Difference between revisions of "Template:Networking rutos manual modbus modbus tcp get parameters table"
From Teltonika Networks Wiki
Tag: Rollback |
|||
(One intermediate revision by the same user not shown) | |||
Line 284: | Line 284: | ||
{{#ifeq:{{{series}}}|TRB5|| | {{#ifeq:{{{series}}}|TRB5|| | ||
<tr> | <tr> | ||
− | <td>Mobile data received last | + | <td>Mobile data received last 7 days (SIM1)</td> |
<td>292</td> | <td>292</td> | ||
<td>293</td> | <td>293</td> | ||
Line 291: | Line 291: | ||
</tr> | </tr> | ||
<tr> | <tr> | ||
− | <td>Mobile data sent | + | <td>Mobile data sent 7 days (SIM1)</td> |
<td>294</td> | <td>294</td> | ||
<td>295</td> | <td>295</td> | ||
Line 298: | Line 298: | ||
</tr> | </tr> | ||
<tr> | <tr> | ||
− | <td>Mobile data received last | + | <td>Mobile data received last 30 days (SIM1)</td> |
<td>296</td> | <td>296</td> | ||
<td>297</td> | <td>297</td> | ||
Line 305: | Line 305: | ||
</tr> | </tr> | ||
<tr> | <tr> | ||
− | <td>Mobile data sent last | + | <td>Mobile data sent last 30 days (SIM1)</td> |
<td>298</td> | <td>298</td> | ||
<td>299</td> | <td>299</td> | ||
Line 373: | Line 373: | ||
</tr> | </tr> | ||
<tr> | <tr> | ||
− | <td>Mobile data received | + | <td>Mobile data received 7 days (SIM2)</td> |
<td>316</td> | <td>316</td> | ||
<td>317</td> | <td>317</td> | ||
Line 380: | Line 380: | ||
</tr> | </tr> | ||
<tr> | <tr> | ||
− | <td>Mobile data sent | + | <td>Mobile data sent 7 days (SIM2)</td> |
<td>318</td> | <td>318</td> | ||
<td>319</td> | <td>319</td> | ||
Line 387: | Line 387: | ||
</tr> | </tr> | ||
<tr> | <tr> | ||
− | <td>Mobile data received last | + | <td>Mobile data received last 30 days (SIM2)</td> |
<td>320</td> | <td>320</td> | ||
<td>321</td> | <td>321</td> | ||
Line 394: | Line 394: | ||
</tr> | </tr> | ||
<tr> | <tr> | ||
− | <td>Mobile data sent last | + | <td>Mobile data sent last 30 days (SIM2)</td> |
<td>322</td> | <td>322</td> | ||
<td>323</td> | <td>323</td> |
Revision as of 12:18, 13 May 2024
Get Parameters
Modbus parameters are held within registers. Each register contains 2 bytes of information. For simplification, the number of registers for storing numbers is 2 (4 bytes), while the number of registers for storing text information is 16 (32 bytes).
The register numbers and corresponding system values are described in the table below:
required value | register address | register number | number of registers | representation |
---|---|---|---|---|
System uptime | 1 | 2 | 2 | 32 bit unsigned integer |
System hostname | 7 | 8 | 16 | Text |
Router serial number | 39 | 40 | 16 | Text |
LAN MAC address | 55 | 56 | 16 | Text |
Router name | 71 | 72 | 16 | Text |
Current WAN IP address | 139 | 140 | 2 | 8 bit unsigned integer |
Digital non-isolated input | 324 | 325 | 1 | 16 bit unsigned integer |
Digital open collector output | 325 | 326 | 1 | 16 bit unsigned integer |
PIN 3 direction | 326 | 327 | 1 | 16 bit unsigned integer |
PIN 4 direction | 327 | 328 | 1 | 16 bit unsigned integer |
Unix timestamp | 364 | 365 | 2 | 32 bit unsigned integer |
Local ISO time | 366 | 367 | 12 | Text |
UTC time | 378 | 389 | 12 | Text |
LAN IP | 394 | 395 | 2 | 8 bit unsigned integer |