Difference between revisions of "Template:Networking tsw1xx manual powering options"

From Teltonika Networks Wiki
 
(4 intermediate revisions by 2 users not shown)
Line 12: Line 12:
  
 
{{#switch:{{{name}}}
 
{{#switch:{{{name}}}
  | TSW100=If you decide not to use the standard 50 VDC power supply unit and want to power the device with other voltages (7-57 VDC), please make sure that you choose a power supply of high quality, especially when using higher voltages (50-57 VDC). Some power supplies can produce voltage peaks significantly higher than the declared output voltage, especially during connection and disconnection.  
+
  | TSW100=If you decide not to use the standard 50 VDC power supply unit and want to power the device with other voltages (7-57 VDC), please make sure that you choose a power supply of high quality. Some power supplies can produce voltage peaks significantly higher than the declared output voltage, especially during connection and disconnection.  
  
 
While the device is designed to accept input voltage of up to 57 VDC peaks, high voltage power supplies can harm the device. If you want to use high voltage power supplies it is recommended to also use additional safety equipment to suppress voltage peaks from the power supply.
 
While the device is designed to accept input voltage of up to 57 VDC peaks, high voltage power supplies can harm the device. If you want to use high voltage power supplies it is recommended to also use additional safety equipment to suppress voltage peaks from the power supply.
Line 33: Line 33:
  
 
[[File:Passive - Active PoE common ground connection.jpg|400px|border|class=tlt-border]]
 
[[File:Passive - Active PoE common ground connection.jpg|400px|border|class=tlt-border]]
 +
}}
  
 
{{#ifeq:{{{passive_poe}}}|1|
 
{{#ifeq:{{{passive_poe}}}|1|
Line 40: Line 41:
 
   | size_lan1 = {{{size_lan1}}}
 
   | size_lan1 = {{{size_lan1}}}
 
}}|}}
 
}}|}}
 +
{{#switch: {{{series}}} | #default =
 +
{{Template: networking_device_manual_powering_options_ground_loops_switches
 +
      | series    = {{{series}}}
 +
      | name      = {{{name}}}
 +
}}
 +
}}
  
 
[[Category:{{{name}}} Manual]]
 
[[Category:{{{name}}} Manual]]

Latest revision as of 10:22, 27 June 2024

This chapter contains information on powering options supported by {{{name}}} switch.

The switch has a pin power socket and can be powered by a VDC power supply unit (PSU). Refer to the image below for the power socket's pinout information:

Power socket

{{Template: Networking_{{{series}}}_manual_power_socket_pinout | name = {{{name}}} }}




Ground loops

Do not connect the power supply negative terminal of our device to the chassis or earth exclusively.

This connection could cause ground loops. For example, if the antenna shield and power supply negative terminal are connected to the chassis or earth, it forms a ground loop, therefore unwanted current could flow through a device PCB ground and may cause damage.

In networking switches connecting our device power supply negative terminal to the chassis or earth could cause damage to other devices connected to the switch or unintentional power up of other devices.

Networking rutos manual device recovery option ground loops v1.png