TSF010 Power Consumption: Difference between revisions

From Teltonika Networks Wiki
No edit summary
No edit summary
 
(5 intermediate revisions by 2 users not shown)
Line 1: Line 1:
TSF010 power consumption values in different states of operation are represented in the table(s) below:<br>
'''Averaged''' TSF010 power consumption values in different states of operation are represented in the table(s) below:
 
<table class="nd-othertables_3">
<table class="nd-othertables_3">
     <tr style="font-weight:bold">
     <tr style="font-weight:bold">
Line 193: Line 194:
     </tr>
     </tr>
</table>
</table>
<table class="nd-othertables_3">
    <tr style="font-weight:bold">
        <th width=800>Test type</th>
      <th width=150><center>Current (mA)</center></th>
      <th width=170><center>Power consumption (W)</center></th>
    </tr>
    <tr>
        <td>4 PoE dummy loads connected (30 W each), 5 LAN devices connected + heavy data traffic<sup><small>1</small></sup> (54 V)</td>
      <td><center><b>2186</b></center></td>
      <td><center><b>118</b></center></td>
    </tr>
</table>


<small><sup><small>1</small></sup> - Data streams between devices were created using iPerf.</small> <br>
<small><sup><small>1</small></sup> - Data streams between devices were created using iPerf.</small> <br>
<small>Power consumption may differ due to connected devices, testing environment and conditions.</small>
<small>Power consumption may differ due to connected devices, testing environment and conditions.</small>
[[Category:TSF010_Manual]]

Latest revision as of 16:39, 11 November 2024

Main Page > TSF Switches > TSF010 > TSF010 Manual > TSF010 Power Consumption

Averaged TSF010 power consumption values in different states of operation are represented in the table(s) below:

Test type
Current (mA)
Power consumption (W)
Idle (9 V)
24
0.22
Idle (12 V)
19
0.23
Idle (24 V)
11
0.26
Idle (44 V)
11
0.48
Idle (50 V)
11
0.55
Idle (57 V)
11
0.63


Test type
Current (mA)
Power consumption (W)
Idle, 2 LAN device connected (9 V)
49
0.44
Idle, 2 LAN device connected (12 V)
38
0.46
Idle, 2 LAN device connected (24 V)
21
0.5
Idle, 2 LAN device connected (44 V)
17
0.75
Idle, 2 LAN device connected (50 V)
16
0.8
Idle, 2 LAN device connected (57 V)
15
0.86


Test type
Current (mA)
Power consumption (W)
2 LAN devices connected + heavy data traffic1 (9 V)
48
0.432
2 LAN devices connected + heavy data traffic1 (12 V)
37
0.44
2 LAN devices connected + heavy data traffic1 (24 V)
21
0.5
2 LAN devices connected + heavy data traffic1 (44 V)
18
0.79
2 LAN devices connected + heavy data traffic1 (50 V)
16
0.8
2 LAN devices connected + heavy data traffic1 (57 V)
15
0.86


Test type
Current (mA)
Power consumption (W)
Idle, 5 LAN device connected (9 V)
85
0.77
Idle, 5 LAN device connected (12 V)
66
0.79
Idle, 5 LAN device connected (24 V)
37
0.89
Idle, 5 LAN device connected (44 V)
26
1.14
Idle, 5 LAN device connected (50 V)
24
1.2
Idle, 5 LAN device connected (57 V)
23
1.31


Test type
Current (mA)
Power consumption (W)
5 LAN devices connected + heavy data traffic1 (9 V)
82
0.74
5 LAN devices connected + heavy data traffic1 (12 V)
64
0.77
5 LAN devices connected + heavy data traffic1 (24 V)
36
0.86
5 LAN devices connected + heavy data traffic1 (44 V)
26
1.14
5 LAN devices connected + heavy data traffic1 (50 V)
24
1.2
5 LAN devices connected + heavy data traffic1 (57 V)
22
1.25

1 - Data streams between devices were created using iPerf.
Power consumption may differ due to connected devices, testing environment and conditions.