Difference between revisions of "Template:Networking rutos manual modbus modbus tcp get parameters table"
From Teltonika Networks Wiki
Gytispieze (talk | contribs) |
Gytispieze (talk | contribs) |
||
Line 112: | Line 112: | ||
</tr> | </tr> | ||
}} | }} | ||
− | {{# | + | {{#switch:{{{name}}} |
+ | | RUT955|RUT956= | ||
<tr> | <tr> | ||
<td>Digital input (DIN1) state</td> | <td>Digital input (DIN1) state</td> | ||
Line 579: | Line 580: | ||
<td>Text</td> | <td>Text</td> | ||
</tr> | </tr> | ||
+ | <tr> | ||
+ | <td> LAN IP </td> | ||
+ | <td>396</td> | ||
+ | <td>397</td> | ||
+ | <td>2</td> | ||
+ | <td>16 bit unsigned integer</td> | ||
+ | </tr>{{#ifeq:{{{mobile}}}|1| | ||
+ | <tr> | ||
+ | <td> Add SMS </td> | ||
+ | <td>397</td> | ||
+ | <td>398</td> | ||
+ | <td>12</td> | ||
+ | <td>Text</td> | ||
+ | </tr> | ||
+ | }} | ||
</table> | </table> |
Revision as of 16:03, 21 November 2022
Get Parameters
Modbus parameters are held within registers. Each register contains 2 bytes of information. For simplification, the number of registers for storing numbers is 2 (4 bytes), while the number of registers for storing text information is 16 (32 bytes).
The register numbers and corresponding system values are described in the table below:
required value | register address | register number | number of registers | representation |
---|---|---|---|---|
System uptime | 1 | 2 | 2 | 32 bit unsigned integer |
System hostname | 7 | 8 | 16 | Text |
Router serial number | 39 | 40 | 16 | Text |
LAN MAC address | 55 | 56 | 16 | Text |
Router name | 71 | 72 | 16 | Text |
Current WAN IP address | 139 | 140 | 2 | 8 bit unsigned integer |
Digital non-isolated input | 324 | 325 | 1 | 16 bit unsigned integer |
Digital open collector output | 325 | 326 | 1 | 16 bit unsigned integer |
PIN 3 direction | 326 | 327 | 1 | 16 bit unsigned integer |
PIN 4 direction | 327 | 328 | 1 | 16 bit unsigned integer |
Modem ID | 328 | 329 | 8 | Text |
Unix timestamp | 364 | 365 | 2 | 32 bit unsigned integer |
Local ISO time | 366 | 367 | 12 | Text |
UTC time | 378 | 389 | 12 | Text |
LAN IP | 396 | 397 | 2 | 16 bit unsigned integer |