Template:Networking rutos manual input output pinout: Difference between revisions

From Teltonika Networks Wiki
No edit summary
No edit summary
 
Line 93: Line 93:
     <li><b>A</b> and <b>⏚</b><sub>1</sub> - ADC input. Analog voltage range: 0-24 V. The input can be configured for 4-20 mA sensor protocol as current measurement (ACL).<span class="asterisk">*</span></li>
     <li><b>A</b> and <b>⏚</b><sub>1</sub> - ADC input. Analog voltage range: 0-24 V. The input can be configured for 4-20 mA sensor protocol as current measurement (ACL).<span class="asterisk">*</span></li>
     <li><b>⏚</b><sub>1</sub> - GND for <b>DI</b><sub>1</sub> and <b>A</b>.</li>
     <li><b>⏚</b><sub>1</sub> - GND for <b>DI</b><sub>1</sub> and <b>A</b>.</li>
     <li><b>⏚</b><sub>2</sub> - GND for <b>DI</b><sub>2</sub>.
     <li><b>⏚</b><sub>2</sub> - GND for <b>DI</b><sub>2</sub>.</li>
     <li><b>⏚</b><sub>3</sub> - GND for <b>DO</b> pins.
     <li><b>⏚</b><sub>3</sub> - GND for <b>DO</b> pins.</li>
     <li><b>''Note:''</b> input circuit components have tolerance of +-1%.</li>
     <li><b>''Note:''</b> input circuit components have tolerance of +-1%.</li>
</ul>
</ul>

Latest revision as of 09:32, 2 December 2024

Power Socket Pinout


[[File:Networking_rutos_manual_input_output_power_socket_pinout_configurableio_{{{configurableio}}}.png]]

  • Power: {{{input_volts}}} VDC positive (+).
  • Ground: negative/ground (-).
  • Input: digital non-isolated input.
    • logical low level: 0 - 5 V;
    • logical high level: 8 - 30 V.
  • Output: digital open collector (OC) output; 30 V, 300 mA.