Difference between revisions of "Template:Networking trb2 manual input output status"
(Created page with " ioman.adc.adc0 ioman.gpio.dio0 ioman.gpio.dio1 ioman.gpio.dio2 Call command <b>ubus call <u>value</u> status </b>: root@Teltonika-{{{name}}}:~# ubus call ioman.gpio.dio0...") |
Gytispieze (talk | contribs) |
||
(2 intermediate revisions by 2 users not shown) | |||
Line 1: | Line 1: | ||
− | + | <pre> | |
− | + | ioman.adc.adc0 - Analog input | |
− | + | ioman.gpio.dio0 - Configurable input/output (PIN2) | |
− | + | ioman.gpio.dio1 - Configurable input/output (PIN3) | |
+ | ioman.gpio.dio2 - Configurable input/output (PIN4) | ||
+ | </pre> | ||
+ | |||
+ | Call command <b>ubus call <i>value</i> status </b>: | ||
− | |||
root@Teltonika-{{{name}}}:~# ubus call ioman.gpio.dio0 status | root@Teltonika-{{{name}}}:~# ubus call ioman.gpio.dio0 status | ||
{ | { | ||
Line 18: | Line 21: | ||
<li>"value": "<b>0</b>" means low level state.</li> | <li>"value": "<b>0</b>" means low level state.</li> | ||
<li>"value": "<b>1</b>" means high level state.</li> | <li>"value": "<b>1</b>" means high level state.</li> | ||
+ | <li>"direction": "<b>in</b>" means input state.</li> | ||
+ | <li>"direction": "<b>out</b>" means output state.</li> | ||
</ul> | </ul> | ||
</li> | </li> | ||
Line 26: | Line 31: | ||
</li> | </li> | ||
</ul> | </ul> | ||
+ | |||
+ | To change input settings, use the <i><b>update</i></b> command and specify a value: | ||
+ | |||
+ | ubus call ioman.gpio.dio0 update '{"value":"0"}' | ||
+ | ubus call ioman.gpio.dio0 update '{"value":"1"}' | ||
+ | ubus call ioman.gpio.dio0 update '{"direction":"in"}' | ||
+ | ubus call ioman.gpio.dio0 update '{"direction":"out"}' |
Latest revision as of 08:12, 19 August 2021
ioman.adc.adc0 - Analog input ioman.gpio.dio0 - Configurable input/output (PIN2) ioman.gpio.dio1 - Configurable input/output (PIN3) ioman.gpio.dio2 - Configurable input/output (PIN4)
Call command ubus call value status :
root@Teltonika-{{{name}}}:~# ubus call ioman.gpio.dio0 status { "value": "0", "direction": "out", "bi_dir": true, "invert_input": false }
- dio0 is configurable input / output:
- "value": "0" means low level state.
- "value": "1" means high level state.
- "direction": "in" means input state.
- "direction": "out" means output state.
- adc0 is analog input:
- "value": "0.54" means 0.54V.
To change input settings, use the update command and specify a value:
ubus call ioman.gpio.dio0 update '{"value":"0"}' ubus call ioman.gpio.dio0 update '{"value":"1"}' ubus call ioman.gpio.dio0 update '{"direction":"in"}' ubus call ioman.gpio.dio0 update '{"direction":"out"}'