Line 136: |
Line 136: |
| <table class="nd-mantable"> | | <table class="nd-mantable"> |
| <tr> | | <tr> |
− | <th>Field name</th> | + | <th>Field</th> |
| <th>Value</th> | | <th>Value</th> |
| <th>Description</th> | | <th>Description</th> |
Line 142: |
Line 142: |
| <tr> | | <tr> |
| <td>Name</td> | | <td>Name</td> |
− | <td>string; Default: <b>Unnamed Parameter</b></td> | + | <td>string; default: <b>Unnamed Parameter</b></td> |
− | <td>Request name. Used for easier management purposes</td> | + | <td>Request name. Used for easier management purposes.</td> |
| </tr> | | </tr> |
| <tr> | | <tr> |
| <td>Data type</td> | | <td>Data type</td> |
− | <td>8bit INT | 8bit UINT | 16bit INT, high byte first | 16bit INT, low byte first | 16bit UINT, high byte first | 16bit UINT, low byte first | 32bit float, Byte order 1,2,3,4 | 32bit float, Byte order 4,3,2,1 | 32bit float, Byte order 2,1,4,3 | 32bit float, Byte order 3,4,1,2; Default: <b>16bit INT, high byte first</b></td> | + | <td>8bit INT | 8bit UINT | 16bit INT, high byte first | 16bit INT, low byte first | 16bit UINT, high byte first | 16bit UINT, low byte first | 32bit float, Byte order 1,2,3,4 | 32bit float, Byte order 4,3,2,1 | 32bit float, Byte order 2,1,4,3 | 32bit float, Byte order 3,4,1,2; default: <b>16bit INT, high byte first</b></td> |
− | <td>How read data will be stored</td> | + | <td>How read data will be stored.</td> |
| </tr> | | </tr> |
| <tr> | | <tr> |
| <td>Function</td> | | <td>Function</td> |
− | <td>1 | 2 | 3 | 4 | 5 | 6 | 15 | 16; Default: <b>3</b></td> | + | <td>1 | 2 | 3 | 4 | 5 | 6 | 15 | 16; default: <b>3</b></td> |
| <td>A function code specifies the type of register being addressed by a Modbus request. The codes represent these functions:<br> | | <td>A function code specifies the type of register being addressed by a Modbus request. The codes represent these functions:<br> |
| <ul> | | <ul> |
Line 168: |
Line 168: |
| <tr> | | <tr> |
| <td>First Register</td> | | <td>First Register</td> |
− | <td>integer [0..65535]; Default: <b>1</b></td> | + | <td>integer [0..65535]; default: <b>1</b></td> |
− | <td>First Modbus register from which data will be read</td> | + | <td>First Modbus register from which data will be read.</td> |
| </tr> | | </tr> |
| <tr> | | <tr> |
| <td>Number of Registers</td> | | <td>Number of Registers</td> |
− | <td>integer [1..2000]; Default: <b>none</b></td> | + | <td>integer [1..2000]; default: <b>none</b></td> |
− | <td>Number of Modbus registers that will be read during the request</td> | + | <td>Number of Modbus registers that will be read during the request.</td> |
| </tr> | | </tr> |
| <tr> | | <tr> |
| <td>Enabled</td> | | <td>Enabled</td> |
− | <td>yes | no; Default: <b>no</b></td> | + | <td>yes | no; default: <b>no</b></td> |
− | <td>Turns the request ON or OFF</td> | + | <td>Turns the request on or off.</td> |
| </tr> | | </tr> |
| <tr> | | <tr> |
| <td>Test</td> | | <td>Test</td> |
| <td>- (interactive button)</td> | | <td>- (interactive button)</td> |
− | <td>Generates a Modbus request according to given parameters in order to test the request configuration. You must first save the configuration before you can use the Test button</td> | + | <td>Generates a Modbus request according to given parameters in order to test the request configuration. You must first save the configuration before you can use the Test button.</td> |
| </tr> | | </tr> |
| <tr> | | <tr> |
| <td>Delete</td> | | <td>Delete</td> |
| <td>- (interactive button)</td> | | <td>- (interactive button)</td> |
− | <td>Deletes the request</td> | + | <td>Deletes the request.</td> |
| </tr> | | </tr> |
| <tr> | | <tr> |
| <td>Add</td> | | <td>Add</td> |
| <td>- (interactive button)</td> | | <td>- (interactive button)</td> |
− | <td>Adds a new request configuration</td> | + | <td>Adds a new request configuration.</td> |
| </tr> | | </tr> |
| </table> | | </table> |