Template:Networking tsw1xx manual powering options: Difference between revisions

From Teltonika Networks Wiki
No edit summary
No edit summary
(9 intermediate revisions by 3 users not shown)
Line 3: Line 3:
__TOC__
__TOC__


The switch has a {{#switch:{{{name}}}|TSW100=4|TSW101=2}} pin power socket and can be powered by a {{#switch:{{{name}}}|TSW100=7-57|TSW101|TSW114=9-30}} VDC power supply unit (PSU). Refer to the image below for the power socket's pinout information:  
The switch has a {{#switch:{{{name}}}|TSW100=4|TSW101=2}} pin power socket and can be powered by a {{#switch:{{{name}}}|TSW100=7-57|TSW101=9-30}} VDC power supply unit (PSU). Refer to the image below for the power socket's pinout information:  


==Power socket==
==Power socket==
Line 12: Line 12:


{{#switch:{{{name}}}
{{#switch:{{{name}}}
  | TSW100=If you decide not to use the standard 50 VDC power supply unit and want to power the device with other voltages (7-57 VDC), please make sure that you choose a power supply of high quality. Some power supplies can produce voltage peaks significantly higher than the declared output voltage, especially during connection and disconnection.  
  | TSW100=If you decide not to use the standard 50 VDC power supply unit and want to power the device with other voltages (7-57 VDC), please make sure that you choose a power supply of high quality, especially when using higher voltages (50-57 VDC). Some power supplies can produce voltage peaks significantly higher than the declared output voltage, especially during connection and disconnection.  


While the device is designed to accept input voltage of up to 57 VDC peaks, high voltage power supplies can harm the device. If you want to use high voltage power supplies it is recommended to also use additional safety equipment to suppress voltage peaks from the power supply.
While the device is designed to accept input voltage of up to 57 VDC peaks, high voltage power supplies can harm the device. If you want to use high voltage power supplies it is recommended to also use additional safety equipment to suppress voltage peaks from the power supply.
Line 19: Line 19:


<b>{{{name}}} Batch 001 onwards:</b> use UTP (Unshielded) cable only when connecting non-Active PoE (non-803.3af/at) equipment or make sure that these devices support voltages, provided by TSW100 PSU.
<b>{{{name}}} Batch 001 onwards:</b> use UTP (Unshielded) cable only when connecting non-Active PoE (non-803.3af/at) equipment or make sure that these devices support voltages, provided by TSW100 PSU.
  | TSW101|TSW114 =  
  | TSW101 =  
}}
 
{{#switch:{{{name}}}
| TSW100|TSW101= ==Disclaimer: {{{name}}} and Passive PoE devices==
 
There are a couple of options to stay safe when using {{{name}}} '''Active PoE''' with devices that only support '''Passive PoE''':
 
* Connect {{{name}}} and Passive PoE device only via non-PoE Ethernet ports (for example, '''do not''' use {{{name}}} PoE ports with '''LAN1''' ports on Teltonika devices).
* If there is a need to use '''LAN1''' port on the end device, make sure that {{{name}}} and the end device are '''powered from different voltage sources''' (for example, power both devices from different PSUs, or different batteries).
 
If {{{name}}} and a Passive PoE device are connected with common ground, '''do not use LAN1 port''', other ports can be used (refer to image below):
 
[[File:Passive - Active PoE common ground connection.jpg|400px|border|class=tlt-border]]
}}
 
{{#ifeq:{{{passive_poe}}}|1|
{{Template: networking_device_manual_powering_options_passive_poe
  | series    = {{{series}}}
  | file_lan1 = {{{file_lan1}}}
  | size_lan1 = {{{size_lan1}}}
}}|}}
{{#switch: {{{series}}} | #default =
{{Template: networking_device_manual_powering_options_ground_loops_switches
      | series    = {{{series}}}
      | name      = {{{name}}}
}}
}}
}}


[[Category:{{{name}}} Manual]]
[[Category:{{{name}}} Manual]]

Revision as of 11:03, 22 July 2022

This chapter contains information on powering options supported by {{{name}}} switch.

The switch has a pin power socket and can be powered by a VDC power supply unit (PSU). Refer to the image below for the power socket's pinout information:

Power socket

{{Template: Networking_{{{series}}}_manual_power_socket_pinout | name = {{{name}}} }}


[[Category:{{{name}}} Manual]]