TSW202 Power Consumption: Difference between revisions

From Teltonika Networks Wiki
No edit summary
No edit summary
 
(One intermediate revision by one other user not shown)
Line 1: Line 1:
'''Averaged''' TSW202 power consumption values in different states of operation are represented in the table(s) below:
<table class="nd-othertables_3">
<table class="nd-othertables_3">
     <tr style="font-weight:bold">
     <tr style="font-weight:bold">

Latest revision as of 08:21, 12 November 2024

Main Page > TSW Switches > TSW202 > TSW202 Manual > TSW202 Power Consumption

Averaged TSW202 power consumption values in different states of operation are represented in the table(s) below:

Test type
Current (mA)
Power consumption (W)
Idle (12 V)
121
1.45
Idle (24 V)
66
1.58
Idle (54 V)
43
2.32
Idle (57 V)
42
2.39


Test type
Current (mA)
Power consumption (W)
8 LAN and 2 SFP devices connected, heavy data traffic1 (12 V)
388
4.66
8 LAN and 2 SFP devices connected, heavy data traffic1 (24 V)
195
4.68
8 LAN and 2 SFP devices connected, heavy data traffic1 (54 V)
103
5.56
8 LAN and 2 SFP devices connected, heavy data traffic1 (57 V)
99
5.64

1 - Data streams between devices were created using iPerf3.
Power consumption may differ due to testing environment and conditions.