Difference between revisions of "Template:Networking trb140 faq power consumption table"
From Teltonika Networks Wiki
Gytispieze (talk | contribs) |
|||
(One intermediate revision by the same user not shown) | |||
Line 2: | Line 2: | ||
<tr style="font-weight:bold"> | <tr style="font-weight:bold"> | ||
<th width=800>Test type</th> | <th width=800>Test type</th> | ||
− | <th width=150 | + | <th width=150>Current (mA)</span></th> |
− | <th width= | + | <th width=150>Power consumption (W)</th> |
</tr> | </tr> | ||
<tr> | <tr> | ||
<td>Idle, no SIM card inserted (9 V)</td> | <td>Idle, no SIM card inserted (9 V)</td> | ||
− | <td | + | <td><b>210</b></td> |
− | <td | + | <td><b>1.89</b></td> |
</tr> | </tr> | ||
<tr> | <tr> | ||
<td>Idle, no SIM card inserted (12 V)</td> | <td>Idle, no SIM card inserted (12 V)</td> | ||
− | <td | + | <td><b>180</b></td> |
− | <td | + | <td><b>2.16</b></td> |
</tr> | </tr> | ||
<tr> | <tr> | ||
<td>Idle, no SIM card inserted (24 V)</td> | <td>Idle, no SIM card inserted (24 V)</td> | ||
− | <td | + | <td><b>90</b></td> |
− | <td | + | <td><b>2.16</b></td> |
</tr> | </tr> | ||
</table> | </table> | ||
Line 26: | Line 26: | ||
<tr style="font-weight:bold"> | <tr style="font-weight:bold"> | ||
<th width=800>Test type</th> | <th width=800>Test type</th> | ||
− | <th width=150 | + | <th width=150>Current (mA)</span></th> |
− | <th width= | + | <th width=150>Power consumption (W)</th> |
</tr> | </tr> | ||
<tr> | <tr> | ||
<td>Idle + mobile data on <sup><small>1</small></sup> (9 V)</td> | <td>Idle + mobile data on <sup><small>1</small></sup> (9 V)</td> | ||
− | <td | + | <td><b>280</b></td> |
− | <td | + | <td><b>2.52</b></td> |
</tr> | </tr> | ||
<tr> | <tr> | ||
<td>Idle + mobile data on <sup><small>1</small></sup> (12 V)</td> | <td>Idle + mobile data on <sup><small>1</small></sup> (12 V)</td> | ||
− | <td | + | <td><b>230</b></td> |
− | <td | + | <td><b>2.76</b></td> |
</tr> | </tr> | ||
<tr> | <tr> | ||
<td>Idle + mobile data on <sup><small>1</small></sup> (24 V)</td> | <td>Idle + mobile data on <sup><small>1</small></sup> (24 V)</td> | ||
− | <td | + | <td><b>110</b></td> |
− | <td | + | <td><b>2.64</b></td> |
</tr> | </tr> | ||
</table> | </table> | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
Line 74: | Line 51: | ||
<tr style="font-weight:bold"> | <tr style="font-weight:bold"> | ||
<th width=800>Test type</th> | <th width=800>Test type</th> | ||
− | <th width=150 | + | <th width=150>Current (mA)</span></th> |
− | <th width= | + | <th width=150>Power consumption (W)</th> |
</tr> | </tr> | ||
<tr> | <tr> | ||
− | <td>Max speed LTE transmission + 1 LAN device connected <sup><small>2</small></sup> + high CPU load <sup><small>3</small></sup> (9V)</td> | + | <td>Max speed LTE transmission + 1 LAN device connected <sup><small>2</small></sup> + high CPU load <sup><small>3</small></sup> + M-Bus (Data to Server) (9V)</td> |
− | <td | + | <td><b>510</b></td> |
− | <td | + | <td><b>4.59</b></td> |
</tr> | </tr> | ||
<tr> | <tr> | ||
− | <td>Max speed LTE transmission + 1 LAN device connected <sup><small>2</small></sup> + high CPU load <sup><small>3</small></sup> (12 V)</td> | + | <td>Max speed LTE transmission + 1 LAN device connected <sup><small>2</small></sup> + high CPU load <sup><small>3</small></sup> + M-Bus (Data to Server) (12 V)</td> |
− | <td | + | <td><b>410</b></td> |
− | <td | + | <td><b>4.92</b></td> |
</tr> | </tr> | ||
<tr> | <tr> | ||
− | <td>Max speed LTE transmission + 1 LAN device connected <sup><small>2</small></sup> + high CPU load <sup><small>3</small></sup> (24 V)</td> | + | <td>Max speed LTE transmission + 1 LAN device connected <sup><small>2</small></sup> + high CPU load <sup><small>3</small></sup> + M-Bus (Data to Server) (24 V)</td> |
− | <td | + | <td><b>220</b></td> |
− | <td | + | <td><b>5.28</b></td> |
</tr> | </tr> | ||
</table> | </table> | ||
− | |||
<small><sup><small>1</small></sup> - Only mobile data connection established with no additional traffic.</small> <br> | <small><sup><small>1</small></sup> - Only mobile data connection established with no additional traffic.</small> <br> | ||
− | <small><sup><small>2</small></sup> - Data streams between | + | <small><sup><small>2</small></sup> - Data streams between TRB143 and other connected LAN devices created using iPerf.</small> <br> |
<small><sup><small>3</small></sup> - Load created using ''md5sum'' (calculation and verification of 128-bit MD5 hashes). </small> <br> | <small><sup><small>3</small></sup> - Load created using ''md5sum'' (calculation and verification of 128-bit MD5 hashes). </small> <br> | ||
<small>Power consumption may differ due to mobile data transmission speed, testing environment and conditions.</small> | <small>Power consumption may differ due to mobile data transmission speed, testing environment and conditions.</small> |
Revision as of 11:29, 3 June 2022
Test type | Current (mA) | Power consumption (W) |
---|---|---|
Idle, no SIM card inserted (9 V) | 210 | 1.89 |
Idle, no SIM card inserted (12 V) | 180 | 2.16 |
Idle, no SIM card inserted (24 V) | 90 | 2.16 |
Test type | Current (mA) | Power consumption (W) |
---|---|---|
Idle + mobile data on 1 (9 V) | 280 | 2.52 |
Idle + mobile data on 1 (12 V) | 230 | 2.76 |
Idle + mobile data on 1 (24 V) | 110 | 2.64 |
Test type | Current (mA) | Power consumption (W) |
---|---|---|
Max speed LTE transmission + 1 LAN device connected 2 + high CPU load 3 + M-Bus (Data to Server) (9V) | 510 | 4.59 |
Max speed LTE transmission + 1 LAN device connected 2 + high CPU load 3 + M-Bus (Data to Server) (12 V) | 410 | 4.92 |
Max speed LTE transmission + 1 LAN device connected 2 + high CPU load 3 + M-Bus (Data to Server) (24 V) | 220 | 5.28 |
1 - Only mobile data connection established with no additional traffic.
2 - Data streams between TRB143 and other connected LAN devices created using iPerf.
3 - Load created using md5sum (calculation and verification of 128-bit MD5 hashes).
Power consumption may differ due to mobile data transmission speed, testing environment and conditions.