Line 25: Line 25:
====Connector pinout====
====Connector pinout====
----
----
The RS232 connector type on this device is a '''DCE female'''. DCE stands for Data Communication Equipment.  
The following table lists commonly used RS-232 signals ('''DTE male''' to '''DCE female'''). The RS232 connector type on device is a DCE female.


[[File:Services_rs232_connector.PNG|400px]]
[[File:Services_rs232_connector_v1.png|400px]]


<table class="nd-othertables">
<table class="nd-othertables">
Line 40: Line 40:
       <td>DCD</td>
       <td>DCD</td>
       <td>Data Carrier Detect</td>
       <td>Data Carrier Detect</td>
       <td>Output</td>
       <td>Input</td>
     </tr>
     </tr>
     <tr>
     <tr>
Line 46: Line 46:
       <td>RXD</td>
       <td>RXD</td>
       <td>Receive Data</td>
       <td>Receive Data</td>
       <td>Output</td>
       <td>Input</td>
     </tr>
     </tr>
     <tr>
     <tr>
Line 52: Line 52:
         <td>TXD</td>
         <td>TXD</td>
         <td>Transmit Data</td>
         <td>Transmit Data</td>
       <td>Input</td>
       <td>Output</td>
     </tr>
     </tr>
     <tr>
     <tr>
Line 58: Line 58:
         <td>DTR</td>
         <td>DTR</td>
         <td>Data Terminal Ready</td>
         <td>Data Terminal Ready</td>
       <td>Input</td>
       <td>Output</td>
     </tr>
     </tr>
     <tr>
     <tr>
Line 70: Line 70:
       <td>DSR</td>
       <td>DSR</td>
       <td>Data Set Ready</td>
       <td>Data Set Ready</td>
       <td>Output</td>
       <td>Input</td>
     </tr>
     </tr>
     <tr>
     <tr>
Line 76: Line 76:
         <td>RTS</td>
         <td>RTS</td>
         <td>Ready To Send</td>
         <td>Ready To Send</td>
       <td>Input</td>
       <td>Output</td>
     </tr>
     </tr>
     <tr>
     <tr>
Line 82: Line 82:
         <td>CTS</td>
         <td>CTS</td>
         <td>Clear To Send</td>
         <td>Clear To Send</td>
       <td>Output</td>
       <td>Input</td>
     </tr>{{#ifeq:{{{series}}}|TRB1|
     </tr>{{#ifeq:{{{series}}}|TRB1|
     <tr>
     <tr>
Line 88: Line 88:
         <td>RI</td>
         <td>RI</td>
         <td>Ring Indicator</td>
         <td>Ring Indicator</td>
       <td>Output (connected to +3.8V permanently via a 4.7k resistor) </td>
       <td>Input (connected to +3.8V permanently via a 4.7k resistor) </td>
     </tr>|
     </tr>|
     <tr>
     <tr>
Line 94: Line 94:
         <td>RI</td>
         <td>RI</td>
         <td>Ring Indicator</td>
         <td>Ring Indicator</td>
       <td>Output (connected to +5V permanently via a 4.7k resistor) </td>
       <td>Input (connected to +5V permanently via a 4.7k resistor) </td>
     </tr>}}
     </tr>}}
</table>
</table>
Line 335: Line 335:


===Advanced settings===
===Advanced settings===
 
{{#switch: {{{name}}} | TRB142 | TRB145 =
[[File:Networking_rutos_manual_serial_utilities_modem_control_advanced_settings.png|border|class=tlt-border]]
[[File:Networking_rutos_manual_serial_utilities_modem_control_advanced_settings_trb.png|border|class=tlt-border]]
| #default = [[File:Networking_rutos_manual_serial_utilities_modem_control_advanced_settings.png|border|class=tlt-border]]}}


<table class="nd-mantable">
<table class="nd-mantable">
Line 348: Line 349:
       <td>string; default: <b>none</b></td>
       <td>string; default: <b>none</b></td>
       <td>Prints message to serial device when modem control is ready.</td>
       <td>Prints message to serial device when modem control is ready.</td>
     </tr>
     </tr>{{#switch: {{{name}}} | TRB142 | TRB145 =
    <tr>
      <td>Data mode</td>
      <td>off {{!}} on; default: <b>off</b></td>
      <td>Enable this option to allow data mode. Data mode will not operate without it.</td>
    </tr>| #default =}}
     <tr>
     <tr>
       <td>Canonical mode</td>
       <td>Canonical mode</td>