The <b>Main</b> page is used to configure DLMS physical devices and Cosem Groups.
The <b>Main</b> page is used to configure DLMS physical devices and Cosem Groups.
===General status===
----
This section displays DLMS general status information.
[[File:Networking_rutos_manual_dlms_dlms_connections_status.png|border|class=tlt-border]]


Notice the Global section config. It is used to outright turn the service off or on if any active configurations are present.
Notice the Global section config. It is used to outright turn the service off or on if any active configurations are present.


[[File:Networking rutos manual dlms dlms physical devices global button v1.png|border|class=tlt-border]]
[[File:Networking rutos manual dlms dlms physical devices global button v2.png|border|class=tlt-border]]


Clicking the Cog icon opens a modal window. The global configuration slider can be set and it's state saved.
Clicking the Cog icon opens a modal window. The global configuration slider can be set and it's state saved.
Line 33: Line 40:
dependent features, parameters, functions and classes requesting data from the server (physical device). In this structure, communication protocol stack is independent of application layer so both devices may communicate different media. To add a new physical device, click the 'Add' button.
dependent features, parameters, functions and classes requesting data from the server (physical device). In this structure, communication protocol stack is independent of application layer so both devices may communicate different media. To add a new physical device, click the 'Add' button.


[[File:Networking_rutos_manual_dlms_dlms_physical_devices_add_button_v3.png|border|class=tlt-border]]
[[File:Networking_rutos_manual_dlms_dlms_physical_devices_add_button_v4.png|border|class=tlt-border]]


After clicking 'Add' you will be redirected to the newly added physical device's configuration page.
After clicking 'Add' you will be redirected to the newly added physical device's configuration page.
====DLMS Physical device configuration====
----
The <b>DLMS Physical device configuration</b> section is used to configure the parameters of server (physical device).


[[File:Networking_rutos_manual_dlms_dlms_physical_devices_configuration_v3.png|border|class=tlt-border]]
[[File:Networking_rutos_manual_dlms_dlms_physical_devices_configuration_v3.png|border|class=tlt-border]]
Line 152: Line 155:
To add a new cosem group, click the 'Add' button.
To add a new cosem group, click the 'Add' button.


[[File:Networking_rutos_manual_dlms_dlms_cosem_groups_add_button_v1.png|border|class=tlt-border]]
[[File:Networking_rutos_manual_dlms_dlms_cosem_groups_add_button_v3.png|border|class=tlt-border]]


After clicking 'Add' you will be redirected to the newly added cosem group's configuration page.
After clicking 'Add' you will be redirected to the newly added cosem group's configuration page.
====DLMS Cosem group configuration====
----
The <b>DLMS Cosem group configuration</b> section is used to configure the parameters of cosem groups.


[[File:Networking_rutos_manual_dlms_dlms_cosem_groups_configuration v2.png|border|class=tlt-border]]
[[File:Networking_rutos_manual_dlms_dlms_cosem_groups_configuration v2.png|border|class=tlt-border]]
Line 194: Line 193:
<b>Cosem value</b> is a specific value retrieved from a defined server (physical device). To add a new cosem value, click the 'Add' button.
<b>Cosem value</b> is a specific value retrieved from a defined server (physical device). To add a new cosem value, click the 'Add' button.


[[File:Networking_rutos_manual_dlms_dlms_cosem_value_add_button_v3.png|border|class=tlt-border]]
[[File:Networking_rutos_manual_dlms_dlms_cosem_value_add_button_v4.png|border|class=tlt-border]]


After clicking 'Add' you will be redirected to the newly added cosem value's configuration page.
After clicking 'Add' you will be redirected to the newly added cosem value's configuration page.


[[File:Networking_rutos_manual_dlms_dlms_cosem_value_configuration_v1.png|border|class=tlt-border]]
[[File:Networking_rutos_manual_dlms_dlms_cosem_value_configuration_v2.png|border|class=tlt-border]]


<table class="nd-mantable">
<table class="nd-mantable">
Line 226: Line 225:
         <td>OBIS code value, actions are not executed, only properties are read.</td>
         <td>OBIS code value, actions are not executed, only properties are read.</td>
     </tr>
     </tr>
        <tr>
    <tr>
         <td>COSEM class id</td>
         <td>COSEM class id</td>
         <td>DATA (ID: 1) {{!}} REGISTER (ID: 3) {{!}} EXTENDED REGISTER (ID: 4) {{!}} DEMAND REGISTER (ID: 5) {{!}} REGISTER ACTIVATION (ID: 6) {{!}} <span style="color:red">PROFILE GENERIC (ID: 7)</span> {{!}} CLOCK (ID: 8) {{!}} SCRIPT TABLE (ID: 9) {{!}} SPECIAL DAYS TABLE (ID: 11) {{!}} ASSOCIATION LOGICAL NAME (ID: 15) {{!}} SAP ASSIGNMENT (ID: 17) {{!}} IMAGE TRANSFER (ID: 18) {{!}} IEC LOCAL PORT SETUP (ID: 19) {{!}} ACTIVITY CALENDAR (ID: 20) {{!}} REGISTER MONITOR (ID: 21) {{!}} ACTION SCHEDULE (ID: 22) {{!}} IEC HDLC SETUP (ID: 23) {{!}} IEC TWISTED PAIR SETUP (ID: 24) {{!}} UTILITY TABLES (ID: 26) {{!}} MODEM CONFIGURATION (ID: 27) {{!}} AUTO ANSWER (ID: 28) {{!}} AUTO CONNECT (ID: 29) {{!}} PUSH SETUP (ID: 40) {{!}} TCP UDP SETUP (ID: 41) {{!}} IP4 SETUP (ID: 42) {{!}} MAC ADDRESS SETUP (ID: 43) {{!}} GPRS SETUP (ID: 45) {{!}} GSM DIAGNOSTIC (ID: 47) {{!}} IP6 SETUP (ID: 48) {{!}} COMPACT DATA (ID: 62) {{!}} SECURITY SETUP (ID: 64) {{!}} ARBITRATOR (ID: 68) {{!}} DISCONNECT CONTROL (ID: 70) {{!}} LIMITER (ID: 71); default: <b>DATA (ID: 1)</b></td>
         <td>DATA (ID: 1) {{!}} REGISTER (ID: 3) {{!}} EXTENDED REGISTER (ID: 4) {{!}} DEMAND REGISTER (ID: 5) {{!}} REGISTER ACTIVATION (ID: 6) {{!}} <span style="color:red">PROFILE GENERIC (ID: 7)</span> {{!}} CLOCK (ID: 8) {{!}} SCRIPT TABLE (ID: 9) {{!}} SPECIAL DAYS TABLE (ID: 11) {{!}} ASSOCIATION LOGICAL NAME (ID: 15) {{!}} SAP ASSIGNMENT (ID: 17) {{!}} IMAGE TRANSFER (ID: 18) {{!}} IEC LOCAL PORT SETUP (ID: 19) {{!}} ACTIVITY CALENDAR (ID: 20) {{!}} REGISTER MONITOR (ID: 21) {{!}} ACTION SCHEDULE (ID: 22) {{!}} IEC HDLC SETUP (ID: 23) {{!}} IEC TWISTED PAIR SETUP (ID: 24) {{!}} UTILITY TABLES (ID: 26) {{!}} MODEM CONFIGURATION (ID: 27) {{!}} AUTO ANSWER (ID: 28) {{!}} AUTO CONNECT (ID: 29) {{!}} PUSH SETUP (ID: 40) {{!}} TCP UDP SETUP (ID: 41) {{!}} IP4 SETUP (ID: 42) {{!}} MAC ADDRESS SETUP (ID: 43) {{!}} GPRS SETUP (ID: 45) {{!}} GSM DIAGNOSTIC (ID: 47) {{!}} IP6 SETUP (ID: 48) {{!}} COMPACT DATA (ID: 62) {{!}} SECURITY SETUP (ID: 64) {{!}} ARBITRATOR (ID: 68) {{!}} DISCONNECT CONTROL (ID: 70) {{!}} LIMITER (ID: 71); default: <b>DATA (ID: 1)</b></td>
         <td>Object type for OBIS code.</td>
         <td>Object type for OBIS code.</td>
    </tr>
    <tr>
        <td>Atributes</td>
        <td>list; default: <b>all</b></td>
        <td>Available attributes for the selected COSEM class (check it [https://www.gurux.fi/Gurux.DLMS.Objects here]).</td>
     </tr>
     </tr>
     <tr>
     <tr>
Line 256: Line 260:
To add a new connection, click the 'Add' button.
To add a new connection, click the 'Add' button.


[[File:Networking_rutos_manual_dlms_dlms_connections_add_button_v1.png|border|class=tlt-border]]
[[File:Networking_rutos_manual_dlms_dlms_connections_add_button_v2.png|border|class=tlt-border]]


After clicking 'Add' you will be redirected to the newly added connection's configuration page.
After clicking 'Add' you will be redirected to the newly added connection's configuration page.
====DLMS Connection configuration====
----
The <b>DLMS Connection configuration</b> section is used to configure the parameters of connections.


[[File:Networking_rutos_manual_dlms_dlms_connections_configuration_v1.png|border|class=tlt-border]]
[[File:Networking_rutos_manual_dlms_dlms_connections_configuration_v1.png|border|class=tlt-border]]

Latest revision as of 09:30, 27 November 2024

The information in this page is updated in accordance with firmware version .

Summary

The DLMS / COSEM standard suite (IEC 62056 / EN 13757- 1) is the most widely accepted international utility meter data exchange standard. DLMS is the application layer protocol that transforms the data into messages and COSEM describes the general object model and can be used for all kinds of presentations.


This manual page provides an overview of the DLMS functionality in {{{name}}} devices.

Note: DLMS is additional software that can be installed from the System → [[{{{name}}} Package Manager|Package Manager]] page. Note: The count of DLMS connections is limited to 30, physical devices - up to 30, space groups - up to 10, cosem objects - up to 20 in each group.

Main

The Main page is used to configure DLMS physical devices and Cosem Groups.

General status


This section displays DLMS general status information.

Notice the Global section config. It is used to outright turn the service off or on if any active configurations are present.

Clicking the Cog icon opens a modal window. The global configuration slider can be set and it's state saved.

DLMS Physical devices


Interoperable devices in DLMS categorize as server (physical device) and client. Data collection device act as a client that supports system dependent features, parameters, functions and classes requesting data from the server (physical device). In this structure, communication protocol stack is independent of application layer so both devices may communicate different media. To add a new physical device, click the 'Add' button.

After clicking 'Add' you will be redirected to the newly added physical device's configuration page.

Field Value Description
Enable off | on; default: off Enables specific physical device configuration.
Connection empty ; default: none DLMS connection.
Name string; default: none Physical device name.
Server address type Default | Serial number; default: Default Select 'Default' for server address or 'Serial Number' for addressing by a specific serial number.
Server address integer [0..255]; default: 1 DLMS device server address.
Serial number unsigned integer; default: 1 DLMS device serial number. Uses formula 'SN % 10000 + 1000'.
Logic server address integer [0..255]; default: 0 DLMS device logical server address.
Client address integer [0..255]; default: 16 DLMS device client address.
Access security none | Low | High | High MD5 | High SHA1 | High GMAC | HIGH SHA256; default: none DLMS device authentication type.
Password string; default: none DLMS device password if authentication is used.
Interface type HDLC | WRAPPER; default: HDLC DLMS device interface type.
Transport security none | Authentication | Encryption | Authentication encryption; default: none DLMS device message encryption.
Authentication/Encryption/Authentication encryption: Invocation counter OBIS code string; default: none DLMS device invocation counter OBIS code.
Authentication/Authentication encryption: Authentication key string (Length of the value must be 32); default: none DLMS device authentication key.
Encryption/Authentication encryption: Block cipher key string (Length of the value must be 32); default: none DLMS device block cipher key.
Encryption/Authentication encryption: Dedicated key string (Length of the value must be 32); default: none DLMS device dedicated key.
Logical name referencing on | off; default: on DLMS devices use Logical Names to reference and access specific data objects or attributes during communication. For example, when requesting data from a device, you might reference a specific Logical Name to retrieve the information.
Test -(interactive button) Test device configuration.


Scan device parameters


After successfully adding the 'DLMS physical devices' configuration, and if the DLMS server is available, you can initiate a Device Parameters scan, which will write the parameters locally next to the cosem value configuration.

DLMS Cosem groups


To add a new cosem group, click the 'Add' button.

After clicking 'Add' you will be redirected to the newly added cosem group's configuration page.

Field Value Description
Enable off | on; default: off Enables Cosem group.
Name string; default: none OBIS code group name.
Interval integer [1..4294967295]; default: 1 Interval for OBIS code reading (in seconds).
Test -(interactive button) Test cosem group.

DLMS Cosem value


Cosem value is a specific value retrieved from a defined server (physical device). To add a new cosem value, click the 'Add' button.

After clicking 'Add' you will be redirected to the newly added cosem value's configuration page.

Field Value Description
Enable off | on; default: off Enables Cosem state.
Name string; default: none COSEM option name.
Physical device selection; default: none Physical device to read from.
OBIS code string; default: none OBIS code value, actions are not executed, only properties are read.
COSEM class id DATA (ID: 1) | REGISTER (ID: 3) | EXTENDED REGISTER (ID: 4) | DEMAND REGISTER (ID: 5) | REGISTER ACTIVATION (ID: 6) | PROFILE GENERIC (ID: 7) | CLOCK (ID: 8) | SCRIPT TABLE (ID: 9) | SPECIAL DAYS TABLE (ID: 11) | ASSOCIATION LOGICAL NAME (ID: 15) | SAP ASSIGNMENT (ID: 17) | IMAGE TRANSFER (ID: 18) | IEC LOCAL PORT SETUP (ID: 19) | ACTIVITY CALENDAR (ID: 20) | REGISTER MONITOR (ID: 21) | ACTION SCHEDULE (ID: 22) | IEC HDLC SETUP (ID: 23) | IEC TWISTED PAIR SETUP (ID: 24) | UTILITY TABLES (ID: 26) | MODEM CONFIGURATION (ID: 27) | AUTO ANSWER (ID: 28) | AUTO CONNECT (ID: 29) | PUSH SETUP (ID: 40) | TCP UDP SETUP (ID: 41) | IP4 SETUP (ID: 42) | MAC ADDRESS SETUP (ID: 43) | GPRS SETUP (ID: 45) | GSM DIAGNOSTIC (ID: 47) | IP6 SETUP (ID: 48) | COMPACT DATA (ID: 62) | SECURITY SETUP (ID: 64) | ARBITRATOR (ID: 68) | DISCONNECT CONTROL (ID: 70) | LIMITER (ID: 71); default: DATA (ID: 1) Object type for OBIS code.
Atributes list; default: all Available attributes for the selected COSEM class (check it here).
Entries interger [1..32767]; default: none How many data objects to read.
Device Parameters

Parameters that are found after scan has finished.

Connections

The Connections page is used to configure DLMS connections. You can use either TCP or serial (depending on the router) connection to establish a connection between the physical device and the router.

General status


This section displays DLMS general status information.

DLMS Connections


To add a new connection, click the 'Add' button.

After clicking 'Add' you will be redirected to the newly added connection's configuration page.

Field Value Description
Enable off | on; default: off Enables Cosem state.
Name string; default: previously added connection name Name of DLMS connection configuration.
Connection type TCP ; default: TCP DLMS connection type.
IP address ip; default: none DLMS device IP address for TCP connection.
Port integer [1..65535]; default: none DLMS device IP port for TCP connection.
Persistent off | on; default: off Open TCP connection once and reuse it between requests.

[[Category:{{{name}}} Services section]]