==2024.05.18: Hardware changes== | ==2024.05.18: Hardware changes== | ||
− | Starting from Q3 2024, all {{{name}}} devices will be manufactured with modifications to the RS485 RE/DE management hardware | + | Starting from Q3 2024, all {{{name}}} devices will be manufactured with modifications to the RS485 RE/DE management hardware. |
{| class="wikitable" | {| class="wikitable" | ||
Line 11: | Line 11: | ||
{| class="wikitable" | {| class="wikitable" | ||
|+ | |+ | ||
− | ! colspan=" | + | ! colspan="2" style="text-align: left; background: #eeece1;" |Change description |
|- | |- | ||
| style="text-align: left; background: white;" |Change type | | style="text-align: left; background: white;" |Change type | ||
− | | style="text-align: left; background: white; | + | | style="text-align: left; background: white;" |Hardware change |
|- | |- | ||
− | | style="width: 221px; text-align: left; background: white; | + | | style="width: 221px; text-align: left; background: white;" | Detailed description |
− | | style="width: 908px; text-align: left; background: white; | + | | style="width: 908px; text-align: left; background: white;" | In the latest hardware revision of the {{{name}}} device, changes have been made to enhance the management of RS485 signalling. {{{name}}} will require firmware version TRB1_R_00.07.06 or newer to ensure compatibility with the hardware changes and to maintain full functionality. |
− | + | '''Important Note:''' Due to hardware changes, downgrading to firmware versions below, RutOS TRB1_R_00.07.06 is no longer supported.<br> | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| style="text-align: left; background: white;" | Change reasons | | style="text-align: left; background: white;" | Change reasons | ||
− | | style="text-align: left; background: white; | + | | style="text-align: left; background: white;" | Enhancement of RS485 signaling management, ensuring more stability with larger quantity of devices connected. |
|- | |- | ||
|} | |} | ||
Line 64: | Line 50: | ||
* Devices with the new hardware changes will not support firmware versions below TRB1_R_00.07.06. | * Devices with the new hardware changes will not support firmware versions below TRB1_R_00.07.06. | ||
* Custom firmware built on previous SDK versions will also not be supported. | * Custom firmware built on previous SDK versions will also not be supported. | ||
− | '''Please note''': this product change notification does not affect any previous {{{name}}} devices, except new {{{name}}} devices | + | '''Please note''': this product change notification does not affect any previous {{{name}}} devices, except new {{{name}}} devices. |
|- | |- |
Revision as of 14:52, 24 May 2024
2024.05.18: Hardware changes
Starting from Q3 2024, all {{{name}}} devices will be manufactured with modifications to the RS485 RE/DE management hardware.
PCN Number: PCN_RS485_{{{name}}}_2024_05_18_EN |
Change description | |
---|---|
Change type | Hardware change |
Detailed description | In the latest hardware revision of the {{{name}}} device, changes have been made to enhance the management of RS485 signalling. {{{name}}} will require firmware version TRB1_R_00.07.06 or newer to ensure compatibility with the hardware changes and to maintain full functionality.
Important Note: Due to hardware changes, downgrading to firmware versions below, RutOS TRB1_R_00.07.06 is no longer supported. |
Change reasons | Enhancement of RS485 signaling management, ensuring more stability with larger quantity of devices connected. |
Affected products information | ||
---|---|---|
Model | Affected order codes | Order code changes |
{{{name}}} | {{{name}}} ****** | No changes |
Upcoming change date | 2024 Q3 |
Change impact | ||
---|---|---|
Risk assessment |
Please note: this product change notification does not affect any previous {{{name}}} devices, except new {{{name}}} devices. | |
Suggested implementation plan |
Information included in this PCN will help adapt to the upcoming changes. For more detailed information, please contact your sales representative. |
Acknowledgement of PCN receipt | ||
---|---|---|
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above. |
To download the pdf version of this notification, [[Media:{{{name}}}Missing.pdf|click here]].