TRB140 Product Change Notifications: Difference between revisions

From Teltonika Networks Wiki
No edit summary
 
(23 intermediate revisions by 4 users not shown)
Line 6: Line 6:


__TOC__
__TOC__
{{Template:Device_Housing_Sticker_Visual_Changes
<!------------------------DEVICE----------------------->
| name        = TRB140
| FullDate        = 2024.11.22
| month        = December
| year        = 2024
| day        = 1
}}
{{Template:EAN code changes
<!------------------------DEVICE----------------------->
| name        = TRB140
}}
{{Template:2023 12 18 PCN Housing
<!------------------------DEVICE----------------------->
| name        = TRB140
| type        = gateway
| year        = 2025
| month        = January
| Full_date    = 2024.09.18
| File_Full_date    = 2024_09_18
}}
{{Template:PCN_RutOS_7.7
<!------------------------DEVICE----------------------->
| name        = TRB140
}}
{{Template: 2023-10-16_TRB_Firmware_Requirement_Change
<!------------------------DEVICE----------------------->
| name        = TRB140
}}
{{Template:MAC Address Range Change PCN}}
==2022.11.25: Default password change==
All TRB140 devices manufactured starting from 2022, week 50, will have unique default password.
{| class="wikitable"
|+
! colspan="2" style="text-align: left; background: white;" |Change description
|-
| style="text-align: left; background: white;" |Change type
| style="text-align: left; background: white;" |Default password change.
|-
| style="width: 221px; text-align: left; background: white;" | Detailed description
| style="width: 908px; text-align: left; background: white;" | TRB140 devices manufactured starting from Q4 2022 will have unique default password.
|-
| style="text-align: left; background: white;" | Change reasons
| style="text-align: left; background: white;" | Increasing device security.
|-
|}
{| class="wikitable"
|+
! style="text-align: left; background: white;" colspan="3" | Affected products information
|-
| style="width: 221px; text-align: left; background: white;" | Model
| style="width: 448px; text-align: left; background: white;" | Affected order codes
| style="width: 448px; text-align: left; background: white;" | Order code changes
|-
| style="text-align: left; background: white;" | TRB140
| style="text-align: left; background: white;" | TRB140 ******
| style="text-align: left; background: white;" | No changes
|-
| style="text-align: left; background: white;" | Upcoming change date
| style="text-align: left; background: white;" colspan="2" | 2022, week 50
|-
|}
{| class="wikitable"
|+
! colspan="3" style="text-align: left; background: white;" |Change impact
|-
| style="width: 221px; text-align: left; background: white;" |Risk assessment
| colspan="2" style="width: 908px; text-align: left; background: white;" |Device install procedures or any automated solutions might need modifications. '''Please note:''' this product change notification does not affect any previous TRB140 devices.
|-
| style="text-align: left; background: white;" |Suggested implementation plan
| colspan="2" style="text-align: left; background: white;" |
For more detailed information please contact your sales representative.
|-
|}
{| class="wikitable"
|+
! style="width: 1141px; text-align: left; background: white;" colspan="3" | Acknowledgement of PCN receipt
|-
| style="text-align: left; background: white;" colspan="3"| If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above.
|-
|}
To download the pdf version of this notification, [[Media:PCN_TRB140_2022_11_25_EN_DPC.pdf|click here]].
==2022.11.25: QSG flyer replacement==
Starting from 2022, week 50, TRB140 gateway will come with a new QSG flyer in the packaging.
{| class="wikitable"
|+
! style="text-align: left; background: white;" colspan="3" | Change description
|-
| style="text-align: left; background: white;" | Change type
| style="text-align: left; background: white;" colspan="2" | Replacement of QSG flyer
|-
| style="width: 221px; text-align: left; background: white;" rowspan="3" | Detailed description
| style="width: 908px; text-align: left; background: white;" colspan="2" | TRB140 devices manufactured starting from Q4 2022 will have a new QSG flyer in the packaging. The new QSG flyer includes the short version of QSG with a QR code/link to the full Web QSG version: [https://teltonika-networks.com/QSG_TRB140 teltonika-networks.com/QSG_TRB140]
|-
| style="text-align: left; background: white;" | Previous design:<br> [[File:QSG TRB140 EN old.png|center|300px]]
| style="text-align: left; background: white;" | New design: <br> [[File:QSG TRB140 EN new.png|center|300px]]
|-
| style="text-align: left; background: white;" colspan="2" | The new flyer will include QR codes with URL links to RMS and the Web version of the QSG (Quick Start Guide) for the TRB140.
|-
| style="text-align: left; background: white;" | Change reasons
| style="text-align: left; background: white;" colspan="2" | Reducing environmental impact.
|-
|}
{| class="wikitable"
|+
! style="text-align: left; background: white;" colspan="3" | Affected products information
|-
| style="width: 221px; text-align: left; background: white;" | Model
| style="width: 448px; text-align: left; background: white;" | Affected order codes
| style="width: 448px; text-align: left; background: white;" | Order code changes
|-
| style="text-align: left; background: white;" | TRB140
| style="text-align: left; background: white;" | TRB140 ******
| style="text-align: left; background: white;" | No changes
|-
| style="text-align: left; background: white;" | Upcoming change date
| style="text-align: left; background: white;" colspan="2" | 2022, week 50
|-
|}
{| class="wikitable"
|+
! style="text-align: left; background: white;" colspan="3" | Change impact
|-
| style="width: 221px; text-align: left; background: white;" | Risk assessment
| style="width: 908px; text-align: left; background: white;" colspan="2"| Marketing material such as photos might need replacing.
|-
| style="text-align: left; background: white;" | Suggested implementation plan
| style="text-align: left; background: white;" colspan="2"| Information included in this PCN will help adapt to the upcoming changes.
|-
|}
{| class="wikitable"
|+
! style="width: 1141px; text-align: left; background: white;" colspan="3" | Acknowledgement of PCN receipt
|-
| style="text-align: left; background: white;" colspan="3"| If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above
|-
|}
To download the pdf version of this notification, [[Media:PCN TRB140 2022 11 25 EN QFR.pdf|click here]].
==2022.11.25: Changes in engraving/labeling==
Starting from 2022, week 50, TRB140 gateways will be produced with modified bottom engraving/labeling.
{| class="wikitable"
|+
! colspan="4" style="text-align: left; background: white;" |Change description
|-
| style="text-align: left; background: white;" |Change type
| colspan="3" style="text-align: left; background: white;" |External/visual
|-
| rowspan="2" style="width: 221px; text-align: left; background: white;" |Detailed description
| colspan="2" style="width: 908px; text-align: left; background: white;" |The device's unique default password will be added to the bottom engraving/labeling. The formatting for the remaining information on the labeling/engraving will be adjusted, and the Fira font will be used instead of Arial. The device's unique default password information will also be added to the QR code Information displayed after scanning QR code with syntax: SN:<nowiki>{{SN}}</nowiki>;I:<nowiki>{{IMEI}}</nowiki>;M:<nowiki>{{MAC}}</nowiki>;U:admin;PW:<nowiki>{{DEVICEPASSWORD}}</nowiki>;B:<nowiki>{{BATCH}}</nowiki>;
From the device top engraving/labeling, the previously relevant authentication information text will be removed: '''User/Pass: admin/admin01'''.
The labeling on the product packaging will stay unchanged.
|- style="width: 40%; text-align: left; background: white;"
|'''Old top engraving/labeling:''' <br> [[File:Trb140_hd_1.png|center|300px]]
'''Old bottom engraving/labeling:''' <br>
[[File:600px-Networking TRB140 first start gaminio lipdukas v3.png|center|300px]]
|'''New top engraving/labeling:''' <br> [[File:TRB140_hd_4_new_top.png|center|300px]]
'''New bottom engraving/labeling:''' <br>
[[File:RUT informacinis lipdukas ant gaminio 62x26mm v1.xml7.png|center|300px]]
|-
| style="text-align: left; background: white;" |Change reasons
| colspan="2" style="text-align: left; background: white;" |To accommodate the change from the standard default password to a unique default password for each device.
|-
|}
{| class="wikitable"
|+
! style="text-align: left; background: white;" colspan="3" | Affected products information
|-
| style="width: 221px; text-align: left; background: white;" | Model
| style="width: 448px; text-align: left; background: white;" | Affected order codes
| style="width: 448px; text-align: left; background: white;" | Order code changes
|-
| style="text-align: left; background: white;" | TRB140
| style="text-align: left; background: white;" | TRB140 ******
| style="text-align: left; background: white;" | No changes
|-
| style="text-align: left; background: white;" | Upcoming change date
| style="text-align: left; background: white;" colspan="2" | 2022, week 50
|-
|}
{| class="wikitable"
|+
! colspan="3" style="text-align: left; background: white;" |Change impact
|-
| style="width: 221px; text-align: left; background: white;" |Risk assessment
| colspan="2" style="width: 908px; text-align: left; background: white;" |Changes to top labeling/engraving. Device's unique default password will be present on the product itself. This might impact marketing materials due to changing contents of the bottom informational engraving/labeling.
|-
| style="text-align: left; background: white;" |Suggested implementation plan
| colspan="2" style="text-align: left; background: white;" |No implementation plan needed.
|-
|}
{| class="wikitable"
|+
! colspan="3" style="width: 1141px; text-align: left; background: white;" |Acknowledgement of PCN receipt
|-
| colspan="3" style="text-align: left; background: white;" |If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above.
|-
|}
To download the pdf version of this notification, [[Media:PCN_TRB140_2022_11_25_EN_CIEL.pdf|click here]].
==2022-05-24: Ethernet Transceiver chip change==
All TRB140 devices manufactured from Q3 2022, will require firmware version '''TRB1_R_00.07.02''' or newer for the Ethernet interface to utilize Ethernet functionality properly.
{| class="wikitable"
|+
! colspan="3" style="text-align: left; background: white;" |Change description
|-
| style="text-align: left; background: white;" |Change type
| colspan="2" style="text-align: left; background: white;" |Ethernet Transceiver chip changed.
|-
| rowspan="3" style="width: 221px; text-align: left; background: white;" |Detailed description
| colspan="2" style="width: 908px; text-align: left; background: white;" |All TRB140 devices manufactured from Q3 2022, will require firmware version '''TRB1_R_00.07.02''' or newer for the Ethernet interface to utilize Ethernet functionality properly.<br>
Ethernet functionality will not be supported with previous firmware versions.
Custom firmware built on previous SDK versions will not support Ethernet functionality for devices manufactured starting from Q3 2022.
|-
| style="text-align: left; background: white;" |Change reasons
| colspan="2" style="text-align: left; background: white;" |Reducing product lead times.
|-
|}
{| class="wikitable"
|+
! colspan="2" style="width: 1154px; text-align: left; background: white;" |Affected products information
|-
| colspan="2" style="text-align: left; background: white;" |All TRB140 ****** product codes are affected. No product code changes.
|-
| style="text-align: left; background: white;" |Product release date
| style="text-align: left; background: white;" |Q3 2022
|-
|}
{| class="wikitable"
|+
! colspan="3" style="text-align: left; background: white;" |Change impact
|-
| style="width: 221px; text-align: left; background: white;" |Risk assessment
| colspan="2" style="width: 908px; text-align: left; background: white;" |It is advised to test '''TRB1_R_00.07.02''' Firmware release.
|-
| style="text-align: left; background: white;" |Suggested implementation plan
| colspan="2" style="text-align: left; background: white;" |
Firmware downloads for the device can be found [https://wiki.teltonika-networks.com/view/TRB140_Firmware_Downloads here].
For more detailed information please contact your sales representative.
|-
|}
{| class="wikitable"
|+
! colspan="3" style="width: 1141px; text-align: left; background: white;" |Acknowledgement of PCN receipt
|-
| colspan="3" style="text-align: left; background: white;" |If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above
|-
|}
To download the pdf version of this notification, [[Media:PCN TRB140 2022-05-24 EN.pdf|click here]].
==2020.08.14: changes in bottom labeling==
Effective 2020, week 36, TRB140 gateways will be produced with modified bottom labeling/engraving.
{| class="wikitable"
|+
! colspan="4" style="text-align: left; background: white;" |Change description
|-
| style="text-align: left; background: white;" |Change type
| colspan="3" style="text-align: left; background: white;" |External/visual
|-
| rowspan="2" style="width: 221px; text-align: left; background: white;" |Detailed description
| colspan="2" style="width: 908px; text-align: left; background: white;" |The product code will be removed from the bottom labeling/engraving. The formatting for the remaining information on the labeling/engraving will be adjusted. Product code information will also be removed from the QR code.
The labeling on the product packaging will stay unchanged.
|- style="width: 40%; text-align: left; background: white;"
|Old version: <br> [[File:Networking_trb140_first_start_gaminio_lipdukas_v2.png|center|300px]]
|New version: <br> [[File:TRB140 TRB2x5 informacinis lipdukas ant gaminio 58x25mm v3.png|center|300px]]
|-
| style="text-align: left; background: white;" |Change reasons
| colspan="2" style="text-align: left; background: white;" |Placing product code on the product itself is misleading, product code describes what is included in the product equipment package, not in the product itself.
|-
|}
{| class="wikitable"
|+
! colspan="2" style="width: 1154px; text-align: left; background: white;" |Affected products information
|-
| colspan="2" style="text-align: left; background: white;" |All TRB14* ****** product codes are affected. No product code changes.
|-
| style="text-align: left; background: white;" |Product release date
| style="text-align: left; background: white;" |2020, week 36
|-
|}
{| class="wikitable"
|+
! colspan="3" style="text-align: left; background: white;" |Change impact
|-
| style="width: 221px; text-align: left; background: white;" |Risk assessment
| colspan="2" style="width: 908px; text-align: left; background: white;" |The exact product code will not be present on the product itself, the exact product code will be found on the packaging box or determined by serial number. This might impact marketing materials due to changing contents of the bottom informational laser engraving.
|-
| style="text-align: left; background: white;" |Suggested implementation plan
| colspan="2" style="text-align: left; background: white;" |No implementation plan needed
|-
|}
{| class="wikitable"
|+
! colspan="3" style="width: 1141px; text-align: left; background: white;" |Acknowledgement of PCN receipt
|-
| colspan="3" style="text-align: left; background: white;" |If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above
|-
|}
To download the pdf version of this notification, [[Media:PCN TRB140 20200814 EN.pdf|click here]].


==2020.06.12: RUTOS support==
==2020.06.12: RUTOS support==
Line 47: Line 403:
|-
|-
| style="text-align: left; background: white;" |Suggested implementation plan
| style="text-align: left; background: white;" |Suggested implementation plan
| colspan="2" style="text-align: left; background: white;" |Special preparations are unneeded.
| colspan="2" style="text-align: left; background: white;" |Special preparations are unneeded
|-
|-
|}
|}
Line 75: Line 431:
| colspan="3" style="width: 908px; text-align: left; background: white;" |Power supply unit changed
| colspan="3" style="width: 908px; text-align: left; background: white;" |Power supply unit changed
|-
|-
| colspan="2" style="text-align: left; background: white; vertical-align: text-top;" |Before: <br> [[File:Trb140_hd_1.png|left|350px]]
| colspan="2" style="text-align: left; background: white; vertical-align: text-top;" |Before: <br><br><br> [[File:Trb140_old.png|left|300px]]
| style="text-align: left; background: white; vertical-align: text-top;" |After: <br> [[File:Trb140_hd_5_demo.jpg|left|300px]]
| style="text-align: left; background: white; vertical-align: text-top;" |After: <br> [[File:Trb140_hd_1.png|left|300px]]
|-
|-
| style="text-align: left; background: white;" |Change reasons
| style="text-align: left; background: white;" |Change reasons
Line 194: Line 550:


To download the pdf version of this notification, [[Media:PCN TRB14x 20190520 EN.pdf|click here]].
To download the pdf version of this notification, [[Media:PCN TRB14x 20190520 EN.pdf|click here]].
[[Category:TRB140]]

Latest revision as of 11:25, 22 November 2024

Main Page > TRB Gateways > TRB140 > TRB140 Product Change Notifications

Product change notifications (PCN) is a way of informing customers of upcoming changes related to Teltonika Networks products. This includes outward appearance adjustments, hardware improvements, changes to package contents, etc. Changes related to a product's firmware are not included in PCNs (click here to see the firmware changelog).

This page stores information regarding changes to the TRB140 device. Below you will find a list of both upcoming and already implemented changes sorted by newest to oldest (top to bottom).

2024.11.22: Device Housing - Engraving/Labeling changes

Starting from December 2024, TRB140 devices will be produced with top and bottoms stickers.

PCN Number: PCN_Housing_Engraving.Labeling_TRB140_2024.11.22_EN
Change description
Change type Visual Changes
Detailed description The device will be manufactured with top and bottom stickers instead of engravings due to the thickness of the paint coating on the housing. The information on the stickers will not be affected.

Please note that this change will be implemented gradually, throughout a 1-month transitional period starting from December, 2024. During this period, your shipments of TRB140 may consist of either the current design or the new one described above.

Change reasons Reducing the risk for client to receive lower quality engraving on the housing.
Affected products information
Model Affected order codes Order code changes
TRB140 TRB140 ***** No changes
Upcoming change date December 1st, 2024
Change impact
Risk assessment

No risk factors are associated with this change. Please note: this product change notification does not affect any previous TRB140 devices, except new TRB140 devices that will be manufactured with this change.

Suggested implementation plan

Information included in this PCN will help adapt to the upcoming changes. For more detailed information, please contact your sales representative.

Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above.

To download the pdf version of this notification, click here.

2024.09.18: EAN Code Change

Starting from October 1st 2024, new order codes created will have their own unique EAN codes.

PCN Number: PCN_EAN_Code_Change_TRB140_2024.09.18_EN
Change description
Change type Logistics change
Detailed description The product identification system is being updated by assigning unique EAN codes to each new order code created from October 1st.
Change reasons Improving product traceability, inventory management, and logistics accuracy across ordering and distribution systems.
Affected products information
Model Affected order codes Order code changes
TRB140 TRB140 ***** No changes
Upcoming change date October 1st, 2024
Change impact
Risk assessment

Every order code, created after this change, will have its own unique EAN code. Therefore, it might cause the need to review inventory management and ordering processes.

Suggested implementation plan

Information included in this PCN will help adapt to the upcoming changes. For more detailed information, please contact your sales representative.

Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above.

To download the pdf version of this notification, click here.

2024.09.18: Visual colour housing changes

Beginning in January 2025, TRB140 gateway will be manufactured with a different colour housing.

PCN Number: PCN_TRB140_2024_09_18_EN
Change description
Change type Housing colour
Detailed description TRB140 devices will be produced with a new black housing.


Please note that this change will be implemented gradually, throughout a 3-month transitional period starting in January 2025. During this period, your shipments of TRB140 may consist of either the current design or the new one described above.

Current design:

New design:

The housing dimensions will not be changed.
Change reasons Design improvement.
Affected products information
Model Affected order codes Order code changes
TRB140 TRB140 ****** N/A
Upcoming change date 2025 January
Change impact
Risk assessment Marketing material such as photos might need replacing.
Suggested implementation plan Marketing material regarding the changes will be found at our wiki: https://wiki.teltonika-networks.com/view/TRB140_Marketing_Material
For more detailed information please contact your sales representative.
Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above

To download the pdf version of this notification, click here.

2024.03.08: Reset button functionality change RutOS 7.07

With the release of RutOS version 7.07, TRB140 device will experience changes related to the security improvements of the device.

PCN Number: PCN_RUTOS_CHANGE_2024_03_08_EN
Change description
Change type Firmware change
Detailed description Previously, during device resets, logs, RMS connection state data, and SIM PIN settings remained unchanged. However, starting with RutOS firmware version 7.07, all devices will uniformly reset logs, RMS connection state data, and SIM PIN settings to factory defaults when using the reset button. Other reset methods, including WebUI, SMS, and others, will remain unimpacted by this change.
Change reasons Increasing security
Affected products information
Model Affected order codes Order code changes
TRB140 TRB140 ****** No changes
Upcoming change date 2024 Q2, with the release of RutOS 7.07
Change impact
Risk assessment
  • The loss of device logs upon utilizing the reset button may disrupt operational records and slow down subsequent troubleshooting efforts.
  • Failure to set up the SIM PIN post-reset via the reset button may result in SIM card lockout due to repeated incorrect PIN entries, causing service disruption and requiring either SIM replacement or PIN reset.
  • The device is still visible in RMS post-reset but cannot be accessed. Therefore, re-adding the device to RMS is necessary for continued access.
Suggested implementation plan

Information included in this PCN will help adapt to the upcoming changes. For more detailed information, please contact your sales representative.

Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above.

To download the pdf version of this notification, click here.

2023.10.16: Firmware Requirement Change

Starting from November 2023, all TRB140 devices will be manufactured with a new firmware version. They will require firmware version TRB1_R_00.07.05 or newer.

Change description
Change type Firmware Requirement Change
Detailed description Starting November 2023, all TRB140 devices will be manufactured with a new firmware version. They will require firmware version TRB1_R_00.07.05 or newer. Downgrading to previous firmware versions will no longer be supported.

Please note that this change will be implemented gradually, throughout a 4-month transitional period starting from November 2023. During this period, your shipments of TRB140 may consist of either the previous version or the new one described above.

Change reasons Support for newest Quectel modem firmware
Affected products information
All TRB140 ****** product codes are affected. No product code changes.
Product release date November 2023
Change impact
Risk assessment No risk factors are asociated with this change.

Please note: this product change notification does not affect any previous TRB140 devices, except new TRB140 devices.

Suggested implementation plan

For more detailed information please contact your sales representative.

Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above

To download the pdf version of this notification, click here.

2023.02.13: MAC address range change

All Teltonika Networks devices manufactured starting from 2023, week 9 will have additional new MAC address range.

Change description
Change type MAC address range
Detailed description All Teltonika Networks devices manufactured starting from 2023, week 9 may have a MAC address from the new MAC address range 20:97:27:00:00:00 - 20:97:27:FF:FF:FF, as well as the current MAC address range 00:1E:42:00:00:00 - 00:1E:42:FF:FF:FF
Change reasons Endpoint of the previous MAC address range.
Affected products information
Model Affected order codes Order code changes
All Teltonika Networks devices All order codes No changes
Upcoming change date 2023, week 9
Change impact
Risk assessment Device install procedures or any automated solutions might need modifications.
Suggested implementation plan

For more detailed information please contact your sales representative.

Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above.

To download the pdf version of this notification, click here.

2022.11.25: Default password change

All TRB140 devices manufactured starting from 2022, week 50, will have unique default password.

Change description
Change type Default password change.
Detailed description TRB140 devices manufactured starting from Q4 2022 will have unique default password.
Change reasons Increasing device security.
Affected products information
Model Affected order codes Order code changes
TRB140 TRB140 ****** No changes
Upcoming change date 2022, week 50
Change impact
Risk assessment Device install procedures or any automated solutions might need modifications. Please note: this product change notification does not affect any previous TRB140 devices.
Suggested implementation plan

For more detailed information please contact your sales representative.

Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above.

To download the pdf version of this notification, click here.

2022.11.25: QSG flyer replacement

Starting from 2022, week 50, TRB140 gateway will come with a new QSG flyer in the packaging.

Change description
Change type Replacement of QSG flyer
Detailed description TRB140 devices manufactured starting from Q4 2022 will have a new QSG flyer in the packaging. The new QSG flyer includes the short version of QSG with a QR code/link to the full Web QSG version: teltonika-networks.com/QSG_TRB140
Previous design:
New design:
The new flyer will include QR codes with URL links to RMS and the Web version of the QSG (Quick Start Guide) for the TRB140.
Change reasons Reducing environmental impact.
Affected products information
Model Affected order codes Order code changes
TRB140 TRB140 ****** No changes
Upcoming change date 2022, week 50
Change impact
Risk assessment Marketing material such as photos might need replacing.
Suggested implementation plan Information included in this PCN will help adapt to the upcoming changes.
Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above

To download the pdf version of this notification, click here.

2022.11.25: Changes in engraving/labeling

Starting from 2022, week 50, TRB140 gateways will be produced with modified bottom engraving/labeling.

Change description
Change type External/visual
Detailed description The device's unique default password will be added to the bottom engraving/labeling. The formatting for the remaining information on the labeling/engraving will be adjusted, and the Fira font will be used instead of Arial. The device's unique default password information will also be added to the QR code Information displayed after scanning QR code with syntax: SN:{{SN}};I:{{IMEI}};M:{{MAC}};U:admin;PW:{{DEVICEPASSWORD}};B:{{BATCH}};


From the device top engraving/labeling, the previously relevant authentication information text will be removed: User/Pass: admin/admin01.


The labeling on the product packaging will stay unchanged.

Old top engraving/labeling:

Old bottom engraving/labeling:

New top engraving/labeling:

New bottom engraving/labeling:

Change reasons To accommodate the change from the standard default password to a unique default password for each device.
Affected products information
Model Affected order codes Order code changes
TRB140 TRB140 ****** No changes
Upcoming change date 2022, week 50
Change impact
Risk assessment Changes to top labeling/engraving. Device's unique default password will be present on the product itself. This might impact marketing materials due to changing contents of the bottom informational engraving/labeling.
Suggested implementation plan No implementation plan needed.
Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above.

To download the pdf version of this notification, click here.


2022-05-24: Ethernet Transceiver chip change

All TRB140 devices manufactured from Q3 2022, will require firmware version TRB1_R_00.07.02 or newer for the Ethernet interface to utilize Ethernet functionality properly.

Change description
Change type Ethernet Transceiver chip changed.
Detailed description All TRB140 devices manufactured from Q3 2022, will require firmware version TRB1_R_00.07.02 or newer for the Ethernet interface to utilize Ethernet functionality properly.

Ethernet functionality will not be supported with previous firmware versions.


Custom firmware built on previous SDK versions will not support Ethernet functionality for devices manufactured starting from Q3 2022.

Change reasons Reducing product lead times.
Affected products information
All TRB140 ****** product codes are affected. No product code changes.
Product release date Q3 2022
Change impact
Risk assessment It is advised to test TRB1_R_00.07.02 Firmware release.
Suggested implementation plan

Firmware downloads for the device can be found here.

For more detailed information please contact your sales representative.

Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above

To download the pdf version of this notification, click here.


2020.08.14: changes in bottom labeling

Effective 2020, week 36, TRB140 gateways will be produced with modified bottom labeling/engraving.

Change description
Change type External/visual
Detailed description The product code will be removed from the bottom labeling/engraving. The formatting for the remaining information on the labeling/engraving will be adjusted. Product code information will also be removed from the QR code.

The labeling on the product packaging will stay unchanged.

Old version:
New version:
Change reasons Placing product code on the product itself is misleading, product code describes what is included in the product equipment package, not in the product itself.
Affected products information
All TRB14* ****** product codes are affected. No product code changes.
Product release date 2020, week 36
Change impact
Risk assessment The exact product code will not be present on the product itself, the exact product code will be found on the packaging box or determined by serial number. This might impact marketing materials due to changing contents of the bottom informational laser engraving.
Suggested implementation plan No implementation plan needed
Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above

To download the pdf version of this notification, click here.

2020.06.12: RUTOS support

Effective since June 03, 2020, TRB140 support RutOS v2.3, available at TRB140 Firmware downloads.

Change description
Change type Firmware
Detailed description Added RutOS Support for TRB14x series gateways
Change reasons Until now different TRB series gateways had their own FW version depening on LTE module. After this update FW will become common to all TRB14x gateways.
Affected products information
Model Affected order codes Order code changes
TRB140 TRB140 ****** No changes
Change impact
Risk assessment Migration from TRB1400_R_00.01.06.1 or older requires Legacy firmware
RutOS v2.3 includes Basic and Advanced modes, so some functionality may appear missing until Advanced mode is selected
Suggested implementation plan Special preparations are unneeded
Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above.

To download the pdf version of this notification, click here.

2019.05.30: New housing

Effective July, 2019, TRB140 devices will be produced with new rugged housing.

Change description
Change type Rugged housing standard order code added
Detailed description Power supply unit changed
Before:


After:
Change reasons Improved ruggedness.
Affected products information
Standard order code will include housing
Device New standard code Optional order code (without housing)
TRB140 TRB140003000 TRB140000000
Product release date July, 2019
Change impact
Risk assessment Pricing and lead time may be subject to change.
Marketing material such as photos or specification changes.
Suggested implementation plan Updated marketing material can be found here. For more detailed, information please contact your sales representative.
Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above.

To download the pdf version of this notification, click here.

2019.05.20: Power supply unit (PSU) changed

Effective June, 2019, TRB140 devices will be sold with new power supply units (PSU).

Change description
Change type Power supply
Detailed description Power supply unit changed
Current PSUs:
New PSUs:
PSU specifications
Electrical 9 VDC, 1 A (9 W) 9 VDC, 0.5 A (4.5 W)
Dimensions EU: 26 x 74 x 43 mm
UK: 48 x 73 x 47 mm
US: 26 x 74 x 43 mm
AU: 40 x 74 x 51 mm
EU: 26 x 59 x 41 mm
UK: 50 x 62 x 49 mm
US: 26 x 59 x 41 mm
AU: 41 x 59 x 49 mm
Change reasons Power supply optimized for TRB14x series devices.
Affected products information
Model Affected order codes Order code changes
TRB14* TRB14* ****** No changes
Product release date June, 2019
Change impact
Risk assessment Marketing material such as photos or specification changes.
Suggested implementation plan Marketing material can be found here.
PSU datasheets can be found here
Information included in this PCN will help adapt to the upcoming changes.
Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above.

To download the pdf version of this notification, click here.