Difference between revisions of "Template:Networking rutos manual serial utilities"

From Teltonika Networks Wiki
(Renewed)
Line 8: Line 8:
 
}}
 
}}
  
{{#ifeq: {{{series}}} | RUT9 |<i><b>Note</b>: <b>[[{{{name}}} RS232/RS485 (legacy WebUI)#RS232|click here]]</b> for the old style WebUI (FW version {{Template: Networking_device_manual_latest_fw | series = RUT9XX}} and earlier) user manual page.</i>|}}
+
{{#ifeq: {{{series}}}| RUT9 |<i><b>Note</b>: <b>[[{{{name}}} RS232/RS485 (legacy WebUI)#RS232|click here]]</b> for the old style WebUI (FW version {{Template: Networking_device_manual_latest_fw | series = RUT9XX}} and earlier) user manual page.</i>|}}
 
==Summary==
 
==Summary==
  
Line 351: Line 351:
 
     <tr>
 
     <tr>
 
         <td>Device</td>
 
         <td>Device</td>
         <td>{{Template: Networking_rutos_manual_serial_ports | rs232={{{rs232}}} | rs485={{{rs485}}} | usb={{{usb}}} }}; default: <b>{{Template: Networking_rutos_manual_default_serial_port | rs232={{{rs232}}} | rs485={{{rs485}}} | usb={{{usb}}} }}</b></td>
+
         <td>{{#ifeq:{{{default}}}|mbus|MBUS| {{Template: Networking_rutos_manual_serial_ports | rs232={{{rs232}}} | rs485={{{rs485}}} | usb={{{usb}}} }}}}; default: <b>{{#ifeq:{{{default}}}|mbus|MBUS| {{Template: Networking_rutos_manual_default_serial_port | rs232={{{rs232}}} | rs485={{{rs485}}} | usb={{{usb}}} }}}}</b></td>
 
         <td>Specifies which serial port will be used for serial communication.</td>
 
         <td>Specifies which serial port will be used for serial communication.</td>
 
     </tr>
 
     </tr>
Line 440: Line 440:
 
     <tr>
 
     <tr>
 
       <td>Stop bits</td>
 
       <td>Stop bits</td>
       <td>1 {{!}} 2; default: <b>1</b></td>
+
       <td>{{#switch: {{{name}}} | TRB143 = 1; default: <b>1</b>  | #default = 1 {{!}} 2; default: <b>1</b> }}</td>
 
       <td>Stop bits sent at the end of every character allow the receiving signal hardware to detect the end of a character and to resynchronise with the character stream. Electronic devices usually use one stop bit. Two stop bits are required if slow electromechanical devices are used.</td>
 
       <td>Stop bits sent at the end of every character allow the receiving signal hardware to detect the end of a character and to resynchronise with the character stream. Electronic devices usually use one stop bit. Two stop bits are required if slow electromechanical devices are used.</td>
 
     </tr>
 
     </tr>
 
     <tr>
 
     <tr>
 
     <td>Parity</td>
 
     <td>Parity</td>
         <td>None {{!}} Odd {{!}} Even {{!}} Mark {{!}} Space; default: <b>None</b></td>
+
         <td>{{#switch: {{{name}}} | TRB143 = Even {{!}} default: Even | #default = None {{!}} Odd {{!}} Even {{!}} Mark {{!}} Space; default: <b>None</b> }}</td>
 
         <td>In serial transmission, parity is a method of detecting errors. An extra data bit is sent with each data character, arranged so that the number of 1 bits in each character, including the parity bit, is always odd or always even. If a byte is received with the wrong number of 1s, then it must have been corrupted. However, an even number of errors can pass the parity check.
 
         <td>In serial transmission, parity is a method of detecting errors. An extra data bit is sent with each data character, arranged so that the number of 1 bits in each character, including the parity bit, is always odd or always even. If a byte is received with the wrong number of 1s, then it must have been corrupted. However, an even number of errors can pass the parity check.
 
             <ul>
 
             <ul>
Line 480: Line 480:
 
You can configure network related parameters of the serial connection in the <b>Over IP Configuration</b> secion.
 
You can configure network related parameters of the serial connection in the <b>Over IP Configuration</b> secion.
  
[[File:Networking rutos manual serial utilities over ip mbus configuration general_v1.png|border|class=tlt-border]]
+
[[File:Networking rutos manual serial utilities over ip mbus configuration general_v2.png|border|class=tlt-border]]
  
 
<table class="nd-mantable">
 
<table class="nd-mantable">

Revision as of 15:32, 6 May 2024

The information in this page is updated in accordance with firmware version .


Summary

The Serial Utilities page is used to make serial communication configurations of different types. This manual page provides an overview of the Serial Utilities page in {{{name}}} devices.



Console

Console mode requires no further configuration than the settings above and is used as a direct-access method to the device's shell interface. For this purpose you may want use such applications as PuTTY on Windows and microcom, minicom, picocom or similar applications on Linux.

[[File:Networking_rutos_manual_serial_utilities_console_default_{{{default}}}_v1.png|border|class=tlt-border]]

Field Value Description
Enable off | on; default: off Turns the instance on or off.
Name string; default: none Instance name, generated by the user when first creating the configuration.
Device ; default: Specifies which serial port will be used for serial communication.
Baud rate integer [300..3000000]; default: 9600 Data rate for serial data transmission (in bits per second (bps)).
Data bits 8; default: 8 Number of data bits for each character.
Stop bits 1 | 2; default: 1 Stop bits sent at the end of every character allow the receiving signal hardware to detect the end of a character and to resynchronize with the character stream. Electronic devices usually use one stop bit. Two stop bits are required if slow electromechanical devices are used.
Parity None | Odd | Even | Mark | Space; default: None In serial transmission, parity is a method of detecting errors. An extra data bit is sent with each data character, arranged so that the number of 1 bits in each character, including the parity bit, is always odd or always even. If a byte is received with the wrong number of 1s, then it must have been corrupted. However, an even number of errors can pass the parity check.
  • None (N) - no parity method is used.
  • Odd (O) - the parity bit is set so that the number of "logical ones (1s)" has to be odd.
  • Even (E) - the parity bit is set so that the number of "logical ones (1s)" has to be even.
Flow control None; default: None In many circumstances a transmitter might be able to send data faster than the receiver is able to process it. To cope with this, serial lines often incorporate a "handshaking" method, usually distinguished between hardware and software handshaking.

Over IP

The Over IP serial type is used to manage serial connections over a TCP/IP network.

Serial Device Configuration


Configure serial port communication parameters in the Serial Device Configuration section.

[[File:Networking_rutos_manual_serial_utilities_over_ip_serial_default_{{{default}}}_v2.png|border|class=tlt-border]]

Field Value Description
Enable off | on; default: off Turns the instance on or off.
Name string; default: none Instance name, generated by the user when first creating the configuration.
Device ; default: Specifies which serial port will be used for serial communication.
Baud rate integer [300..3000000]; default: 9600 Data rate for serial data transmission (in bits per second (bps)).
Data bits 8; default: 8 Number of data bits for each character.
Stop bits 1 | 2; default: 1 Stop bits sent at the end of every character allow the receiving signal hardware to detect the end of a character and to resynchronise with the character stream. Electronic devices usually use one stop bit. Two stop bits are required if slow electromechanical devices are used.
Parity None | Odd | Even | Mark | Space; default: None In serial transmission, parity is a method of detecting errors. An extra data bit is sent with each data character, arranged so that the number of 1 bits in each character, including the parity bit, is always odd or always even. If a byte is received with the wrong number of 1s, then it must have been corrupted. However, an even number of errors can pass the parity check.
  • None (N) - no parity method is used.
  • Odd (O) - the parity bit is set so that the number of "logical ones (1s)" has to be odd.
  • Even (E) - the parity bit is set so that the number of "logical ones (1s)" has to be even.
Flow control None; default: None In many circumstances a transmitter might be able to send data faster than the receiver is able to process it. To cope with this, serial lines often incorporate a "handshaking" method, usually distinguished between hardware and software handshaking.

Over IP Configuration Settings


You can configure network related parameters of the serial connection in the Over IP Configuration secion.

File:Networking rutos manual serial utilities over ip mbus configuration general v2.png

Field Value Description
Mode Server | Client | Client + server | Bidirect; default: Server This device's role in the connection:
  • Server - the device waits for incoming connections.
  • Client - the device initiates the connection.
  • Client + server - launches service in server and client(s) mode simultaneously.
  • Bidirect - acts as client by default but waits for incoming connections at the same time.
Protocol TCP | UDP; default: TCP Protocol used in the communication process.
Client: Destination address IP | Port; default: empty Specify server address and port for client to connect to. E.g first field for address second for port. 16 destination addresses are allowed.
Server: UDP: Predefined addresses IP | Port; default: empty Set predefined IP and port for UDP connection. E.g first field for address second for port.
Listening port [1..65535]; default: empty When enabled, all data will be transmitted transparently.

Networking rutos manual serial utilities over ip mbus configuration security v1.png

Field Value Description
Use TLS/SSL off | on; default: off Mark to use TLS/SSL for connection.
TLS version Support all | tlsv1.0 | tlsv1.1 | tlsv1.2 | tlsv1.3; default: Support all Minimum TLS version allowed to be used.
TLS type Certificate based | Pre-Shared-Key based; default: Certificate based Select the type of TLS encryption.
Require certificate off | on; default: on Demand certificate and key from peer and verify them against certificate authority.
Verify host off | on; default: off Check if the server certificates Common Name (CN) matches hostname to which client is connecting.
Certificate files from device off | on; default: off Choose this option if you want to select certificate files from device.
Certificate files can be generated <a class=link href="/system/admin/certificates/generation">here</a>.
Certificate file .crt file; default: none Upload certificate file.
Key file .key file; default: none Upload key file.
CA file .ca file; default: none Upload CA file.
Pre-Shared-Key string; default: none The pre-shared-key in hex format with no leading “0x”.
Identify string; default: none Specify the identity.

Networking rutos manual serial utilities over ip mbus configuration advanced v3.png

Field Value Description
Raw mode off | on; default: on When enabled, all data will be transmitted transparently.
Remove all zeros off | on; default: off When checked, indicates that the first hex zeros should be skipped.
Inactivity timeout integer [0..36000]; default: 300 Specifies period of time in seconds, where server connection must be inactive, to disconnect client. To disable timeout input 0.
Serial timeout integer [0..1000]; default: none Specifies the maximum milliseconds to wait for serial data.
Max clients integer [1..32]; default: 4 Specify how many clients are allowed to connect simultaneously.
TCP echo on | off; default: off Enable software TCP echo.
Close connections on | off; default: off Close TCP connections everytime data is sent or received (might result in serial data loss).
Keep alive on | off; default: off Enable keep alive.
Keep alive time integer [0..32000]; default: 0 Close TCP connections everytime data is sent or received (might result in serial data loss).
Keep alive interval integer [0..32000]; default: 0 The interval between subsequential keepalive probes.
Keep alive probes integer [0..32000]; default: 0 The number of unacknowledged probes.

IP Filter


The IP Filter section is used for configuring which network is allowed to communicate with the device. You may add a new instance by selecting the Interface and pressing Add.

Networking rutos manual console ip filter.png

Then enter the IP address and save.

Networking rutos manual console ip filter instance.png