RUTX08 OPC UA Server: Difference between revisions
(Created page with "{{Template:Networking_rutos_manual_opcua_server <!------------------------DEVICE-----------------------> | name = RUTX08 | series = RUTX <!----------------------SEPARATORS--...") |
m (Vainius.l moved page Draft:RUTX08 OPC UA Server to RUTX08 OPC UA Server without leaving a redirect) |
||
(3 intermediate revisions by the same user not shown) | |||
Line 4: | Line 4: | ||
| series = RUTX | | series = RUTX | ||
<!----------------------SEPARATORS---------------------> | <!----------------------SEPARATORS---------------------> | ||
| digitalio = | | digitalio = 1 <!----------------------Digital inputoutput.---------------------> | ||
| configurableio = 0 <!----------------------Configurable | | configurableio = 0 <!----------------------Configurable inputoutput.---------------------> | ||
| relay = 0 | | relay = 0 | ||
| adc = 0 | | adc = 0 |
Latest revision as of 08:35, 2 January 2024
Main Page > RUTX Routers > RUTX08 > RUTX08 Manual > RUTX08 WebUI > RUTX08 Services section > RUTX08 OPC UA ServerThe information in this page is updated in accordance with firmware version RUTX_R_00.07.10.2.
Summary
OPC Unified Architecture (OPC UA) is a cross-platform, open-source, IEC62541 standard for data exchange from sensors to cloud applications developed by the OPC Foundation. The UA in OPC UA stands for “Unified Architecture” and refers to the latest specification of the standard. It differs from its predecessor in that it is platform-independent, moving away from COM/DCOM to purely binary TCP/IP or alternatively SOAP.
This manual page provides an overview of the OPC UA Server in RUTX08 devices.
Note: OPC UA Server is additional software that can be installed from the System → Package Manager page.
Status
This section displays OPC UA Server status information.
OPC UA Server Configuration
The OPC UA Server Configuration section is used to enable the local OPC UA server.
Field | Value | Description |
---|---|---|
Enable | off | on; default: off | Enables OPC UA server. |
Port | integer [1..65535]; default: none | Service port. |
OPC UA Server variables
All RUTOS device variables are described in the table below:
Note: All the variables have these qualities in common:
- Namespace index is 1
- Node ID type is string
- Read-only
- Updated upon request
ID | Type | Description |
---|---|---|
sys_uptime | UINT32 | System uptime in seconds. |
sys_serial | String | Device serial number. |
sys_devname | String | Device name. |
sys_devcode | String | Device code. |
sys_version | String | Firmware version. |
sys_hostname | String | Hostname. |
lan_mac | String | LAN MAC address. |
lan_ip | String | IP address of LAN interface. |
lan_mask | String | Subnet mask of LAN interface. |
lan_gateway | String | Gateway IP address of LAN interface. |
lan_dns | Array of String | IP addresses of LAN interface DNS servers. |
rut_wan_ip | String | IP address if WAN is connected. |
rut_wan_type | String | Values of WAN type. |
io_din | Array of BOOL | Values of digital input pins. |
io_dout | Array of BOOL | Values of digital output pins. |