= Safety information = | |||
Before starting operating the device, please review recommendations and precautions to minimize the possibility of accidents. Safety precautions presented are supplementary and subject to the local safety regulations. When various operations are executed on the device, the user must fully follow the safety instructions and recommendations provided with the device. | Before starting operating the device, please review recommendations and precautions to minimize the possibility of accidents. Safety precautions presented are supplementary and subject to the local safety regulations. When various operations are executed on the device, the user must fully follow the safety instructions and recommendations provided with the device. | ||
== General == | |||
{| class="wikitable" | {| class="wikitable" | ||
|- style="font-weight:bold;" | |- style="font-weight:bold;" | ||
| Line 36: | Line 36: | ||
|} | |} | ||
* PoE operates properly only when connected power supply outputs 44 V or higher voltage. | <span class="asterisk">*</span> PoE operates properly only when connected power supply outputs 44 V or higher voltage. | ||
** Order code dependant. | |||
<span class="asterisk">**</span> Order code dependant. | |||
=Quick Start Guide= | |||
== Front view == | |||
<br> | |||
[[File:TSW202_Front_view_Schematics_v1.png|center|800 px|link=Special:FilePath/TSW202_Front_view_Schematics_v1.png]] | |||
== Back view == | |||
<br> | |||
[[File:TSW202_Back_view_Schematics_v1.png|center|580 px|link=Special:FilePath/TSW202_Back_view_Schematics_v1.png]] | |||
== Connectors == | |||
<br> | |||
'''POWER SOCKET PINOUT''' | |||
<br> | |||
[[File:2-pin_industrial_power_socket_v1.png|center|500 px|link=Special:FilePath/2-pin_industrial_power_socket_v1.png]] | |||
<br> | |||
'''RJ45 LED MEANING''' | |||
<br> | |||
[[File:Networks_RJ45 ports_v1.png|center|700 px|link=Special:FilePath/Networks_RJ45 ports_v1.png]] | |||
<br> | |||
'''SFP LED MEANING''' | |||
<br> | |||
[[File:Networks_SFP_ports_v1.png|center|770 px|link=Special:FilePath/Networks_SFP_ports_v1.png]] | |||
== Video Quick Start Guide == | |||
Need some help setting up your Teltonika Networks TSW202 PoE+ managed switch? Watch our quick start guide video and follow the step-by-step instructions to easily set up your new router for operation. | |||
<youtube>od1y-kfPGNk</youtube> | |||
<br> | |||
== Hardware installation == | |||
<br> | |||
<table> | |||
<tr> | |||
<td style="vertical-align: top; margin: 10px; padding-bottom: 25px;">[[File:TSW202_Hardware_installation_step_1.png|left|link=Special:FilePath/TSW202_Hardware_installation_step_1.png]]</td> | |||
<td style="vertical-align: top; margin: 0px; padding-left: 25px; padding-bottom: 25px;">[[File:TSW202_Hardware_installation_step_2.png|right|link=Special:FilePath/TSW202_Hardware_installation_step_2.png]]</td> | |||
</tr> | |||
</table> | |||
== Login to device (PROFINET Disabled) == | |||
=== Windows - Teltonika Profinet Configurator === | |||
This guide walks you through installing and using the Teltonika PROFINET Configurator on Windows 11 to set up the switch. Once a valid IP address and subnet mask are assigned, the WebUI becomes accessible. | |||
[[File:Profinet_configurator_windows_91.png|800px|link=Special:FilePath/Profinet_configurator_windows_91.png]] | |||
=== <span class="mw-customtoggle-profinet">▶️ Click to expand details</span> === | |||
<div class="mw-collapsible mw-collapsed" id="mw-customcollapsible-profinet"> | |||
{{Template:Profinet_configurator_windows | |||
| name = TSW202 | |||
}} | |||
</div> | |||
<br> | |||
=== Linux (Ubuntu) - Teltonika Profinet Configurator === | |||
---- | |||
This guide walks you through installing and using the Teltonika PROFINET Configurator on Linux (Ubuntu) to set up the switch. Once a valid IP address and subnet mask are assigned, the WebUI becomes accessible. | |||
[[File:Profinet_configurator_ubuntu_71.png|800px|link=Special:FilePath/Profinet_configurator_ubuntu_71.png]] | |||
=== <span class="mw-customtoggle-profinet2">▶️ Click to expand details</span> === | |||
<div class="mw-collapsible mw-collapsed" id="mw-customcollapsible-profinet2"> | |||
{{Template:Profinet_configurator_ubuntu | |||
| name = TSW202 | |||
}} | |||
</div> | |||
<br> | |||
== Login to device (PROFINET Enabled) == | |||
<br> | |||
'''Disclaimer:''' This solution works only with firmware versions before '''TSW2_PROFINET_R_02.01.07_WEBUI'''. | |||
<table> | |||
<tr> | |||
<td style="border-bottom: 1px solid #e8e8e8; vertical-align: top; margin: 10px; padding-bottom: 25px;">1. Ensure the Network connection is Enabled. Go to Start — Control Panel — Network and Internet — Network and Sharing Center. Click on the '''Change adapter settings''' in the left panel, then right-click on Network Adapter, and select Enable.</td> | |||
<td style="border-bottom: 1px solid #e8e8e8; vertical-align: top; width: 680px; margin: 10px; padding-bottom: 25px;">[[File:Configure-your-network-1.jpg|right|600 px]]</td> | |||
</tr> | |||
<tr> | |||
<td style="border-bottom: 1px solid #e8e8e8; vertical-align: top; padding-top: 25px;"> | |||
2. Right-click on Network Adapter and select Properties. Then select '''Internet Protocol Version 4''' and click Properties.<br><br> | |||
3. Select '''Obtain an IP address automatically''' to enable DHCP.<br><br> | |||
4. Click OK to save your settings. | |||
</td> | |||
<td style="border-bottom: 1px solid #e8e8e8; vertical-align: top; padding-top: 25px;">[[File:DHCP_auto_ip_windows.png|right|500x500px]]</td> | |||
</tr> | |||
</table> | |||
<br> | |||
<table style="width: 100%;"> | |||
<tr> | |||
<td colspan="2" style="border-bottom: 1px solid #e8e8e8; vertical-align: top; margin: 10px; padding-bottom: 25px;"> | |||
5. Connect your PC and the TSW212 to a DHCP-enabled router or switch. Allow the TSW212 to obtain an IP address from DHCP. | |||
<br><br> | |||
6. Identify the TSW212 IP address by:<br> | |||
* Log into your router’s DHCP lease table and look for a device named '''TSW212'''.<br> | |||
* Alternatively, use a network scanner such as '''Advanced IP Scanner''' or '''Angry IP Scanner''' (for Windows), or '''nmap''' (Linux) to discover active devices on the network.<br> | |||
* You can identify the correct device by its '''device name''' or '''MAC address''', which is printed on the switch label. | |||
</td> | |||
</tr> | |||
</table> | |||
<td style="border-bottom: 1px solid #e8e8e8; vertical-align: top; padding-top: 25px;"> | |||
7. To enter the managed switch's Web interface (WebUI), type the discovered IP address (e.g., <nowiki>http://192.168.x.x</nowiki>) into the URL field of your Internet browser.<br><br> | |||
8. When prompted for authentication, enter the username '''admin''' and password '''admin''' (unless otherwise specified on the device label). | |||
</td> | |||
<td style="border-bottom: 1px solid #e8e8e8; vertical-align: top; width: 680px; margin: 10px; padding-bottom: 25px;"></td> | |||
</tr> | |||
<tr> | |||
<td style="border-bottom: 1px solid #e8e8e8; vertical-align: top; padding-top: 25px;"> | |||
9. After logging in, set a new password for security reasons. You will not be able to interact with the managed switch's WebUI until the default password is changed. The new password must consist of a minimum of '''8 characters''', including at least one uppercase letter, one lowercase letter, and one digit.<br> | |||
</td> | |||
</tr> | |||
</table> | |||
== PoE standards == | |||
This device uses PoE alternative B. | |||
* PoE Alternative A for '''TSW202''' was introduced earlier batches (see below) used PoE Alternative B: | |||
** 802.3af and 802.3at '''Alternative A''' (Batch 15 and all batches from Batch 17 onward) | |||
** 802.3af and 802.3at '''Alternative B''' (Batches 1–14 and Batch 16) | |||
==== The difference between PoE alternative A and alternative B ==== | |||
'''Alternative A:''' | |||
802.3af and 802.3at Alternative A connection. The power sourcing equipment applies a positive voltage to pins 1-2 and a negative voltage to pins 3-6. | |||
{{Template: Alternative_A_Table}} | |||
'''Alternative B:''' | |||
802.3af and 802.3at Alternative B connection. The power sourcing equipment applies a positive voltage to pins 4-5 and a negative voltage to pins 7-8. | |||
{{Template: Alternative_B_Table}} | |||
=Compliance= | |||
TSW202 must be used in compliance with any and all applicable national and international laws and with any special restrictions regulating the utilization of the communication module in prescribed applications and environments. | TSW202 must be used in compliance with any and all applicable national and international laws and with any special restrictions regulating the utilization of the communication module in prescribed applications and environments. | ||
==CE Declaration of Conformity== | |||
{| class="wikitable" style="text-align:left;" | {| class="wikitable" style="text-align:left;" | ||
| Line 119: | Line 278: | ||
|} | |} | ||
== FCC == | |||
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: | This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: | ||
| Line 139: | Line 298: | ||
== ISED Canada == | |||
This device contains license-exempt transmitter(s)/receiver(s) that comply with Innovation, Science, and Economic Development Canada's license-exempt RSS(s). Operation is subject to the following two conditions: | This device contains license-exempt transmitter(s)/receiver(s) that comply with Innovation, Science, and Economic Development Canada's license-exempt RSS(s). Operation is subject to the following two conditions: | ||
| Line 150: | Line 309: | ||
== NOM == | |||
La operación de este equipo está sujeta a las siguientes dos condiciones: | La operación de este equipo está sujeta a las siguientes dos condiciones: | ||
| Line 169: | Line 328: | ||
[[Image:UKCA_LOGO.png|50px]] Hereby, TELTONIKA NETWORKS declares that the radio equipment type TSW202 is in compliance with Radio Equipment Regulations 2017. The full text of the UK declaration of conformity is available at the following internet address: https://wiki.teltonika-networks.com/view/TSW202_UKCA. | [[Image:UKCA_LOGO.png|50px]] Hereby, TELTONIKA NETWORKS declares that the radio equipment type TSW202 is in compliance with Radio Equipment Regulations 2017. The full text of the UK declaration of conformity is available at the following internet address: https://wiki.teltonika-networks.com/view/TSW202_UKCA. | ||
=== Operating conditions == | '''DNV-CG-0339 Statement''' | ||
When in use according to DNV-CG-0339 specification, the power supply must feature galvanic isolation. The device does not feature galvanic isolation. | |||
=Product Safety and Use= | |||
== Operating conditions == | |||
* Operating temperature: -40° to +75° Celsius | * Operating temperature: -40° to +75° Celsius | ||
* Humidity should be in the range of | * Humidity should be in the range of 5% to 95% (non-condensing). Only use the device in dry environments. | ||
* Out of direct sunlight | * Out of direct sunlight | ||
* Away from heat source, corrosive substances, salts, and flammable gases | * Away from heat source, corrosive substances, salts, and flammable gases | ||
| Line 178: | Line 342: | ||
'''Attention:''' operation outside the permissible range can considerably shorten the service life of the device. | '''Attention:''' operation outside the permissible range can considerably shorten the service life of the device. | ||
== Faulty and damaged products == | |||
* Do not attempt to disassemble the device or its accessories. | * Do not attempt to disassemble the device or its accessories. | ||
| Line 185: | Line 348: | ||
* If your device or its accessories have been submerged in water punctured or subjected to a severe fall, do not use until they have been checked at an authorized service center. | * If your device or its accessories have been submerged in water punctured or subjected to a severe fall, do not use until they have been checked at an authorized service center. | ||
== Electrical safety == | |||
* Only use approved accessories. | * Only use approved accessories. | ||
| Line 192: | Line 354: | ||
* It is recommended to ground devices with grounding terminals before connecting them to power. Failure to ground appropriately might result in a shock hazard. The cross-sectional area of the protective grounding conductor should be at least 1mm2. | * It is recommended to ground devices with grounding terminals before connecting them to power. Failure to ground appropriately might result in a shock hazard. The cross-sectional area of the protective grounding conductor should be at least 1mm2. | ||
== Product handling == | |||
* You alone are responsible for how you use your device and any consequences related to its use. | * You alone are responsible for how you use your device and any consequences related to its use. | ||
| Line 216: | Line 377: | ||
* Do not leave your device and its accessories within reach of small children or allow them to play with it. They could hurt themselves or others and could accidentally damage the device. Your device contains small parts with sharp edges that may cause an injury choking hazard. | * Do not leave your device and its accessories within reach of small children or allow them to play with it. They could hurt themselves or others and could accidentally damage the device. Your device contains small parts with sharp edges that may cause an injury choking hazard. | ||
* The device may become warm during regular use. | * The device may become warm during regular use. | ||