Difference between revisions of "Template:Networking rutos manual modbus modbus tcp set parameters table rut2 rut9"
From Teltonika Networks Wiki
(Created page with "===Set Parameters=== ---- The Modbus daemon can also set some device parameters. <br> <br> <table class="nd-othertables"> <tr> <th width="300">value to set</th>...") |
(Created page with "===Set Parameters=== ---- The Modbus daemon can also set some device parameters. <br> <br> <table class="nd-othertables"> <tr> <th width="300">value to set</th>...") |
(No difference)
|
Latest revision as of 16:06, 8 April 2024
Set Parameters
The Modbus daemon can also set some device parameters.
value to set | register address | register number | register value | description |
---|---|---|---|---|
Hostname | 7 | 8 | Hostname (in decimal form) | Changes hostname |
Device name | 71 | 72 | Device name (in decimal form) | Changes device name |
Reboot | 206 | 207 | 1 | Reboots the router |
Switch PIN 3 state | 324 | 325 | 1|0 | Toggles PIN 3 ON or OFF, when output is selected |
Switch PIN 4 state | 325 | 326 | 1|0 | Toggles PIN 4 ON or OFF, when output is selected |
Switch PIN 3 direction | 326 | 327 | 1|0 | Toggles PIN 3 direction between INPUT (0) or OUTPUT (1) |
Switch PIN 4 direction | 327 | 328 | 1|0 | Toggles PIN 4 direction between INPUT (0) or OUTPUT (1) |
Change LAN IP | 394 | 395 | IPv4 (in decimal form) | Changes device LAN IP |