00 00 00 00 00 00 00''' - our number only takes up to 3 registers(4 symbols = 1 register), all other registers will be filled with 0 value | | * '''00 00 00 00 00 00 00''' - our number only takes up to 3 registers(4 symbols = 1 register), all other registers will be filled with 0 value |
| * '''74 65 73 74''' - equals to 'test' in HEX | | * '''74 65 73 74''' - equals to 'test' in HEX |
Line 126: |
Line 126: |
| Execute the first request, if everything was configurated correctly you should receive the confirmation message after that execute the '''Test_send''' request which will send the message to your phone number. | | Execute the first request, if everything was configurated correctly you should receive the confirmation message after that execute the '''Test_send''' request which will send the message to your phone number. |
| | | |
− | [[File:Networking rut configuration modbus tcp master send request test v1.png|border|class=tlt-border|1100px]] | + | [[File:Networking rut configuration modbus tcp master send request test v2.png|border|class=tlt-border|1100px]] |
| + | |
| + | |
| + | ---- |
| + | '''The example of message received:''' |
| + | |
| + | [[File:Networking rut configuration modbus tcp master send request test meessage v1.jpg|border|class=tlt-border|500px]] |
| | | |
| ==References== | | ==References== |
Line 132: |
Line 138: |
| * '''https://wiki.teltonika-networks.com/view/RUT955_Modbus#Set_Parameters''' Modbus Set Parameters manual | | * '''https://wiki.teltonika-networks.com/view/RUT955_Modbus#Set_Parameters''' Modbus Set Parameters manual |
| * '''https://www.utilities-online.info/ascii-to-hex''' ASCII to HEX converter | | * '''https://www.utilities-online.info/ascii-to-hex''' ASCII to HEX converter |
| + | [[Category:Modbus]] |