Difference between revisions of "Template:Networking rutos manual modbus modbus tcp get parameters table"
From Teltonika Networks Wiki
Gytispieze (talk | contribs) |
|||
(12 intermediate revisions by 2 users not shown) | |||
Line 80: | Line 80: | ||
</tr> | </tr> | ||
{{#ifeq:{{{mobile}}}| 1 | | {{#ifeq:{{{mobile}}}| 1 | | ||
− | {{#ifeq:{{{dualsim}}}|1| | + | {{#ifeq:{{{dualsim}}}| 1| |
<tr> | <tr> | ||
<td>Currently active SIM card slot</td> | <td>Currently active SIM card slot</td> | ||
Line 104: | Line 104: | ||
</tr> | </tr> | ||
}} | }} | ||
+ | {{#ifeq:{{{name}}}|RUT955| | ||
+ | <tr> | ||
+ | <td>Digital input (DIN1) state</td> | ||
+ | <td>135</td> | ||
+ | <td>136</td> | ||
+ | <td>2</td> | ||
+ | <td>32 bit integer</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td>Digital galvanically isolated input (DIN2) state</td> | ||
+ | <td>137</td> | ||
+ | <td>138</td> | ||
+ | <td>2</td> | ||
+ | <td>32 bit integer</td> | ||
+ | </tr>|}} | ||
<tr> | <tr> | ||
<td>Current WAN IP address</td> | <td>Current WAN IP address</td> | ||
Line 228: | Line 243: | ||
<td>32 bit unsigned integer</td> | <td>32 bit unsigned integer</td> | ||
</tr> | </tr> | ||
− | {{#ifeq:{{{dualsim}}}|1| | + | {{#ifeq:{{{name}}}|RUT955| |
+ | <tr> | ||
+ | <td>Galvanically isolated open collector output status</td> | ||
+ | <td>201</td> | ||
+ | <td>202</td> | ||
+ | <td>1</td> | ||
+ | <td>16 bit unsigned integer</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td>Relay output status</td> | ||
+ | <td>202</td> | ||
+ | <td>203</td> | ||
+ | <td>1</td> | ||
+ | <td>16 bit unsigned integer</td> | ||
+ | </tr>|}} | ||
+ | {{#ifeq:{{{dualsim}}}| 1| | ||
<tr> | <tr> | ||
<td>Active SIM card</td> | <td>Active SIM card</td> | ||
Line 265: | Line 295: | ||
<td>32 bit unsigned integer</td> | <td>32 bit unsigned integer</td> | ||
</tr> | </tr> | ||
− | {{#ifeq:{{{series}}}|TRB1| | | + | {{#ifeq:{{{name}}}|RUTX12| | |
+ | {{#switch:{{{series}}} | ||
+ | | TRB1|RUT36X|RUT2= | ||
+ | | #default = | ||
<tr> | <tr> | ||
<td>Mobile data received today (SIM2)</td> | <td>Mobile data received today (SIM2)</td> | ||
Line 350: | Line 383: | ||
<td>32 bit unsigned integer</td> | <td>32 bit unsigned integer</td> | ||
</tr> | </tr> | ||
+ | }} | ||
}} | }} | ||
}} | }} | ||
Line 398: | Line 432: | ||
<td>16 bit unsigned integer</td> | <td>16 bit unsigned integer</td> | ||
</tr> | </tr> | ||
+ | |TRB140|TRB141|TRB142|TRB145|RUT300|RUT360= | ||
+ | <tr> | ||
+ | <td>PIN 3 status (4 PIN connector)</td> | ||
+ | <td>324</td> | ||
+ | <td>325</td> | ||
+ | <td>1</td> | ||
+ | <td>16 bit unsigned integer</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td>PIN 4 status (4 PIN connector)</td> | ||
+ | <td>325</td> | ||
+ | <td>326</td> | ||
+ | <td>1</td> | ||
+ | <td>16 bit unsigned integer</td> | ||
+ | </tr> | ||
| | | | ||
<tr> | <tr> | ||
Line 417: | Line 466: | ||
|RUTX= | |RUTX= | ||
|TRB2XX= | |TRB2XX= | ||
+ | |RUT9= | ||
| | | | ||
<tr> | <tr> |
Revision as of 15:36, 20 August 2021
Get Parameters
Modbus parameters are held within registers. Each register contains 2 bytes of information. For simplification, the number of registers for storing numbers is 2 (4 bytes), while the number of registers for storing text information is 16 (32 bytes). The register numbers and corresponding system values are described in the table below:
required value | register address | register number | number of registers | representation |
---|---|---|---|---|
System uptime | 1 | 2 | 2 | 32 bit unsigned integer |
System hostname | 7 | 8 | 16 | Text |
Router serial number | 39 | 40 | 16 | Text |
LAN MAC address | 55 | 56 | 16 | Text |
Router name | 71 | 72 | 16 | Text |
Current WAN IP address | 139 | 140 | 2 | 32 bit unsigned integer |
Digital non-isolated input (4 PIN connector) | 324 | 325 | 1 | 32 bit unsigned integer |
Digital open collector output (4 PIN connector) | 325 | 326 | 1 | 32 bit unsigned integer |
PIN 3 direction | 326 | 327 | 1 | 16 bit unsigned integer |
PIN 4 direction | 327 | 328 | 1 | 16 bit unsigned integer |