Difference between revisions of "Template:Networking rut9 manual input output status"

From Teltonika Networks Wiki
(2 intermediate revisions by the same user not shown)
Line 1: Line 1:
{{#ifeq:{{{name}}}|RUT955|
+
<pre>
<pre>
+
ioman.gpio.din1    - 4PIN input
ioman.gpio.din1    - 4PIN input
+
ioman.gpio.dout1  - 4PIN output
ioman.gpio.dout1  - 4PIN output
+
ioman.gpio.din2    - Digital input (only for passive sensors)
ioman.gpio.din2    - Digital input (only for passive sensors)
+
ioman.gpio.dout2  - Galvanically isolated open collector output
ioman.gpio.dout2  - Galvanically isolated open collector output
+
ioman.relay.relay0 - Digital relay output
ioman.relay.relay0 - Digital relay output
+
ioman.gpio.iio    - Digital galvanically isolated input  
ioman.gpio.iio    - Digital galvanically isolated input  
+
ioman.adc.adc0    - Analog input
ioman.adc.adc0    - Analog input
+
ioman.acl.acl0    - Analog Current loop
ioman.acl.acl0    - Analog Current loop
 
</pre>|
 
<pre>
 
ioman.gpio.din1    - 4PIN input
 
ioman.gpio.dout1  - 4PIN output
 
</pre>
 
}}
 
  
 
Call command <b>ubus call <u>value</u> status </b>:
 
Call command <b>ubus call <u>value</u> status </b>:
Line 37: Line 30:
 
             <li>"value": "<b>1</b>" means high level state.</li>
 
             <li>"value": "<b>1</b>" means high level state.</li>
 
         </ul>
 
         </ul>
     </li>{{#ifeq:{{{name}}}|RUT955|
+
     </li>
    <li><b>relay0</b> is the relay:
 
        <ul>
 
            <li>"state": "<b>open</b>" means open relay state.</li>
 
            <li>"state": "<b>closed</b>" means closed relay state.</li>
 
        </ul>
 
    </li>|}}
 
 
</ul>
 
</ul>
 
{{#ifeq:{{{name}}}|RUT955|
 
To change relay settings, use the <i><b>update</i></b> command and specify a state:
 
 
ubus call ioman.relay.relay0 update '{"state":"open"}'
 
ubus call ioman.relay.relay0 update '{"state":"closed"}'
 
|}}
 

Revision as of 15:48, 18 August 2021

 ioman.gpio.din1    - 4PIN input
 ioman.gpio.dout1   - 4PIN output
 ioman.gpio.din2    - Digital input (only for passive sensors)
 ioman.gpio.dout2   - Galvanically isolated open collector output
 ioman.relay.relay0 - Digital relay output
 ioman.gpio.iio     - Digital galvanically isolated input 
 ioman.adc.adc0     - Analog input
 ioman.acl.acl0     - Analog Current loop

Call command ubus call value status :
 root@Teltonika-{{{name}}}:~# ubus call ioman.gpio.din1 status
 {
         "value": "0",
         "direction": "in",
         "bi_dir": false,
         "invert_input": false
 }

  • din1 is the input:
    • "value": "0" means low level state.
    • "value": "1" means high level state.
  • dout1 is the output:
    • "value": "0" means low level state.
    • "value": "1" means high level state.