Template:Networking rut manual modbus: Difference between revisions
Template:Networking rut manual modbus (view source)
Revision as of 11:09, 24 October 2023
, 24 October 2023Text replacement - "\{\{Template: Networking_rutos_manual_fw_disclosure (.*) (.*) (.*) (.*) \}\}" to "{{Template: Networking_device_manual_fw_disclosure | series = {{{series}}} | name = {{{name}}} | fw_version ={{Template: Networking_device_manual_latest_fw | series = {{{series}}} | name = {{{name}}} }} }}"
No edit summary |
Gytispieze (talk | contribs) m (Text replacement - "\{\{Template: Networking_rutos_manual_fw_disclosure (.*) (.*) (.*) (.*) \}\}" to "{{Template: Networking_device_manual_fw_disclosure | series = {{{series}}} | name = {{{name}}} | fw_version ={{Template: Networking_device_manual_latest_fw | series = {{{series}}} | name = {{{name}}} }} }}") Tags: Mobile edit Mobile web edit |
||
(39 intermediate revisions by 8 users not shown) | |||
Line 1: | Line 1: | ||
{{Template: Networking_device_manual_fw_disclosure | |||
| series = {{{series}}} | |||
| name = {{{name}}} | |||
| fw_version ={{Template: Networking_device_manual_latest_fw | |||
| series = {{{series}}} | |||
| name = {{{name}}} | |||
}} | |||
}} | |||
==Summary== | ==Summary== | ||
<b>Modbus</b> is a serial communications protocol. Simple and robust, it has become a de facto standard communication protocol and is now a commonly available means of connecting industrial electronic | <b>Modbus</b> is a serial communications protocol. Simple and robust, it has become a de facto standard communication protocol and is now a commonly available means of connecting industrial electronic devices. | ||
{{ | This chapter of the user manual provides an overview of the Modbus page for {{{name}}} devices. | ||
}} | |||
==Modbus TCP== | ==Modbus TCP== | ||
Line 13: | Line 19: | ||
The figure below is an example of the Modbus TCP window section and the table below provides information on the fields contained in that window: | The figure below is an example of the Modbus TCP window section and the table below provides information on the fields contained in that window: | ||
[[File: | [[File:Networking_rut_manual_modbus_modbus_tcp.png|border|class=tlt-border]] | ||
<table class="nd-mantable"> | |||
| | <tr> | ||
| | <th>Field</th> | ||
<th>Value</th> | |||
<th>Description</th> | |||
</tr> | |||
<tr> | |||
<td>Enable</td> | |||
<td>yes | no; default: <b>none</b></td> | |||
<td>Turns Modbus TCP on or off.</td> | |||
</tr> | |||
<tr> | |||
<td>Port</td> | |||
<td>integer [0..65535]; default: '''502'''</td> | |||
<td>TCP port used for Modbus communications.</td> | |||
</tr> | |||
<tr> | |||
<td>Device ID</td> | |||
<td>integer [0..255]; default: <b>1</b></td> | |||
<td>The device's Modbus slave ID. When set to 0, it will respond to requests addressed to any ID.</td> | |||
</tr> | |||
<tr> | |||
<td>Allow Remote Access</td> | |||
<td>yes | no; default: <b>no</b></td> | |||
<td>Allows remote Modbus connections by adding an exception to the device's firewall on the port specified in the field above.</td> | |||
</tr> | |||
<tr> | |||
<td>Keep persistent connection</td> | |||
<td>yes | no; default: <b>no</b></td> | |||
<td>If enabled, the connection will not be closed after each completed Modbus request.</td> | |||
</tr> | |||
<tr> | |||
<td>Connection timeout</td> | |||
<td>integer [1..60]; default: <b>0</b></td> | |||
<td>Timeout in seconds after which the connection will be closed. Use <b>0</b> to use default value provided by Operating System.</td> | |||
</tr> | |||
<tr> | |||
<td>Enable custom register block</td> | |||
<td>yes | no; default: <b>no</b></td> | |||
<td>Allow custom register block</td> | |||
</tr> | |||
</table> | |||
===Get Parameters=== | ===Get Parameters=== | ||
Line 24: | Line 68: | ||
Modbus parameters are held within <b>registers</b>. Each register contains 2 bytes of information. For simplification, the number of registers for storing numbers is 2 (4 bytes), while the number of registers for storing text information is 16 (32 bytes). The register numbers and corresponding system values are described in the table below: | Modbus parameters are held within <b>registers</b>. Each register contains 2 bytes of information. For simplification, the number of registers for storing numbers is 2 (4 bytes), while the number of registers for storing text information is 16 (32 bytes). The register numbers and corresponding system values are described in the table below: | ||
<br> <br> | <br> <br> | ||
{{#ifeq: {{{series}}} | | {{#ifeq: {{{series}}} | RUT2XX | ||
| {{Template: Networking_{{lc:{{{series}}}}}_manual_modbus_modbus_tcp_get_parameters_table}} | | {{Template: Networking_{{lc:{{{series}}}}}_manual_modbus_modbus_tcp_get_parameters_table}} | ||
| {{Template: Networking_{{lc:{{{name}}}}}_manual_modbus_modbus_tcp_get_parameters_table}} | | {{Template: Networking_{{lc:{{{name}}}}}_manual_modbus_modbus_tcp_get_parameters_table}} | ||
}} | }} | ||
{{#ifeq: {{{series}}} | | {{#ifeq: {{{series}}} | RUT2XX | ||
| {{Template: Networking_device_manual_modbus_modbus_tcp_get_parameters_table_asterisk}} | | {{Template: Networking_device_manual_modbus_modbus_tcp_get_parameters_table_asterisk}} | ||
| | | | ||
Line 35: | Line 79: | ||
---- | ---- | ||
The Modbus daemon can also set some device parameters. These parameters and explanations on how to use them are described in the table below: | The Modbus daemon can also set some device parameters. These parameters and explanations on how to use them are described in the table below: | ||
<br> <br> | <br><br> | ||
{{#ifeq: {{{series}}} | | {{#ifeq: {{{series}}} | RUT2XX | ||
| {{Template: Networking_{{lc:{{{series}}}}}_manual_modbus_modbus_tcp_set_parameters_table}} | | {{Template: Networking_{{lc:{{{series}}}}}_manual_modbus_modbus_tcp_set_parameters_table}} | ||
| {{Template: Networking_{{lc:{{{name}}}}}_manual_modbus_modbus_tcp_set_parameters_table}} | | {{Template: Networking_{{lc:{{{name}}}}}_manual_modbus_modbus_tcp_set_parameters_table}} | ||
Line 49: | Line 93: | ||
==Modbus TCP Master== | ==Modbus TCP Master== | ||
A Modbus <b>master</b> device can request data from Modbus slaves. The Modbus TCP Master section is used to configure Modbus TCP slaves. | A Modbus <b>master</b> device can request data from Modbus slaves. The Modbus TCP Master section is used to configure Modbus TCP slaves. | ||
You can create a maximum of 10 slave configurations. | You can create a maximum of 10 slave configurations. | ||
Line 81: | Line 100: | ||
The figure below is an example of the <b>Slave device configuration</b> and the table below provides information on the fields contained in that section: | The figure below is an example of the <b>Slave device configuration</b> and the table below provides information on the fields contained in that section: | ||
[[File: | [[File:Networking_rut_manual_modbus_modbus_tcp_master_slave_device_configuration.png|border|class=tlt-border]] | ||
<table class="nd-mantable"> | <table class="nd-mantable"> | ||
Line 116: | Line 135: | ||
<tr> | <tr> | ||
<td>Period</td> | <td>Period</td> | ||
<td>integer [1..6400]; default: <b> | <td>integer [1..6400]; default: <b>60</b></td> | ||
<td>Interval at which requests are sent to the slave device.</td> | <td>Interval at which requests are sent to the slave device.</td> | ||
</tr> | </tr> | ||
<tr> | <tr> | ||
<td>Timeout</td> | <td>Timeout</td> | ||
<td>integer [1..30]; default: <b> | <td>integer [1..30]; default: <b>5</b></td> | ||
<td>Maximum response wait time.</td> | <td>Maximum response wait time.</td> | ||
</tr> | </tr> | ||
Line 128: | Line 147: | ||
===Requests configuration=== | ===Requests configuration=== | ||
---- | ---- | ||
A Modbus <b>request</b> is way of obtaining data from Modbus slaves. The master sends a request to a slave specifying | A Modbus <b>request</b> is a way of obtaining data from Modbus slaves. The master sends a request to a slave specifying the function code to be performed. The slave then sends the requested data back to the Modbus master. You can create a maximum of 64 request configurations for each slave device. | ||
The figure below is an example of the Requests configuration section and the table below provides information contained in the fields of that section: | The figure below is an example of the Requests configuration section and the table below provides information contained in the fields of that section: | ||
[[File: | [[File:Networking_rut_manual_modbus_modbus_tcp_master_request_configuration.png|border|class=tlt-border]] | ||
<table class="nd-mantable"> | <table class="nd-mantable"> | ||
Line 147: | Line 166: | ||
<tr> | <tr> | ||
<td>Data type</td> | <td>Data type</td> | ||
<td>8bit INT | 8bit UINT | 16bit INT, high byte first | 16bit INT, low byte first | 16bit UINT, high byte first | 16bit UINT, low byte first | 32bit float, Byte order 1,2,3,4 | 32bit float, Byte order 4,3,2,1 | 32bit float, Byte order 2,1,4,3 | 32bit float, Byte order 3,4,1,2; default: <b>16bit INT, high byte first</b></td> | <td>Hex | Ascii | 8bit INT | 8bit UINT | 16bit INT, high byte first | 16bit INT, low byte first | 16bit UINT, high byte first | 16bit UINT, low byte first | 32bit float, Byte order 1,2,3,4 | 32bit float, Byte order 4,3,2,1 | 32bit float, Byte order 2,1,4,3 | 32bit float, Byte order 3,4,1,2; default: <b>16bit INT, high byte first</b></td> | ||
<td>How read data will be stored.</td> | <td>How read data will be stored.</td> | ||
</tr> | </tr> | ||
Line 168: | Line 187: | ||
<tr> | <tr> | ||
<td>First Register</td> | <td>First Register</td> | ||
<td>integer [ | <td>integer [1..65536]; default: <b>1</b></td> | ||
<td>First Modbus register from which data will be read.</td> | <td>First Modbus register number from which data will be read.<br>'''Note''' - {{{series}}} Modbus Master uses register numbers, which value is +1 higher than address value.</br></td> | ||
</tr> | </tr> | ||
<tr> | <tr> | ||
Line 200: | Line 219: | ||
===Alarm configuration=== | ===Alarm configuration=== | ||
---- | ---- | ||
<b>Alarms</b> are way of setting up automated actions when some Modbus values meet user specified conditions. The figure below is an example of the Alarm configuration page and the table below provides information on fields that it contains: | <b>Alarms</b> are a way of setting up automated actions when some Modbus values meet user specified conditions. The figure below is an example of the Alarm configuration page and the table below provides information on fields that it contains: | ||
{{#ifeq:{{{series}}}|RUT2XX|[[File:Networking_rut2xx_manual_modbus_modbus_tcp_master_alarm_configuration.png|border|class=tlt-border]] | |||
|[[File:Networking_rut_manual_modbus_modbus_tcp_master_alarm_configuration.png|border|class=tlt-border]] | |||
}} | |||
<table class="nd-mantable"> | <table class="nd-mantable"> | ||
Line 237: | Line 258: | ||
<tr> | <tr> | ||
<td>Action</td> | <td>Action</td> | ||
<td>SMS | Trigger output | Modbus Request; default: <b>SMS</b></td> | <td><span style="color: #f0632c; font-weight:bold;">SMS</span> | <span style="color: red; font-weight:bold;">Trigger output</span> | <span style="color: purple; font-weight:bold;">Modbus Request</span>; default: <b>SMS</b></td> | ||
<td>Action that will be taken if the condition is met. Possible actions: | <td>Action that will be taken if the condition is met. Possible actions: | ||
<ul> | <ul> | ||
Line 247: | Line 268: | ||
</tr> | </tr> | ||
<tr> | <tr> | ||
<td><span style="color: # | <td><span style="color: #f0632c;">SMS:</span> Message</td> | ||
<td>string; default: <b>none</b></td> | <td>string; default: <b>none</b></td> | ||
<td>SMS message text.</td> | <td>SMS message text.</td> | ||
</tr> | </tr> | ||
<tr> | <tr> | ||
<td><span style="color: # | <td><span style="color: #f0632c;">SMS:</span> Phone number</td> | ||
<td>phone number; default: <b>none</b></td> | <td>phone number; default: <b>none</b></td> | ||
<td>Recipient's phone number.</td> | <td>Recipient's phone number.</td> | ||
</tr> | </tr> | ||
<tr> | <tr> | ||
<td><span style="color: red;">Trigger output: | <td><span style="color: red;">Trigger output:</span> Output</td>{{#ifeq:{{{name}}}|RUT955| | ||
<td>Open collector output | <td>Open collector output {{!}} Relay output {{!}} Both; default: <b>Open collector output</b></td>| | ||
<td>4PIN output; default: <b>4PIN output</b></td>}} | |||
<td>Which output(s) will be triggered.</td> | <td>Which output(s) will be triggered.</td> | ||
</tr> | </tr> | ||
<tr> | <tr> | ||
<td><span style="color: red;">Trigger output: I/O Action | <td><span style="color: red;">Trigger output:</span> I/O Action</td> | ||
<td>Turn On | Turn Off | Invert; default: <b>Turn On</b></td> | <td>Turn On | Turn Off | Invert; default: <b>Turn On</b></td> | ||
<td>Action that will taken on the specified output.</td> | <td>Action that will taken on the specified output.</td> | ||
</tr> | </tr> | ||
<tr> | <tr> | ||
<td><span style="color: purple;">Modbus Request: | <td><span style="color: purple;">Modbus Request:</span> IP address</td> | ||
<td>ip | host; default: <b>none</b></td> | <td>ip | host; default: <b>none</b></td> | ||
<td>Modbus slave's IP address.</td> | <td>Modbus slave's IP address.</td> | ||
</tr> | </tr> | ||
<tr> | <tr> | ||
<td><span style="color: purple;">Modbus Request: | <td><span style="color: purple;">Modbus Request:</span> Port</td> | ||
<td>integer [0..65535]; default: <b>none</b></td> | <td>integer [0..65535]; default: <b>none</b></td> | ||
<td>Modbus slave's port.</td> | <td>Modbus slave's port.</td> | ||
</tr> | </tr> | ||
<tr> | <tr> | ||
<td><span style="color: purple;">Modbus Request: | <td><span style="color: purple;">Modbus Request:</span> Timeout</td> | ||
<td>integer [1..30]; default: <b>5</b></td> | <td>integer [1..30]; default: <b>5</b></td> | ||
<td>Maximum time to wait for a response.</td> | <td>Maximum time to wait for a response.</td> | ||
</tr> | </tr> | ||
<tr> | <tr> | ||
<td><span style="color: purple;">Modbus Request: | <td><span style="color: purple;">Modbus Request:</span> ID</td> | ||
<td>integer [1..255]; default: <b>none</b></td> | <td>integer [1..255]; default: <b>none</b></td> | ||
<td>Modbus slave ID.</td> | <td>Modbus slave ID.</td> | ||
</tr> | </tr> | ||
<tr> | <tr> | ||
<td><span style="color: purple;">Modbus Request: | <td><span style="color: purple;">Modbus Request:</span> Modbus function</td> | ||
<td>Read Coil Status (1) | Read Input Status (2) | Read Holding Registers (3) | Read Input Registers (4) | Force Single Coil (5) | Preset Single Register (6) | Force Multiple Coils (15) | Force Multiple Registers (16); default: <b>Force Single Coil (5)</b></td> | <td>Read Coil Status (1) | Read Input Status (2) | Read Holding Registers (3) | Read Input Registers (4) | Force Single Coil (5) | Preset Single Register (6) | Force Multiple Coils (15) | Force Multiple Registers (16); default: <b>Force Single Coil (5)</b></td> | ||
<td>A function code specifies the type of register being addressed by a Modbus request.</td> | <td>A function code specifies the type of register being addressed by a Modbus request.</td> | ||
</tr> | </tr> | ||
<tr> | <tr> | ||
<td><span style="color: purple;">Modbus Request: | <td><span style="color: purple;">Modbus Request:</span> First register</td> | ||
<td>integer [0..65535]; default: <b>none</b></td> | <td>integer [0..65535]; default: <b>none</b></td> | ||
<td>Begins reading from the register specified in this field.</td> | <td>Begins reading from the register specified in this field.</td> | ||
</tr> | </tr> | ||
<tr> | <tr> | ||
<td><span style="color: purple;">Modbus Request: | <td><span style="color: purple;">Modbus Request:</span> Number of registers</td> | ||
<td>integer [0..65535]; default: <b>none</b></td> | <td>integer [0..65535]; default: <b>none</b></td> | ||
<td>The number of registers that will be read from the first register.</td> | <td>The number of registers that will be read from the first register.</td> | ||
Line 303: | Line 325: | ||
</table> | </table> | ||
{{#ifeq:{{{ | {{#ifeq: {{{serial}}} | 1 | | ||
| | ==Modbus Serial Master== | ||
| | |||
| | The <b>Modbus Serial Master</b> page is used to configure the router as a Modbus RTU master. Modbus RTU (remote terminal unit) is a serial communication protocol mainly used in communication via RS232 or RS485 serial interfaces. | ||
| | |||
===RS232=== | |||
---- | |||
This section is used to configure the Modbus RTU master's RS232 serial interface settings. Refer to the figure and table below for information on RS232 configuration. | |||
[[File:Networking_rut_manual_modbus_modbus_serial_master_rs232.png|border|class=tlt-border]] | |||
<table class="nd-mantable"> | |||
<tr> | |||
<th>Field</th> | |||
<th>Value</th> | |||
<th>Description</th> | |||
</tr> | |||
<tr> | |||
<td>Enabled</td> | |||
<td>yes {{!}} no; default: <b>no</b></td> | |||
<td>Turns Modbus RTU via RS232 on or off.</td> | |||
</tr> | |||
<tr> | |||
<td>Baud rate</td> | |||
<td>300 {{!}} 1200 {{!}} 2400 {{!}} 4800 {{!}} 9600 {{!}} 19200 {{!}} 38400 {{!}} 57600 {{!}} 115200; default: <b>115200</b></td> | |||
<td>Serial data transmission rate (in bits per second).</td> | |||
</tr> | |||
<tr> | |||
<td>Data bits</td> | |||
<td>5 {{!}} 6 {{!}} 7 {{!}} 8; default: <b>8</b></td> | |||
<td>Number of data bits for each character.</td> | |||
</tr> | |||
<tr> | |||
<td>Parity</td> | |||
<td>None {{!}} Even {{!}} Odd; default: <b>Even</b></td> | |||
<td>In serial transmission, parity is a method of detecting errors. An extra data bit is sent with each data character, arranged so that the number of 1 bits in each character, including the parity bit, is always odd or always even. If a byte is received with the wrong number of 1s, then it must have been corrupted. However, an even number of errors can pass the parity check. | |||
<ul> | |||
<li><b>None</b> (<b>N</b>) - no parity method is used.</li> | |||
<li><b>Odd</b> (<b>O</b>) - the parity bit is set so that the number of "logical ones (1s)" has to be odd.</li> | |||
<li><b>Even</b> (<b>E</b>) - the parity bit is set so that the number of "logical ones (1s)" has to be even.</li> | |||
</ul> | |||
</td> | |||
</tr> | |||
<tr> | |||
<td>Stop bits</td> | |||
<td>1 {{!}} 2; default: <b>1</b></td> | |||
<td>Stop bits sent at the end of every character allow the receiving signal hardware to detect the end of a character and to resynchronise with the character stream. Electronic devices usually use one stop bit. Two stop bits are required if slow electromechanical devices are used.</td> | |||
</tr> | |||
<tr> | |||
<td>Flow control</td> | |||
<td>None {{!}} RTS/CTS {{!}} Xon/Xoff; default: <b>None</b></td> | |||
<td>In many circumstances a transmitter might be able to send data faster than the receiver is able to process it. To cope with this, serial lines often incorporate a "handshaking" method, usually distinguished between hardware and software handshaking. | |||
<ul> | |||
<li><b>RTS/CTS</b> - hardware handshaking. RTS and CTS are turned OFF and ON from alternate ends to control data flow, for instance when a buffer is almost full.</li> | |||
<li><b>Xon/Xoff</b> - software handshaking. The Xon and Xoff characters are sent by the receiver to the sender to control when the sender will send data, i.e., these characters go in the opposite direction to the data being sent. The circuit starts in the "sending allowed" state. When the receiver's buffers approach capacity, the receiver sends the Xoff character to tell the sender to stop sending data. Later, after the receiver has emptied its buffers, it sends an Xon character to tell the sender to resume transmission.</li> | |||
</ul> | |||
</td> | |||
</tr> | |||
</table> | |||
===RS485=== | |||
---- | |||
This section is used to configure the Modbus RTU master's RS485 serial interface settings. Refer to the figure and table below for information on RS485 configuration. | |||
[[File:Networking_rut_manual_modbus_modbus_serial_master_rs485.png|border|class=tlt-border]] | |||
<table class="nd-mantable"> | |||
<tr> | |||
<th>Field</th> | |||
<th>Value</th> | |||
<th>Description</th> | |||
</tr> | |||
<tr> | |||
<td>Enabled</td> | |||
<td>yes {{!}} no; default: <b>no</b></td> | |||
<td>Turns Modbus RTU via RS485 on or off.</td> | |||
</tr> | |||
<tr> | |||
<td>Baud rate</td> | |||
<td>300 {{!}} 1200 {{!}} 2400 {{!}} 4800 {{!}} 9600 {{!}} 19200 {{!}} 38400 {{!}} 57600 {{!}} 115200; default: <b>115200</b></td> | |||
<td>Serial data transmission rate (in bits per second).</td> | |||
</tr> | |||
<tr> | |||
<td>Data bits</td> | |||
<td>5 {{!}} 6 {{!}} 7 {{!}} 8; default: <b>8</b></td> | |||
<td>Number of data bits for each character.</td> | |||
</tr> | |||
<tr> | |||
<td>Parity</td> | |||
<td>None {{!}} Even {{!}} Odd; default: <b>Even</b></td> | |||
<td>In serial transmission, parity is a method of detecting errors. An extra data bit is sent with each data character, arranged so that the number of 1 bits in each character, including the parity bit, is always odd or always even. If a byte is received with the wrong number of 1s, then it must have been corrupted. However, an even number of errors can pass the parity check. | |||
<ul> | |||
<li><b>None</b> (<b>N</b>) - no parity method is used.</li> | |||
<li><b>Odd</b> (<b>O</b>) - the parity bit is set so that the number of "logical ones (1s)" has to be odd.</li> | |||
<li><b>Even</b> (<b>E</b>) - the parity bit is set so that the number of "logical ones (1s)" has to be even.</li> | |||
</ul> | |||
</td> | |||
</tr> | |||
<tr> | |||
<td>Stop bits</td> | |||
<td>1 {{!}} 2; default: <b>1</b></td> | |||
<td>Stop bits sent at the end of every character allow the receiving signal hardware to detect the end of a character and to resynchronise with the character stream. Electronic devices usually use one stop bit. Two stop bits are required if slow electromechanical devices are used.</td> | |||
</tr> | |||
<tr> | |||
<td>Flow control</td> | |||
<td>None {{!}} RTS/CTS {{!}} Xon/Xoff; default: <b>None</b></td> | |||
<td>In many circumstances a transmitter might be able to send data faster than the receiver is able to process it. To cope with this, serial lines often incorporate a "handshaking" method, usually distinguished between hardware and software handshaking. | |||
<ul> | |||
<li><b>RTS/CTS</b> - hardware handshaking. RTS and CTS are turned OFF and ON from alternate ends to control data flow, for instance when a buffer is almost full.</li> | |||
<li><b>Xon/Xoff</b> - software handshaking. The Xon and Xoff characters are sent by the receiver to the sender to control when the sender will send data, i.e., these characters go in the opposite direction to the data being sent. The circuit starts in the "sending allowed" state. When the receiver's buffers approach capacity, the receiver sends the Xoff character to tell the sender to stop sending data. Later, after the receiver has emptied its buffers, it sends an Xon character to tell the sender to resume transmission.</li> | |||
</ul> | |||
</td> | |||
</tr> | |||
</table> | |||
===Slaves=== | |||
---- | |||
The <b>Slaves</b> section is used to configure new Modbus slave devices. A Modbus slave is an entity that can be called upon by a Modbus master in order to obtain some type of information from it. | |||
To create a new Modbus slave, enter a custom name for it and click the 'Add' button. Then click the 'Edit' button next to the slave in order to enter its configuration window. | |||
====Slave settings==== | |||
---- | |||
The <b>Settings</b> section is used to configure the main parameters of the Modbus slave. Refer to the figure and table below for additional information. | |||
[[File:Networking_rut_manual_modbus_modbus_serial_master_slave_device_configuration.png|border|class=tlt-border]] | |||
<table class="nd-mantable"> | |||
<tr> | |||
<th>Field</th> | |||
<th>Value</th> | |||
<th>Description</th> | |||
</tr> | |||
<tr> | |||
<td>Enabled</td> | |||
<td>yes {{!}} no; default: <b>no</b></td> | |||
<td>Turns the slave on or off.</td> | |||
</tr> | |||
<tr> | |||
<td>Slave ID</td> | |||
<td>integer [1..255]; default: <b>1</b></td> | |||
<td>Slave ID. Each slave in a network is assigned a unique identifier ranging from 1 to 255. When the master requests data from a slave, the first byte it sends is the Slave ID.</td> | |||
</tr> | |||
<tr> | |||
<td>Frequency settings period</td> | |||
<td>Period {{!}} Schedule; default: <b>Period</b></td> | |||
<td>Specifies whether request frequency should happen every x amount of seconds (<i>Period</i>) or on a set schedule (<i>Schedule</i>).</td> | |||
</tr> | |||
<tr> | |||
<td>Period/Schedule</td> | |||
<td>integer [1..9999]/; default: <b>10</b></td> | |||
<td>Interval (in minutes) at which requests are sent to the slave device. Or Shedule (crontab-like, three fields (HH MM SS); e.g.. <i>0,12 * *</i>).</td> | |||
</tr> | |||
</table> | |||
====Slave requests==== | |||
---- | |||
A Modbus <b>request</b> is a way of obtaining data from Modbus slaves. The master sends a request to a slave specifying the function code to be performed. The slave then sends the requested data back to the Modbus master. | |||
The figure below is an example of the Requests configuration section and the table below provides information contained in the fields of that section: | |||
[[File:Networking_rut_manual_modbus_modbus_serial_master_request_configuration.png|border|class=tlt-border]] | |||
<table class="nd-mantable"> | |||
<tr> | |||
<th>Field</th> | |||
<th>Value</th> | |||
<th>Description</th> | |||
</tr> | |||
<tr> | |||
<td>Enabled</td> | |||
<td>yes {{!}} no; default: <b>no</b></td> | |||
<td>Turns the request on or off.</td> | |||
</tr> | |||
<tr> | |||
<td>Function</td> | |||
<td>Read Coil {{!}} Read Discrete Input {{!}} Read Holding Registers {{!}} Read Input Registers; default: <b>Read Holding Registers</b></td> | |||
<td>Modbus function used in Modbus request.</td> | |||
</tr> | |||
<tr> | |||
<td>First Register</td> | |||
<td>integer [1..65536]; default: <b>1</b></td> | |||
<td>First Modbus register from which data will be read.</td> | |||
</tr> | |||
<tr> | |||
<td>Number of Registers</td> | |||
<td>integer [1..2000]; default: <b>none</b></td> | |||
<td>Number of Modbus registers that will be read during the request/</td> | |||
</tr> | |||
</table> | |||
====Slave alarms==== | |||
---- | |||
<b>Alarms</b> are a way of setting up automated actions when some Modbus values meet user specified conditions. The figure below is an example of the Alarm configuration page and the table below provides information on fields that it contains: | |||
[[File:Networking_rut_manual_modbus_modbus_serial_master_alarm_configuration.png|border|class=tlt-border]] | |||
<table class="nd-mantable"> | |||
<tr> | |||
<th>Field</th> | |||
<th>Value</th> | |||
<th>Description</th> | |||
</tr> | |||
<tr> | |||
<td>Enabled</td> | |||
<td>yes {{!}} no; default: <b>no</b></td> | |||
<td>Turns the alarm on or off.</td> | |||
</tr> | |||
<tr> | |||
<td>Function</td> | |||
<td>Read Coil {{!}} Read Discrete Input {{!}} Read Holding Registers {{!}} Read Input Registers; default: <b>Read Holding Registers</b></td> | |||
<td>Modbus function used in Modbus request.</td> | |||
</tr> | |||
<tr> | |||
<td>Register</td> | |||
<td>integer [1..65536]; default: <b>1</b></td> | |||
<td>Number of the Modbus coil/input/holding register/input register that will be read.</td> | |||
</tr> | |||
<tr> | |||
<td>Condition</td> | |||
<td>More than {{!}} Less than {{!}} Equal to {{!}} Not equal to; default: <b>More than</b></td> | |||
<td>When a value is obtained it will be compared against the value specified in the following field. The comparison will be made in accordance with the condition specified in this field.</td> | |||
</tr> | |||
<tr> | |||
<td>Value</td> | |||
<td>integer [0..65535]; default: <b>0</b></td> | |||
<td>The value against which the read data will be compared.</td> | |||
</tr> | |||
<tr> | |||
<td>Action</td> | |||
<td>SMS {{!}} Trigger output {{!}} Modbus request; default: <b>SMS</b></td> | |||
<td>Action that will be taken if the condition is met. Possible actions: | |||
<ul> | |||
<li><b>SMS</b> - sends and SMS message to a specified recipient(s).</li> | |||
<li><b>Trigger output</b> - changes the state of a specified output(s).</li> | |||
<li><b>Modbus Request</b> - sends a Modbus request to a specified slave.</li> | |||
</ul> | |||
</td> | |||
</tr> | |||
</table> | |||
|}} | |}} | ||
==Modbus Data to Server== | ==Modbus Data to Server== | ||
Line 316: | Line 571: | ||
The Modbus <b>Data to Server</b> function provides you with the possibility to set up senders that transfer data collected from Modbus slaves to remote servers. To add a new data sender, enter the server's address, specify the data sending period and click the "Add" button: | The Modbus <b>Data to Server</b> function provides you with the possibility to set up senders that transfer data collected from Modbus slaves to remote servers. To add a new data sender, enter the server's address, specify the data sending period and click the "Add" button: | ||
[[File: | [[File:Networking_rut_manual_modbus_modbus_data_to_server_new_modbus_data_sender.png]] | ||
===Data sender configuration=== | ===Data sender configuration=== | ||
---- | ---- | ||
When you add a new data sender, you will be redirected to its configuration window. The figure below is an example of that window and the table below provides information on the fields that it contains: | When you add a new data sender, you will be redirected to its configuration window. | ||
The figure below is an example of that window and the table below provides information on the fields that it contains: | |||
[[File: | [[File:Networking_rut_manual_modbus_modbus_data_to_server_data_sender_configuration.png|border|class=tlt-border]] | ||
<table class="nd-mantable"> | <table class="nd-mantable"> | ||
<tr> | <tr> | ||
<th> | <th>Field</th> | ||
<th>yes | no; Default: <b>no</b></ | <th>Value</th> | ||
< | <th>Description</th> | ||
</tr> | |||
<tr> | |||
<td>Enabled</td> | |||
<td>yes | no; Default: <b>no</b></td> | |||
<td>Turns the data sender ON or OFF</td> | |||
</tr> | </tr> | ||
<tr> | <tr> | ||
Line 337: | Line 598: | ||
<tr> | <tr> | ||
<td>Protocol</td> | <td>Protocol</td> | ||
<td>HTTP(S); Default: <b>HTTP(S)</b></td> | <td><span style="color:#fb4828; font-weight:bold;">HTTP(S)</span> | <span style="color:#217979; font-weight:bold;">MQTT</span>; Default: <b>HTTP(S)</b></td> | ||
<td>Data sending protocol</td> | <td>Data sending protocol</td> | ||
</tr> | </tr> | ||
Line 347: | Line 608: | ||
<tr> | <tr> | ||
<td>Segment count</td> | <td>Segment count</td> | ||
<td>1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10; Default: <b>1</b></td> | <td>1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | All; Default: <b>1</b></td> | ||
<td>Max segment count in one JSON string sent to server</td> | <td>Max segment count in one JSON string sent to server.</td> | ||
</tr> | </tr> | ||
<tr> | <tr> | ||
<td>URL</td> | <td>URL / Host / Connection string</td> | ||
<td>host | ip; Default: <b>none</b></td> | <td>host | ip; Default: <b>none</b></td> | ||
<td>Address of the server to which the data will be sent | <td>Address of the server to which the data will be sent.<br><b>Important note</b>: when using HTTPS, remember to add the <b><i>https://</i></b> prefix before the URL.</td> | ||
</tr> | </tr> | ||
<tr> | <tr> | ||
Line 361: | Line 622: | ||
</tr> | </tr> | ||
<tr> | <tr> | ||
<td>Data filtering</td> | <td><span style="color:#fb4828;">HTTP(S): </span>Data filtering</td> | ||
<td>All data | By slave ID | By slave IP; Default: <b>All data</b></td> | <td>All data | By slave ID | By slave IP; Default: <b>All data</b></td> | ||
<td>Which data this sender will transfer to the server</td> | <td>Which data this sender will transfer to the server</td> | ||
</tr> | </tr> | ||
<tr> | <tr> | ||
<td>Retry on fail</td> | <td><span style="color:#fb4828;">HTTP(S): </span>Retry on fail</td> | ||
<td>yes | no; Default: <b>no</b></td> | <td>yes | no; Default: <b>no</b></td> | ||
<td>Specifies whether the data sender should retry failed attempts</td> | <td>Specifies whether the data sender should retry failed attempts</td> | ||
</tr> | </tr> | ||
<tr> | <tr> | ||
<td>Custom header</td> | <td><span style="color:#fb4828;">HTTP(S): </span>Custom header</td> | ||
<td>string; Default: <b>no</b></td> | <td>string; Default: <b>no</b></td> | ||
<td>Adds a custom header(s) to HTTP requests</td> | <td>Adds a custom header(s) to HTTP requests</td> | ||
</tr> | |||
<tr> | |||
<td><span style="color:#217979;">MQTT: </span>Port</td> | |||
<td>integer [0..65535]; Default: <b>none</b></td> | |||
<td>Port used to connect to host.</td> | |||
</tr> | |||
<tr> | |||
<td><span style="color:#217979;">MQTT: </span>Keepalive</td> | |||
<td>integer [1..640]; Default: <b>none</b></td> | |||
<td>MQTT keepalive period in seconds.</td> | |||
</tr> | |||
<tr> | |||
<td><span style="color:#217979;">MQTT: </span>Topic</td> | |||
<td>string; Default: <b>none</b></td> | |||
<td>Write topic to which your data will be sent.</td> | |||
</tr> | |||
<tr> | |||
<td><span style="color:#217979;">MQTT: </span>QoS</td> | |||
<td>0 {{!}} 1 {{!}} 2; Default: <b>0</b></td> | |||
<td>This field defines the guarantee of delivery for specific message.<br>Possible values are: | |||
<li>At most once (0)</li> | |||
<li>At least once (1)</li> | |||
<li>Exactly once (2)</li></td> | |||
</tr> | |||
<tr> | |||
<td><span style="color:#217979;">MQTT: </span>Use TLS</td> | |||
<td>yes | no; Default: <b>no</b></td> | |||
<td>Turns TLS authentication on or off.</td> | |||
</tr> | |||
</table> | |||
==MQTT Gateway== | |||
The <b>MQTT Gateway</b> function is used to transfer Modbus data (send requests, receive responses) over MQTT. When it is enabled, the device (this {{{name}}}) subscribes to a REQUEST topic and publishes on a RESPONSE topic on a specified MQTT broker. It translates received MQTT message payload to a Modbus request and relays it to the specified Modbus TCP slave. | |||
When the MQTT Gateway receives a response from the slave, it translates it to an MQTT message and publishes it on the RESPONSE topic. | |||
[[File:Networking_rutos_manual_modbus_mqtt_gateway_scheme.png]] | |||
Below is an example of the MQTT Gateway page. Refer to the table for information on MQTT Gateway configuration fields. | |||
[[File:Networking_rut_manual_modbus_mqtt_gateway.png|border|class=tlt-border]] | |||
<table class="nd-mantable"> | |||
<tr> | |||
<th>Field</th> | |||
<th>Value</th> | |||
<th>Description</th> | |||
</tr> | |||
<tr> | |||
<td>Enable</td> | |||
<td>off <nowiki>|</nowiki> on; default: <b>off</b></td> | |||
<td>Turns MQTT gateway on or off.</td> | |||
</tr> | |||
<tr> | |||
<td>Host</td> | |||
<td>ip <nowiki>|</nowiki> host; default: <b>127.0.0.1</b></td> | |||
<td>IP address or hostname of an MQTT broker.</td> | |||
</tr> | |||
<tr> | |||
<td>Port</td> | |||
<td>integer [0..65535]; default: <b>1883</b></td> | |||
<td>Port number of the MQTT broker.</td> | |||
</tr> | |||
<tr> | |||
<td>Request topic</td> | |||
<td>string; default: <b>request</b></td> | |||
<td>MQTT topic for sending requests.</td> | |||
</tr> | |||
<tr> | |||
<td>Response topic</td> | |||
<td>string; default: <b>response</b></td> | |||
<td>MQTT topic for subscribing to responses.</td> | |||
</tr> | |||
<tr> | |||
<td>Username</td> | |||
<td>string; default: <b>none</b></td> | |||
<td>Username for authentication to the MQTT broker. Leave empty if you do not use client authentication.</td> | |||
</tr> | |||
<tr> | |||
<td>Password</td> | |||
<td>string; default: <b>none</b></td> | |||
<td>Password for authentication to the MQTT broker. Leave empty if you do not use client authentication.</td> | |||
</tr> | </tr> | ||
</table> | </table> | ||
===Request messages=== | |||
---- | |||
Modbus request data sent in the MQTT payload should be generated in accordance with the following format: | |||
<b>0 <COOKIE> <IP_TYPE> <IP> <PORT> <TIMEOUT> <SLAVE_ID> <MODBUS_FUNCTION> <REGISTER_NUMBER> <REGISTER_COUNT/VALUE></b> | |||
Explanation: | |||
<ul> | |||
<li><b>0</b> - must be 0, which signifies a textual format (currently the only one implemented).</li> | |||
<li><b>Cookie</b> - a 64-bit unsigned integer in range [0..2<sup>64</sup>]). A cookie is used in order to distinguish which response belongs to which request, each request and the corresponding response contain a matching cookie: a 64-bit unsigned integer.</li> | |||
<li><b>IP type</b> - host IP address type. Possible values: | |||
<ul> | |||
<li><b>0</b> - IPv4 address;</li> | |||
<li><b>1</b> - IPv6 address;</li> | |||
<li><b>2</b> - hostname that will be resolved to an IP address.</li> | |||
</ul></li> | |||
<li><b>IP</b> - IP address of a Modbus TCP slave. IPv6 must be presented in full form (e.g., <i>2001:0db8:0000:0000:0000:8a2e:0370:7334</i>).</li> | |||
<li><b>Port</b> - port number of the Modbus TCP slave.</li> | |||
<li><b>Timeout</b> - timeoutfor Modbus TCP connection, in seconds. Range [1..999].</li> | |||
<li><b>Slave ID</b> - Modbus TCP slave ID. Range [1..255].</li> | |||
<li><b>Modbus function</b> - Only these are supported at the moment: | |||
<ul> | |||
<li><b>3</b> - read holding registers;</li> | |||
<li><b>6</b> - write to a single holding register;</li> | |||
<li><b>16</b> - write to multiple holding registers.</li> | |||
</ul></li> | |||
<li><b>Register number</b> - number of the first register (in range [1..65536]) from which the registers will be read/written to. | |||
<li><b>Register count/value</b> - this value depends on the Modbus function: | |||
<ul> | |||
<li><b>3</b> - <u>register count</u> (in range [1..125]); must not exceed the boundary (first register number + register count <= 65537);</li> | |||
<li><b>6</b> - <u>register value</u> (in range [0..65535]);</li> | |||
<li><b>16</b> - <u>register count</u> (in range [1..123]); must not exceed the boundary (first register number + register count <= 65537); and <u>register values</u> separated with commas, without spaces (e.g., <i>1,2,3,654,21,789</i>); there must be exactly as many values as specified (with register count); each value must be in the range of [0..65535].</li> | |||
</ul></li> | |||
</ul> | |||
===Response messages=== | |||
---- | |||
A special response message can take one of the following forms: | |||
<COOKIE> OK - <i>for functions 6 and 16</i> | |||
<COOKIE> OK <VALUE> <VALUE> <VALUE>... - <i>for function 3, where <VALUE> <VALUE> <VALUE>... are read register values</i> | |||
<COOKIE> ERROR: ... - <i>for failures, where ... is the error description</i> | |||
===Examples=== | |||
---- | |||
Below are a few <b>examples</b> of controlling/monitoring the internal Modbus TCP Slave on {{{name}}}. | |||
---- | |||
<b>Reboot the device</b> | |||
<ul> | |||
<li>Request:<br><pre>0 65432 0 192.168.1.1 502 5 1 6 206 1</pre></li> | |||
<li>Response:<br><pre>65432 OK</pre></li> | |||
</ul> | |||
---- | |||
<b>Retrieve uptime</b> | |||
<ul> | |||
<li>Request:<br><pre>0 65432 0 192.168.1.1 502 5 1 3 2 2</pre></li> | |||
<li>Response:<br><pre>65432 OK 0 5590</pre></li> | |||
</ul> | |||
---- | |||
If you're using Eclipse Mosquitto (MQTT implementation used on {{{name}}}), Publish/Subscribe commands may look something like this: | |||
<b>Retrieve uptime</b> | |||
<ul> | |||
<li>Request:<br><pre>mosquitto_pub -h 192.168.1.1 -p 1883 -t request -m "0 65432 0 192.168.1.1 502 5 1 3 2 2"</pre></li> | |||
<li>Response:<br><pre>mosquitto_sub -h 192.168.1.1 -p 1883 -t response | |||
65432 OK 0 5590</pre></li> | |||
</ul> | |||
==See also== | ==See also== | ||
{{ | <ul> | ||
<li><b>[[{{{name}}} Monitoring via Modbus|Monitoring via Modbus]]</b> - detailed examples on how to use Modbus TCP</li> | |||
</ul> | |||
[[Category:{{{name}}} | [[Category:{{{name}}} Services section]] |