RUT361 Power Consumption: Difference between revisions

From Teltonika Networks Wiki
No edit summary
No edit summary
 
Line 1: Line 1:
RUT361 power consumption values in different states of operation are represented in the tables below:
'''Averaged''' RUT361 power consumption values in different states of operation are represented in the tables below:


<table class="nd-othertables_3">
<table class="nd-othertables_3">

Latest revision as of 09:39, 16 August 2024

Main Page > RUT Routers > RUT361 > RUT361 Manual > RUT361 Power Consumption

Averaged RUT361 power consumption values in different states of operation are represented in the tables below:

Test type
Current (mA)
Power consumption (W)
Idle, no SIM card inserted (9 V)
126
1.13
Idle, no SIM card inserted (12 V)
96
1.15
Idle, no SIM card inserted (24 V)
54
1.3


Test type
Current (mA)
Power consumption (W)
Idle + mobile data on 1 (9 V)
147
1.32
Idle + mobile data on 1 (12 V)
125
1.5
Idle + mobile data on 1 (24 V)
64
1.54


Test type
Current (mA)
Power consumption (W)
Mobile data on 1 + 1 LAN device connected 2 (9 V)
197
1.77
Mobile data on 1 + 1 LAN device connected 2 (12 V)
148
1.78
Mobile data on 1 + 1 LAN device connected 2 (24 V)
79
1.9


Test type
Current (mA)
Power consumption (W)
2 LAN devices connected 2 + high CPU load 3 + max speed LTE transmission + data transfer via WiFi (9 V)
423
3.81
2 LAN devices connected 2 + high CPU load 3 + max speed LTE transmission + data transfer via WiFi (12 V)
318
3.82
2 LAN devices connected 2 + high CPU load 3 + max speed LTE transmission + data transfer via WiFi (24 V)
169
4.06


1 - Only mobile data connection established with no additional traffic.
2 - Data streams between RUT360 and other connected LAN devices created using iPerf.
3 - Load created using md5sum (calculation and verification of 128-bit MD5 hashes).
Power consumption may differ due to mobile data transmission speed, testing environment and conditions.