RUT300 OPC UA Server: Difference between revisions

From Teltonika Networks Wiki
(Created page with "{{Template:Networking_rutos_manual_opcua_server <!------------------------DEVICE-----------------------> | name = RUT300 | series = RUT30X <!----------------------SEPARAT...")
 
m (Vainius.l moved page Draft:RUT300 OPC UA Server to RUT300 OPC UA Server without leaving a redirect)
 
(One intermediate revision by the same user not shown)
Line 1: Line 1:
{{Template:Networking_rutos_manual_opcua_server
{{Template:Networking_rutos_manual_opcua_server
<!------------------------DEVICE----------------------->
<!------------------------DEVICE----------------------->
| name  = RUT300
| name  = RUT300
| series = RUT30X
| series = RUT30X
<!----------------------SEPARATORS--------------------->
<!----------------------SEPARATORS--------------------->
| digitalio      = 0 <!----------------------Digital inputoutput.--------------------->
| digitalio      = 0 <!----------------------Digital inputoutput.--------------------->
| configurableio = 0 <!----------------------Configurable inputoutput.--------------------->
| configurableio = 1 <!----------------------Configurable inputoutput.--------------------->
| relay          = 0
| relay          = 0
| adc            = 0
| adc            = 0
| gps            = 0
| gps            = 0
| mobile        = 0
| mobile        = 0
}}
}}

Latest revision as of 08:35, 2 January 2024

Main Page > EOL Products > RUT300 > RUT300 Manual > RUT300 WebUI > RUT300 Services section > RUT300 OPC UA Server

The information in this page is updated in accordance with firmware version RUT30X_R_00.07.10.2.

Summary

OPC Unified Architecture (OPC UA) is a cross-platform, open-source, IEC62541 standard for data exchange from sensors to cloud applications developed by the OPC Foundation. The UA in OPC UA stands for “Unified Architecture” and refers to the latest specification of the standard. It differs from its predecessor in that it is platform-independent, moving away from COM/DCOM to purely binary TCP/IP or alternatively SOAP.


This manual page provides an overview of the OPC UA Server in RUT300 devices.

Note: OPC UA Server is additional software that can be installed from the System → Package Manager page.

Status

This section displays OPC UA Server status information.

OPC UA Server Configuration

The OPC UA Server Configuration section is used to enable the local OPC UA server.

Field Value Description
Enable off | on; default: off Enables OPC UA server.
Port integer [1..65535]; default: none Service port.


OPC UA Server variables

All RUTOS device variables are described in the table below:

Note: All the variables have these qualities in common:

  • Namespace index is 1
  • Node ID type is string
  • Read-only
  • Updated upon request
ID Type Description
sys_uptime UINT32 System uptime in seconds.
sys_serial String Device serial number.
sys_devname String Device name.
sys_devcode String Device code.
sys_version String Firmware version.
sys_hostname String Hostname.
lan_mac String LAN MAC address.
lan_ip String IP address of LAN interface.
lan_mask String Subnet mask of LAN interface.
lan_gateway String Gateway IP address of LAN interface.
lan_dns Array of String IP addresses of LAN interface DNS servers.
rut_wan_ip String IP address if WAN is connected.
rut_wan_type String Values of WAN type.
io_dio_dir Array of BOOL Directions of digital input/output pins. 0=IN, 1=OUT.
io_dio Array of BOOL Values of digital input/output pins.