Line 6: |
Line 6: |
| | | |
| __TOC__ | | __TOC__ |
− |
| |
− | ==2024.03.25: New PCB revision ==
| |
− | Starting from Q3 2024, RUT901 router will be manufactured with updated MAIN and RF PCB revisions.
| |
− |
| |
− | {| class="wikitable"
| |
− | |-
| |
− | | style="width: 1219px; text-align: left; background: #eeece1;" |PCN Number: PCN_New_PCB_Revision_2023.03.25<br>
| |
− | |-
| |
− | |}
| |
− |
| |
− | {| class="wikitable"
| |
− | |+
| |
− | ! colspan="3" style="text-align: left; background: #eeece1;" |Change description
| |
− | |-
| |
− | | style="text-align: left; background: white;" |Change type
| |
− | | style="text-align: left; background: white;" |Hardware change
| |
− | |-
| |
− | | style="width: 221px; text-align: left; background: white;" | Detailed description
| |
− | | style="width: 908px; text-align: left; background: white;" | Starting from Q3 2024, RUT901 router will be manufactured with updated MAIN and RF PCB revisions. The following are the detailed updates made to the MAIN and RF boards:
| |
− | * Added SIM card presence triggers to SoC GPIO
| |
− | * Added shift register clearing circuitry
| |
− | *Added pull-down resistors on pins to address potential issues that may arise when shift registers are in the tri-state high-z state.
| |
− | Please note that this change will be implemented gradually, throughout a 3-month transitional period starting from Q2, 2024. During this period, your shipments of RUT901 may consist of either the current packaging or the new one described above.
| |
− | |-
| |
− | | style="text-align: left; background: white;" | Change reasons
| |
− | | style="text-align: left; background: white;" | Hardware design improvements
| |
− | |-
| |
− | |}
| |
− |
| |
− | {| class="wikitable"
| |
− | |+
| |
− | ! style="text-align: left; background: #eeece1;" colspan="3" | Affected products information
| |
− | |-
| |
− | | style="width: 221px; text-align: left; background: white;" | Model
| |
− | | style="width: 448px; text-align: left; background: white;" | Affected order codes
| |
− | | style="width: 448px; text-align: left; background: white;" | Order code changes
| |
− | |-
| |
− | | style="text-align: left; background: white;" | RUT901
| |
− | | style="text-align: left; background: white;" | RUT901 *****
| |
− | | style="text-align: left; background: white;" | No changes
| |
− | |-
| |
− | | style="text-align: left; background: white;" | Upcoming change date
| |
− | | style="text-align: left; background: white;" colspan="2" | Q3 2024
| |
− | |-
| |
− | |}
| |
− |
| |
− | {| class="wikitable"
| |
− | |+
| |
− | ! style="text-align: left; background: #eeece1;" colspan="3" | Change impact
| |
− | |-
| |
− | | style="width: 221px; text-align: left; background: white;" |Risk assessment
| |
− | | colspan="2" style="width: 908px; text-align: left; background: white;" |No risk factors have been identified during the evaluation of this change. However, it is recommended to conduct an independent review to ensure alignment with specific circumstances and requirements.
| |
− | |-
| |
− | | style="text-align: left; background: white;" | Suggested implementation plan
| |
− | | colspan="2" style="text-align: left; background: white;" |
| |
− | The information included in this PCN will help adapt to the upcoming changes. For more detailed information, please get in touch with your sales representative.
| |
− | |-
| |
− | |}
| |
− |
| |
− | {| class="wikitable"
| |
− | |+
| |
− | ! style="width: 1141px; text-align: left; background: #eeece1;" colspan="3" | Acknowledgement of PCN receipt
| |
− | |-
| |
− | | style="text-align: left; background: white;" colspan="3"| If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above.
| |
− | |-
| |
− | |}
| |
− |
| |
− | To download the pdf version of this notification, [[Media:PCN_RUT901_2024_03_25_EN.pdf|click here]].
| |
| | | |
| {{Template:PCN_RutOS_7.7 | | {{Template:PCN_RutOS_7.7 |