RUT140 power consumption values in different states of operation are represented in the table(s) below:<br><br>
'''Averaged''' RUT140 power consumption values in different states of operation are represented in the table(s) below:<br>
<table class="nd-othertables_3">
<table class="nd-othertables_3">
     <tr style="font-weight:bold">
     <tr style="font-weight:bold">
Line 8: Line 8:
     <tr>
     <tr>
         <td>Idle (9 V)</td>
         <td>Idle (9 V)</td>
       <td><center><b>88</b></center></td>
       <td><center><b>78</b></center></td>
       <td><center><b>0.79</b></center></td>
       <td><center><b>0.7</b></center></td>
     </tr>
     </tr>
     <tr>
     <tr>
         <td>Idle (12 V)</td>
         <td>Idle (12 V)</td>
       <td><center><b>67</b></center></td>
       <td><center><b>60.5</b></center></td>
       <td><center><b>0.80</b></center></td>
       <td><center><b>0.73</b></center></td>
     </tr>
     </tr>
     <tr>
     <tr>
         <td>Idle (24 V)</td>
         <td>Idle (24 V)</td>
       <td><center><b>40</b></center></td>
       <td><center><b>33.4</b></center></td>
       <td><center><b>0.96</b></center></td>
       <td><center><b>0.8</b></center></td>
     </tr>
     </tr>
</table>
</table>
Line 32: Line 32:
     <tr>
     <tr>
         <td>1 LAN devices connected <sup><small>1</small></sup> (9 V)</td>
         <td>1 LAN devices connected <sup><small>1</small></sup> (9 V)</td>
       <td><center><b>113</b></center></td>
       <td><center><b>120.6</b></center></td>
       <td><center><b>1.02</b></center></td>
       <td><center><b>1.08</b></center></td>
     </tr>
     </tr>
     <tr>
     <tr>
         <td>1 LAN devices connected <sup><small>1</small></sup> (12 V)</td>
         <td>1 LAN devices connected <sup><small>1</small></sup> (12 V)</td>
       <td><center><b>87</b></center></td>
       <td><center><b>91.6</b></center></td>
       <td><center><b>1.04</b></center></td>
       <td><center><b>1.1</b></center></td>
     </tr>
     </tr>
     <tr>
     <tr>
         <td>1 LAN devices connected <sup><small>1</small></sup> (24 V)</td>
         <td>1 LAN devices connected <sup><small>1</small></sup> (24 V)</td>
       <td><center><b>49</b></center></td>
       <td><center><b>50</b></center></td>
       <td><center><b>1.18</b></center></td>
       <td><center><b>1.2</b></center></td>
     </tr>
     </tr>
</table>
</table>
Line 56: Line 56:
     <tr>
     <tr>
         <td>2 LAN devices connected <sup><small>1</small></sup> + high CPU load <sup><small>2</small></sup> + data transfer via WiFi (9 V)</td>
         <td>2 LAN devices connected <sup><small>1</small></sup> + high CPU load <sup><small>2</small></sup> + data transfer via WiFi (9 V)</td>
       <td><center><b>133</b></center></td>
       <td><center><b>129.5</b></center></td>
       <td><center><b>1.2</b></center></td>
       <td><center><b>1.17</b></center></td>
     </tr>
     </tr>
     <tr>
     <tr>
         <td>2 LAN devices connected <sup><small>1</small></sup> + high CPU load <sup><small>2</small></sup> + data transfer via WiFi (12 V)</td>
         <td>2 LAN devices connected <sup><small>1</small></sup> + high CPU load <sup><small>2</small></sup> + data transfer via WiFi (12 V)</td>
       <td><center><b>103</b></center></td>
       <td><center><b>98.3</b></center></td>
       <td><center><b>1.27</b></center></td>
       <td><center><b>1.18</b></center></td>
     </tr>
     </tr>
     <tr>
     <tr>
         <td>2 LAN devices connected <sup><small>1</small></sup> + high CPU load <sup><small>2</small></sup> + data transfer via WiFi (24 V)</td>
         <td>2 LAN devices connected <sup><small>1</small></sup> + high CPU load <sup><small>2</small></sup> + data transfer via WiFi (24 V)</td>
       <td><center><b>58</b></center></td>
       <td><center><b>53.6</b></center></td>
       <td><center><b>1.39</b></center></td>
       <td><center><b>1.29</b></center></td>
     </tr>
     </tr>
</table>
</table>
Line 75: Line 75:
<small><sup><small>2</small></sup> - Load created using ''md5sum'' (calculation and verification of 128-bit MD5 hashes). </small> <br>
<small><sup><small>2</small></sup> - Load created using ''md5sum'' (calculation and verification of 128-bit MD5 hashes). </small> <br>
<small>Power consumption may differ due to mobile data transmission speed, testing environment and conditions.</small>
<small>Power consumption may differ due to mobile data transmission speed, testing environment and conditions.</small>
[[Category:RUT140 Manual]]

Latest revision as of 08:12, 17 July 2025

Main Page > RUT Routers > RUT140 > RUT140 Manual > RUT140 Power Consumption

Averaged RUT140 power consumption values in different states of operation are represented in the table(s) below:

Test type
Current (mA)
Power consumption (W)
Idle (9 V)
78
0.7
Idle (12 V)
60.5
0.73
Idle (24 V)
33.4
0.8


Test type
Current (mA)
Power consumption (W)
1 LAN devices connected 1 (9 V)
120.6
1.08
1 LAN devices connected 1 (12 V)
91.6
1.1
1 LAN devices connected 1 (24 V)
50
1.2


Test type
Current (mA)
Power consumption (W)
2 LAN devices connected 1 + high CPU load 2 + data transfer via WiFi (9 V)
129.5
1.17
2 LAN devices connected 1 + high CPU load 2 + data transfer via WiFi (12 V)
98.3
1.18
2 LAN devices connected 1 + high CPU load 2 + data transfer via WiFi (24 V)
53.6
1.29


1 - Data streams between RUT140 and other connected LAN devices created using iPerf.
2 - Load created using md5sum (calculation and verification of 128-bit MD5 hashes).
Power consumption may differ due to mobile data transmission speed, testing environment and conditions.