Difference between revisions of "Template:Networking rutos manual modbus modbus tcp get parameters table"
From Teltonika Networks Wiki
Gytispieze (talk | contribs) |
|||
(13 intermediate revisions by one other user not shown) | |||
Line 26: | Line 26: | ||
<td>32 bit integer</td> | <td>32 bit integer</td> | ||
</tr> | </tr> | ||
− | |||
<tr> | <tr> | ||
<td>System temperature (in 0.1 °C)</td> | <td>System temperature (in 0.1 °C)</td> | ||
Line 34: | Line 33: | ||
<td>32 bit integer</td> | <td>32 bit integer</td> | ||
</tr> | </tr> | ||
− | |||
}} | }} | ||
<tr> | <tr> | ||
Line 104: | Line 102: | ||
</tr> | </tr> | ||
}} | }} | ||
+ | {{#ifeq:{{{name}}}|RUT955| | ||
+ | <tr> | ||
+ | <td>Digital input (DIN1) state</td> | ||
+ | <td>135</td> | ||
+ | <td>136</td> | ||
+ | <td>2</td> | ||
+ | <td>32 bit integer</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td>Digital galvanically isolated input (DIN2) state</td> | ||
+ | <td>137</td> | ||
+ | <td>138</td> | ||
+ | <td>2</td> | ||
+ | <td>32 bit integer</td> | ||
+ | </tr>|}} | ||
<tr> | <tr> | ||
<td>Current WAN IP address</td> | <td>Current WAN IP address</td> | ||
Line 109: | Line 122: | ||
<td>140</td> | <td>140</td> | ||
<td>2</td> | <td>2</td> | ||
− | <td> | + | <td>8 bit unsigned integer</td> |
</tr> | </tr> | ||
{{#ifeq:{{{analog}}}| 1| | {{#ifeq:{{{analog}}}| 1| | ||
<tr> | <tr> | ||
− | <td>Analog input value</td> | + | <td>Analog input (PIN {{#switch:{{{series}}}|TRB2=11|RUT9=9|TRB1=7}}) value</td> |
<td>141</td> | <td>141</td> | ||
<td>142</td> | <td>142</td> | ||
<td>2</td> | <td>2</td> | ||
− | <td>32 bit integer</td> | + | <td>32 bit unsigned integer</td> |
</tr> | </tr> | ||
}} | }} | ||
Line 154: | Line 167: | ||
<td>180</td> | <td>180</td> | ||
<td>2</td> | <td>2</td> | ||
− | <td>32 bit | + | <td>32 bit float</td> |
</tr> | </tr> | ||
<tr> | <tr> | ||
Line 161: | Line 174: | ||
<td>182</td> | <td>182</td> | ||
<td>2</td> | <td>2</td> | ||
− | <td>32 bit integer</td> | + | <td>32 bit unsigned integer</td> |
</tr> | </tr> | ||
<tr> | <tr> | ||
Line 228: | Line 241: | ||
<td>32 bit unsigned integer</td> | <td>32 bit unsigned integer</td> | ||
</tr> | </tr> | ||
+ | {{#ifeq:{{{name}}}|RUT955| | ||
+ | <tr> | ||
+ | <td>Galvanically isolated open collector output status</td> | ||
+ | <td>201</td> | ||
+ | <td>202</td> | ||
+ | <td>1</td> | ||
+ | <td>16 bit unsigned integer</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td>Relay output status</td> | ||
+ | <td>202</td> | ||
+ | <td>203</td> | ||
+ | <td>1</td> | ||
+ | <td>16 bit unsigned integer</td> | ||
+ | </tr>|}} | ||
{{#ifeq:{{{dualsim}}}| 1| | {{#ifeq:{{{dualsim}}}| 1| | ||
<tr> | <tr> | ||
Line 234: | Line 262: | ||
<td>206</td> | <td>206</td> | ||
<td>1</td> | <td>1</td> | ||
− | <td> | + | <td>16 bit unsigned integer</td> |
</tr> | </tr> | ||
}} | }} | ||
Line 265: | Line 293: | ||
<td>32 bit unsigned integer</td> | <td>32 bit unsigned integer</td> | ||
</tr> | </tr> | ||
− | {{#ifeq:{{{series}}}|TRB1| | | + | {{#ifeq:{{{name}}}|RUTX12| | |
+ | {{#switch:{{{series}}} | ||
+ | | TRB1|RUT36X|RUT2= | ||
+ | | #default = | ||
<tr> | <tr> | ||
<td>Mobile data received today (SIM2)</td> | <td>Mobile data received today (SIM2)</td> | ||
Line 350: | Line 381: | ||
<td>32 bit unsigned integer</td> | <td>32 bit unsigned integer</td> | ||
</tr> | </tr> | ||
+ | }} | ||
}} | }} | ||
}} | }} | ||
{{#switch:{{{name}}} | {{#switch:{{{name}}} | ||
− | | | + | |TCR100= |
− | | | + | |TRB245|TRB255= |
− | |||
− | |TRB255 | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
<tr> | <tr> | ||
<td>PIN 3 status</td> | <td>PIN 3 status</td> | ||
Line 393: | Line 401: | ||
<td>16 bit unsigned integer</td> | <td>16 bit unsigned integer</td> | ||
</tr> | </tr> | ||
− | + | |TRB140|TRB141|TRB142|TRB145|RUT300|RUT360= | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |TRB140|TRB141|TRB142|TRB145= | ||
<tr> | <tr> | ||
<td>PIN 3 status (4 PIN connector)</td> | <td>PIN 3 status (4 PIN connector)</td> | ||
Line 421: | Line 422: | ||
<td>325</td> | <td>325</td> | ||
<td>1</td> | <td>1</td> | ||
− | <td> | + | <td>16 bit unsigned integer</td> |
</tr> | </tr> | ||
<tr> | <tr> | ||
Line 428: | Line 429: | ||
<td>326</td> | <td>326</td> | ||
<td>1</td> | <td>1</td> | ||
− | <td> | + | <td>16 bit unsigned integer</td> |
</tr> | </tr> | ||
}} | }} | ||
{{#switch:{{{series}}} | {{#switch:{{{series}}} | ||
− | | | + | |TCR1= |
− | | | + | |RUTX|TRB2|RUT9|RUT2|RUT2M= |
− | |RUT9= | ||
| | | | ||
<tr> | <tr> | ||
Line 451: | Line 451: | ||
</tr> | </tr> | ||
}} | }} | ||
− | |||
<tr> | <tr> | ||
<td> Modem ID </td> | <td> Modem ID </td> | ||
Line 459: | Line 458: | ||
<td>Text</td> | <td>Text</td> | ||
</tr> | </tr> | ||
+ | {{#ifeq:{{{series}}}|TRB2| | ||
+ | <tr> | ||
+ | <td>PIN 2 status</td> | ||
+ | <td>336</td> | ||
+ | <td>337</td> | ||
+ | <td>1</td> | ||
+ | <td>16 bit unsigned integer</td> | ||
+ | </tr> | ||
}} | }} | ||
{{#ifeq:{{{name}}}|TRB141| | {{#ifeq:{{{name}}}|TRB141| | ||
Line 514: | Line 521: | ||
<td>344</td> | <td>344</td> | ||
<td>345</td> | <td>345</td> | ||
+ | <td>1</td> | ||
+ | <td>16 bit unsigned integer</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td> ACL activity </td> | ||
+ | <td>345</td> | ||
+ | <td>346</td> | ||
<td>1</td> | <td>1</td> | ||
<td>16 bit unsigned integer</td> | <td>16 bit unsigned integer</td> | ||
Line 521: | Line 535: | ||
<td>346</td> | <td>346</td> | ||
<td>347</td> | <td>347</td> | ||
− | <td> | + | <td>2</td> |
− | <td>32 bit | + | <td>32 bit float</td> |
</tr> | </tr> | ||
}} | }} | ||
Line 534: | Line 548: | ||
</tr> | </tr> | ||
}} | }} | ||
+ | <tr> | ||
+ | <td> Unix timestamp </td> | ||
+ | <td>364</td> | ||
+ | <td>365</td> | ||
+ | <td>2</td> | ||
+ | <td>32 bit unsigned integer</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td> Local ISO time </td> | ||
+ | <td>366</td> | ||
+ | <td>367</td> | ||
+ | <td>12</td> | ||
+ | <td>Text</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td> UTC time </td> | ||
+ | <td>378</td> | ||
+ | <td>389</td> | ||
+ | <td>12</td> | ||
+ | <td>Text</td> | ||
+ | </tr> | ||
</table> | </table> |
Revision as of 12:41, 13 April 2022
Get Parameters
Modbus parameters are held within registers. Each register contains 2 bytes of information. For simplification, the number of registers for storing numbers is 2 (4 bytes), while the number of registers for storing text information is 16 (32 bytes). The register numbers and corresponding system values are described in the table below:
required value | register address | register number | number of registers | representation |
---|---|---|---|---|
System uptime | 1 | 2 | 2 | 32 bit unsigned integer |
System hostname | 7 | 8 | 16 | Text |
Router serial number | 39 | 40 | 16 | Text |
LAN MAC address | 55 | 56 | 16 | Text |
Router name | 71 | 72 | 16 | Text |
Current WAN IP address | 139 | 140 | 2 | 8 bit unsigned integer |
Digital non-isolated input (4 PIN connector) | 324 | 325 | 1 | 16 bit unsigned integer |
Digital open collector output (4 PIN connector) | 325 | 326 | 1 | 16 bit unsigned integer |
PIN 3 direction | 326 | 327 | 1 | 16 bit unsigned integer |
PIN 4 direction | 327 | 328 | 1 | 16 bit unsigned integer |
Modem ID | 328 | 329 | 8 | Text |
Unix timestamp | 364 | 365 | 2 | 32 bit unsigned integer |
Local ISO time | 366 | 367 | 12 | Text |
UTC time | 378 | 389 | 12 | Text |