Modbus TCP Server Send SMS example: Difference between revisions

From Teltonika Networks Wiki
(Created page with "==Introduction== <span style="color: red;">The information on this page is updated in accordance with firmware version <span style="color: #0054A6;"><b>00.07.03.2</b></span>....")
 
No edit summary
Line 8: Line 8:


If you're having trouble finding this page or some of the parameters described here on your device's WebUI, you should '''turn on "Advanced WebUI" mode'''. You can do that by clicking the "Basic" button under "Mode", which is located at the top-right corner of the WebUI.
If you're having trouble finding this page or some of the parameters described here on your device's WebUI, you should '''turn on "Advanced WebUI" mode'''. You can do that by clicking the "Basic" button under "Mode", which is located at the top-right corner of the WebUI.
[[File:Networking rutx manual webui basic advanced mode v1.gif|border|class=tlt-border]]
== Prerequisites ==
* At least one TRB/RUT device with the SIM card, for this example we will be using one device
* One end device (PC, Laptop, Tablet, Smartphone) to configure the router
* One Mobile Phone in order to test the configuration
== Configuring Modbus TCP Slave and Modbus TCP Master ==
Firstly, we will configure '''Modbus TCP Slave''' on the router and then on the same device we will configure '''Modbus TCP Master''' in order to send Modbus requests to the same device.

Revision as of 14:28, 19 January 2023

Main Page > General Information > Configuration Examples > Modbus > Modbus TCP Server Send SMS example

Introduction

The information on this page is updated in accordance with firmware version 00.07.03.2.

Modbus is a serial communications protocol. Simple and robust, it has become a de facto standard communication protocol and is now a commonly available means of connecting industrial electronic devices.

In this configuration example, we will configure Modbus TCP Slave and Modbus TCP Master. We will send a Set Parameters request from Modbus TCP Master to Modbus TCP Slave, which will send an SMS message provided in the Modbus TCP Master Set PArameter request.

If you're having trouble finding this page or some of the parameters described here on your device's WebUI, you should turn on "Advanced WebUI" mode. You can do that by clicking the "Basic" button under "Mode", which is located at the top-right corner of the WebUI.

Prerequisites

  • At least one TRB/RUT device with the SIM card, for this example we will be using one device
  • One end device (PC, Laptop, Tablet, Smartphone) to configure the router
  • One Mobile Phone in order to test the configuration

Configuring Modbus TCP Slave and Modbus TCP Master

Firstly, we will configure Modbus TCP Slave on the router and then on the same device we will configure Modbus TCP Master in order to send Modbus requests to the same device.