'''Averaged''' TSW212 power consumption values in different states of operation are represented in the table(s) below:
<table class="nd-othertables_3">
<table class="nd-othertables_3">
     <tr style="font-weight:bold">
     <tr style="font-weight:bold">
Line 114: Line 116:
     </tr>
     </tr>
</table>
</table>


<small><sup><small>1</small></sup> - Data streams between devices were created using iPerf3.</small> <br>
<small><sup><small>1</small></sup> - Data streams between devices were created using iPerf3.</small> <br>
<small>Power consumption may differ due to testing environment and conditions.</small>
<small>Power consumption may differ due to testing environment and conditions.</small>
[[Category:TSW212 Manual]]

Latest revision as of 08:24, 12 November 2024

Main Page > TSW Switches > TSW212 > TSW212 Manual > TSW212 Power Consumption

Averaged TSW212 power consumption values in different states of operation are represented in the table(s) below:

Test type
Current (mA)
Power consumption (W)
Idle (9 V)
141
1.27
Idle (12 V)
109
1.31
Idle (24 V)
57
1.37
Idle (44 V)
33
1.45
Idle (50 V)
29
1.45
Idle (57 V)
26
1.48


Test type
Current (mA)
Power consumption (W)
2 LAN devices connected + heavy data traffic1 (9 V)
236
2.12
2 LAN devices connected + heavy data traffic1 (12 V)
179
2.15
2 LAN devices connected + heavy data traffic1 (24 V)
95
2.28
2 LAN devices connected + heavy data traffic1 (44 V)
54
2.38
2 LAN devices connected + heavy data traffic1 (50 V)
48
2.40
2 LAN devices connected + heavy data traffic1 (57 V)
43
2.45


Test type
Current (mA)
Power consumption (W)
2 SFP and 8 LAN devices connected + heavy data traffic1 (9 V)
506
4.55
2 SFP and 8 LAN devices connected + heavy data traffic1 (12 V)
379
4.55
2 SFP and 8 LAN devices connected + heavy data traffic1 (24 V)
195
4.68
2 SFP and 8 LAN devices connected + heavy data traffic1 (44 V)
111
4.88
2 SFP and 8 LAN devices connected + heavy data traffic1 (50 V)
99
4.95
2 SFP and 8 LAN devices connected + heavy data traffic1 (57 V)
88
5.02

1 - Data streams between devices were created using iPerf3.
Power consumption may differ due to testing environment and conditions.