<pre>
+
ioman.adc.adc0
ioman.adc.adc0  - Analog input
+
  ioman.gpio.dio0
ioman.gpio.dio0 - Configurable input/output (PIN2)
+
ioman.gpio.dio1
ioman.gpio.dio1 - Configurable input/output (PIN3)
+
ioman.gpio.dio2
ioman.gpio.dio2 - Configurable input/output (PIN4)
 
</pre>
 
 
 
Call command <b>ubus call <i>value</i> status </b>:
 
  
 +
Call command <b>ubus call <u>value</u> status </b>:
 
  root@Teltonika-{{{name}}}:~# ubus call ioman.gpio.dio0 status
 
  root@Teltonika-{{{name}}}:~# ubus call ioman.gpio.dio0 status
 
  {
 
  {
Line 21: Line 18:
 
             <li>"value": "<b>0</b>" means low level state.</li>
 
             <li>"value": "<b>0</b>" means low level state.</li>
 
             <li>"value": "<b>1</b>" means high level state.</li>
 
             <li>"value": "<b>1</b>" means high level state.</li>
            <li>"direction": "<b>in</b>" means input state.</li>
 
            <li>"direction": "<b>out</b>" means output state.</li>
 
 
         </ul>
 
         </ul>
 
     </li>
 
     </li>
Line 31: Line 26:
 
     </li>
 
     </li>
 
</ul>
 
</ul>
 
To change input settings, use the <i><b>update</i></b> command and specify a value:
 
 
ubus call ioman.gpio.dio0 update '{"value":"0"}'
 
ubus call ioman.gpio.dio0 update '{"value":"1"}'
 
ubus call ioman.gpio.dio0 update '{"direction":"in"}'
 
ubus call ioman.gpio.dio0 update '{"direction":"out"}'
 

Revision as of 09:40, 4 November 2020

ioman.adc.adc0
ioman.gpio.dio0
ioman.gpio.dio1
ioman.gpio.dio2

Call command ubus call value status :

root@Teltonika-{{{name}}}:~# ubus call ioman.gpio.dio0 status
{
        "value": "0",
        "direction": "out",
        "bi_dir": true,
        "invert_input": false
}
  • dio0 is configurable input / output:
    • "value": "0" means low level state.
    • "value": "1" means high level state.
  • adc0 is analog input:
    • "value": "0.54" means 0.54V.