Changes

no edit summary
Line 1: Line 1: −
{{Template: Networking_rutos_manual_fw_disclosure
+
{{Template: Networking_device_manual_fw_disclosure
| fw_version ={{Template: Networking_rutos_manual_latest_fw
+
| series = {{{series}}}
 +
| name  = {{{name}}}
 +
| fw_version ={{Template: Networking_device_manual_latest_fw
 
  | series = {{{series}}}
 
  | series = {{{series}}}
 
  | name  = {{{name}}}
 
  | name  = {{{name}}}
 
  }}
 
  }}
 
}}
 
}}
{{#ifeq: {{{series}}} | RUT9 |<br><i><b>Note</b>: <b>[[{{{name}}} IoT Platforms (legacy WebUI)|click here]]</b> for the old style WebUI (FW version {{Template: Networking_rutos_manual_latest_fw | series = RUT9XX}} and earlier) user manual page.</i>|}}
+
{{#ifeq: {{{series}}} | RUT9 |<br><i><b>Note</b>: <b>[[{{{name}}} IoT Platforms (legacy WebUI)|click here]]</b> for the old style WebUI (FW version {{Template: Networking_device_manual_latest_fw | series = RUT9XX}} and earlier) user manual page.</i>|}}
{{#ifeq: {{{series}}} | RUT2 |<br><i><b>Note</b>: <b>[[{{{name}}} IoT Platforms (legacy WebUI)|click here]]</b> for the old style WebUI (FW version {{Template: Networking_rutos_manual_latest_fw | series = RUT2XX}} and earlier) user manual page.</i>|}}
+
{{#ifeq: {{{series}}} | RUT2 |<br><i><b>Note</b>: <b>[[{{{name}}} IoT Platforms (legacy WebUI)|click here]]</b> for the old style WebUI (FW version {{Template: Networking_device_manual_latest_fw | series = RUT2XX}} and earlier) user manual page.</i>|}}
 
__TOC__
 
__TOC__
 
==Summary==
 
==Summary==
Line 14: Line 16:  
This chapter of the user manual provides an overview of the Cloud Solutions page for {{{name}}} devices.
 
This chapter of the user manual provides an overview of the Cloud Solutions page for {{{name}}} devices.
   −
<u><b>Note:</b> Each Cloud Solutions service, except RMS, is additional software that can be installed from the <b>Services → [[{{{name}}} Package Manager|Package Manager]]</b> page.</u>
+
<u><b>Note:</b> Each Cloud Solutions service, except RMS, is additional software that can be installed from the <b>System → [[{{{name}}} Package Manager|Package Manager]]</b> page.</u>
    
{{Template:Networking_rutos_manual_basic_advanced_webui_disclaimer
 
{{Template:Networking_rutos_manual_basic_advanced_webui_disclaimer
Line 28: Line 30:  
The figure below is a screenshot of the RMS section taken from a device which has been connected to RMS:
 
The figure below is a screenshot of the RMS section taken from a device which has been connected to RMS:
   −
[[File:Networking_rutos_manual_setup_wizard_rms_{{{rms}}}_v2.png|border|class=tlt-border]]
+
[[File:Networking_rutos_manual_setup_wizard_rms_{{{rms}}}_v4.png|border|class=tlt-border]]
    
<table class="nd-mantable">
 
<table class="nd-mantable">
Line 56: Line 58:  
         <td>integer [0..65535]; default: <b>15009</b></td>
 
         <td>integer [0..65535]; default: <b>15009</b></td>
 
         <td>Port number for connecting to RMS. If you're using regular RMS, just leave the default port (<i>15009</i>).</td>
 
         <td>Port number for connecting to RMS. If you're using regular RMS, just leave the default port (<i>15009</i>).</td>
 +
    </tr>
 +
    <tr>
 +
        <td>Authentication code</td>
 +
        <td>string; default: <b>none</b></td>
 +
        <td>Authentication code provided by RMS after adding the device.</td>
 
     </tr>
 
     </tr>
 
</table>
 
</table>
Line 63: Line 70:  
The RMS server waits for incoming connections. Since the device attempts to connect at a fixed interval, it may not connect instantly after you add it to RMS. While it is disconnected, you can check how much time is left until the next connection attempt in the Status section:
 
The RMS server waits for incoming connections. Since the device attempts to connect at a fixed interval, it may not connect instantly after you add it to RMS. While it is disconnected, you can check how much time is left until the next connection attempt in the Status section:
   −
[[File:Networking_rutos_manual_cloud_solutions_rms_disconnected_rms_{{{rms}}}_v2.png|border|class=tlt-border]]
+
[[File:Networking_rutos_manual_cloud_solutions_rms_disconnected_rms_{{{rms}}}_v5.png|border|class=tlt-border]]
 +
 
 +
To speed up the process by initiating an immediate connection attempt, click the <b>Connect</b> button.
   −
To speed up the process by initiating an immediate connection attempt, click the 'Connect' button.
+
[[File:Networking_rutos_manual_cloud_solutions_rms_connect_{{{rms}}}_v3.png|border|class=tlt-border]]
 +
 
 +
If a failure or unknown status occurs, there is an alternative to try to reconnect again, click the <b>Reconnect</b> button.
 +
 
 +
[[File:Networking_rutos_manual_cloud_solutions_rms_reconnect_{{{rms}}}_v3.png|border|class=tlt-border]]
 +
 
 +
When the device is already connected a <b>Reset</b> button becomes visible. Use it to terminate the device's connection to RMS.
 +
 
 +
[[File:Networking_rutos_manual_cloud_solutions_rms_unregister_{{{rms}}}_v3.png|border|class=tlt-border]]
    
For more information on Teltonika Networks Remote Management System (RMS) refer to the <b>[[RMS Manual]]</b> or <b>[[RMS FAQ]]</b> pages.
 
For more information on Teltonika Networks Remote Management System (RMS) refer to the <b>[[RMS Manual]]</b> or <b>[[RMS FAQ]]</b> pages.
Line 73: Line 90:  
<b>Azure IoT Hub</b> is Microsoft's ever-expanding set of cloud services to help your organization meet your business challenges. Azure IoT Hub is compatible with Teltonika Networks devices.
 
<b>Azure IoT Hub</b> is Microsoft's ever-expanding set of cloud services to help your organization meet your business challenges. Azure IoT Hub is compatible with Teltonika Networks devices.
   −
{{#ifeq: {{{modem}}} | 1 |
+
By default, the Azure IoT list is empty. To add a new connection, enter a custom name and click the 'Add' button.
The figure and table below provides explanations for Azure IoT Hub configuration parameters when selected 'Message Type' is <i>GSM values</i>.
     −
[[File:Networking_rutos_manual_cloud_solutions_azure_iot_hub_modem_1.png|border|class=tlt-border]]
+
[[File:Networking_rutos_manual_cloud_solutions_azure_iot_hub_add.png|border|class=tlt-border]]
 +
 
 +
===Modify Azure IoTHub===
 +
 
 +
[[File:Networking_rutos_manual_cloud_solutions_azure_iot_hub_modify.png|border|class=tlt-border]]
    
<table class="nd-mantable">
 
<table class="nd-mantable">
Line 85: Line 105:  
     </tr>
 
     </tr>
 
     <tr>
 
     <tr>
         <td>Enable Azure IoT Hub monitoring</td>
+
         <td>Enable</td>
         <td>off <nowiki>|</nowiki> on; default: <b>off</b></td>
+
         <td>off {{!}} on; default: <b>off</b></td>
         <td>Turns the Azure IoT Hub service on or off.</td>
+
         <td>Enable Azure IoT service.</td>
 
     </tr>
 
     </tr>
 
     <tr>
 
     <tr>
         <td>Connection string</td>
+
         <td>Name</td>
 
         <td>string; default: <b>none</b></td>
 
         <td>string; default: <b>none</b></td>
         <td>Unique connection string a.k.a. server address provided by the Azure Iot Hub service.</td>
+
         <td>Connection name.</td>
 
     </tr>
 
     </tr>
 
     <tr>
 
     <tr>
         <td>Message Type</td>
+
         <td>Enable Direct Methods</td>
         <td>GSM values <nowiki>|</nowiki> MQTT messages; default: <b>MQTT messages</b></td>
+
         <td>off {{!}} <span style="color:red">on</span>; default: <b>off</b></td>
         <td>Values that are to be sent to the Azure server.</td>
+
         <td>Enable Direct Method feature set.</td>
 
     </tr>
 
     </tr>
 
     <tr>
 
     <tr>
         <td>Message sending interval (sec.)</td>
+
         <td><span style="color:red">Device Model ID</span></td>
         <td>integer; default: <b>300</b></td>
+
         <td>string; default: <b>dtmi:Teltonika:genericDevice;1</b></td>
         <td>Device data sending frequency in seconds. Minimum value is 10 s.</td>
+
         <td>Model ID of the Digital Twins Definition Language.</td>
 
     </tr>
 
     </tr>
 
     <tr>
 
     <tr>
         <td>Mobile Interface</td>
+
         <td>Connection type</td>
         <td>mobile interface; default: <b>mobs1a1</b></td>
+
         <td>Shared Access Signature (SAS) key {{!}} <span style="color:blue">Device Provisioning Service (DPS)</span>; default: <b>Shared Access Signature (SAS) key</b></td>
         <td>Interface name for which IP address and sent/received bytes should be selected.</td>
+
         <td>Connection type to an existing IoT Hub.</td>
 
     </tr>
 
     </tr>
 
     <tr>
 
     <tr>
         <td>GSM Values</td>
+
         <td>Connection String</td>
         <td>IMSI <nowiki>|</nowiki> IP Address <nowiki>|</nowiki> RSRP <nowiki>|</nowiki> ICCID <nowiki>|</nowiki> Bytes received <nowiki>|</nowiki> Cell ID <nowiki>|</nowiki> RSCP <nowiki>|</nowiki> PIN state <nowiki>|</nowiki> Manufacturer <nowiki>|</nowiki> Bytes sent <nowiki>|</nowiki> RSRQ <nowiki>|</nowiki> Revision number <nowiki>|</nowiki> Serial number <nowiki>|</nowiki> ECIO <nowiki>|</nowiki> SINR <nowiki>|</nowiki>Data carrier type <nowiki>|</nowiki> Network link state <nowiki>|</nowiki> Operator <nowiki>|</nowiki> PIN count <nowiki>|</nowiki> Signal level <nowiki>|</nowiki> Model <nowiki>|</nowiki> Connection state <nowiki>|</nowiki> Temperature <nowiki>|</nowiki> IMEI <nowiki>|</nowiki> SIM card state; default: <b>none</b></td>
+
         <td>string; default: <b>none</b></td>
         <td>Selects the mobile connection values that to be sent to the Azure IoT Hub service.</td>
+
         <td>Connection string based on primary key used in API calls which allows device to communicate with IoT Hub.</td>
 
     </tr>
 
     </tr>
</table>|}}The figure and table below provides explanations for Azure IoT Hub configuration parameters{{#ifeq:{{{modem}}}|1| when selected 'Message Type' is <i>MQTT messages</i>|}}.
  −
  −
[[File:Networking_rutos_manual_cloud_solutions_azure_iot_hub_modem_0.png|border|class=tlt-border]]
  −
  −
<table class="nd-mantable">
   
     <tr>
 
     <tr>
         <th>Field</th>
+
         <td><span style="color:blue">ID Scope</span></td>
      <th>Value</th>
+
         <td>string; default: <b>none</b></td>
      <th>Description</th>
+
         <td>Unique identifier that is assigned to an Azure IoT Hub during its creation and is used to uniquely identify the specific provisioning service the device will register through.</td>
    </tr>
  −
    <tr>
  −
        <td>Enable Azure IoT Hub monitoring</td>
  −
         <td>off | on; default: <b>off</b></td>
  −
         <td>Turns the Azure IoT Hub service on or off.</td>
   
     </tr>
 
     </tr>
 
     <tr>
 
     <tr>
         <td>Connection string</td>
+
         <td><span style="color:blue">Registration ID</span></td>
 
         <td>string; default: <b>none</b></td>
 
         <td>string; default: <b>none</b></td>
         <td>Unique connection string a.k.a. server address provided by the Azure Iot Hub service.</td>
+
         <td>The registration ID is used to uniquely identify a device registration with the Device Provisioning Service.</td>
 
     </tr>
 
     </tr>
 
     <tr>
 
     <tr>
         <td>Message Type</td>
+
         <td><span style="color:blue">Global Device Endpoint</span></td>
         <td>{{#ifeq:{{{modem}}}|1|GSM values <nowiki>|</nowiki>|}} MQTT messages; default: <b>MQTT messages</b></td>
+
         <td>string; default: <b>global.azure-devices-provisioning.net</b></td>
         <td>Values that are to be sent to the Azure server.</td>
+
         <td>Destination for messages sent by IoT devices to the Azure IoT Hub.</td>
 
     </tr>
 
     </tr>
 
     <tr>
 
     <tr>
         <td>MQTT Host</td>
+
         <td><span style="color:blue">Attestation mechanism</span></td>
         <td>ip | host; default: <b>none</b></td>
+
         <td><span style="color:brown">X.509 certificates</span> {{!}} <span style="color:orange">Symmetric Key</span>; default: <b>X.509 certificates</b></td>
         <td>MQTT broker's IP address or hostname.</td>
+
         <td>Method used to confirm a device's identity in Device Provisioning Service.</td>
 
     </tr>
 
     </tr>
 
     <tr>
 
     <tr>
         <td>MQTT Port</td>
+
         <td><span style="color:brown">X.509 Certificate</span></td>
         <td>integer [0..65535]; default: <b>none</b></td>
+
         <td>-interactive button; default: <b></b></td>
         <td>MQTT broker's IP port number.</td>
+
         <td>Upload the "leaf" certificate file.</td>
 
     </tr>
 
     </tr>
 
     <tr>
 
     <tr>
         <td>Topic</td>
+
         <td><span style="color:brown">X.509 Private Key</span></td>
         <td>string; default: <b>none</b></td>
+
         <td>-interactive button; default: <b></b></td>
         <td>MQTT topic to be used for publishing the data.</td>
+
         <td>Upload the "leaf" key file.</td>
 
     </tr>
 
     </tr>
 
     <tr>
 
     <tr>
         <td>Username</td>
+
         <td><span style="color:orange">Symmetric Key</span></td>
 
         <td>string; default: <b>none</b></td>
 
         <td>string; default: <b>none</b></td>
         <td>Username used for authentication to the MQTT broker.</td>
+
         <td>The the derived device key from the DPS Primary Key.</td>
    </tr>
  −
    <tr>
  −
        <td>Password</td>
  −
        <td>string; default: <b>none</b></td>
  −
        <td>Password used for authentication to the MQTT broker.</td>
   
     </tr>
 
     </tr>
 
</table>
 
</table>
Line 170: Line 175:  
The <b>Cloud of Things</b> is an IoT cloud platform which provides the possibility to remotely monitor, manage and control your connected devices and machines – plug-and-play, without extensive installation.
 
The <b>Cloud of Things</b> is an IoT cloud platform which provides the possibility to remotely monitor, manage and control your connected devices and machines – plug-and-play, without extensive installation.
   −
[[File:Networking_rutos_manual_cloud_solutions_cloud_of_things_modem_{{{modem}}}.png|border|class=tlt-border]]
+
[[File:Networking_rutos_manual_cloud_solutions_cloud_of_things_v1.png|border|class=tlt-border]]
    
<table class="nd-mantable">
 
<table class="nd-mantable">
Line 192: Line 197:  
         <td>integer; default: <b>none</b></td>
 
         <td>integer; default: <b>none</b></td>
 
         <td>Push connection interval in minutes.</td>
 
         <td>Push connection interval in minutes.</td>
     </tr>{{#ifeq: {{{modem}}} | 1 |
+
     </tr>
    <tr>
  −
        <td>Mobile Interface</td>
  −
        <td>mobile interface; default: <b>mobs1a1</b></td>
  −
        <td>Interface name for which IP address and sent/received bytes should be selected.</td>
  −
    </tr>|}}
   
     <tr>
 
     <tr>
 
         <td>Reset Auth</td>
 
         <td>Reset Auth</td>
Line 211: Line 211:  
The figure and table below provide explanations for Cumulocity configuration parameters available on the device. For a detailed configuration guide, [[Cumulocity Configuration|click here]].
 
The figure and table below provide explanations for Cumulocity configuration parameters available on the device. For a detailed configuration guide, [[Cumulocity Configuration|click here]].
   −
[[File:Networking_rutos_manual_cloud_solutions_cumulocity_modem_{{{modem}}}.png|border|class=tlt-border]]
+
[[File:Networking_rutos_manual_cloud_solutions_cumulocity_v1.png|border|class=tlt-border]]
    
<table class="nd-mantable">
 
<table class="nd-mantable">
Line 238: Line 238:  
         <td>integer; default: <b>none</b></td>
 
         <td>integer; default: <b>none</b></td>
 
         <td>Connection push interval in minutes. This field defines how often the device will try to connect to the Cumulocity server.</td>
 
         <td>Connection push interval in minutes. This field defines how often the device will try to connect to the Cumulocity server.</td>
     </tr>{{#ifeq:{{{modem}}}|1|
+
     </tr>
    <tr>
  −
        <td>Mobile Interface</td>
  −
        <td>network interface; default: <b>mob1s1a1</b></td>
  −
        <td>Interface whose GSM parameters will be sent to the Cumulocity server for monitoring.</td>
  −
    </tr>|}}
   
     <tr>
 
     <tr>
 
         <td>Reset Auth</td>
 
         <td>Reset Auth</td>
Line 292: Line 287:  
     </tr>|}}
 
     </tr>|}}
 
</table>
 
</table>
{{#ifeq:{{{series}}}|RUTX|
+
{{#switch:{{{series}}}
 +
|RUTX|RUTM=
 
==Greengrass==
 
==Greengrass==
   Line 313: Line 309:  
         <td>Core-specific config file.</td>
 
         <td>Core-specific config file.</td>
 
     </tr>
 
     </tr>
</table>|}}
+
</table>
 +
|#default=}}
    
[[Category:{{{name}}} Services section]]
 
[[Category:{{{name}}} Services section]]