Difference between revisions of "Template:Networking tsw304 faq power consumption table"

From Teltonika Networks Wiki
(Created page with "<table class="nd-othertables_3"> <tr style="font-weight:bold"> <th width=800>Test type</th> <th width=150>Current (mA)</span></th> <th width=160>Pow...")
 
(Created page with "<table class="nd-othertables_3"> <tr style="font-weight:bold"> <th width=800>Test type</th> <th width=150>Current (mA)</span></th> <th width=160>Pow...")
 
(No difference)

Latest revision as of 16:04, 7 June 2022

Test type Current (mA) Power consumption (W)
Idle (9 V) 28 0.25
Idle (12 V) 22 0.26
Idle (24 V) 11 0.26


Test type Current (mA) Power consumption (W)
2 LAN devices connected + heavy data traffic1 (9 V) 103 0.92
2 LAN devices connected + heavy data traffic1 (12 V) 78 0.93
2 LAN devices connected + heavy data traffic1 (24 V) 40 0.96


Test type Current (mA) Power consumption (W)
3 LAN devices connected + heavy data traffic1 (9 V) 143 1.28
3 LAN devices connected + heavy data traffic1 (12 V) 108 1.29
3 LAN devices connected + heavy data traffic1 (24 V) 54 1.29


Test type Current (mA) Power consumption (W)
4 LAN devices connected + heavy data traffic1 (9 V) 158 1.42
4 LAN devices connected + heavy data traffic1 (12 V) 119 1.42
4 LAN devices connected + heavy data traffic1 (24 V) 60 1.44

1 - Data streams between devices were created using iPerf.
Power consumption may differ due to testing environment and conditions.