TAP100 Power Consumption: Difference between revisions

From Teltonika Networks Wiki
(Undo revision 105252 by Vainius.l (talk))
Tag: Undo
m (Vainius.l moved page Draft:TAP100 Power Consumption to TAP100 Power Consumption without leaving a redirect)
(No difference)

Revision as of 13:27, 24 May 2023

Main Page > TAP Access Points > TAP100 > TAP100 Manual > TAP100 Power Consumption

TAP100 power consumption values in different states of operation are represented in the table(s) below:

Test type
Current (mA)
Power consumption (W)
Idle (44 V)
27
1.17
Idle (50 V)
24
1.20
Idle (57 V)
21
1.23


Test type
Current (mA)
Power consumption (W)
Data transfer via WiFi (one client) (44 V)
32
1.41
Data transfer via WiFi (one client) (50 V)
29
1.44
Data transfer via WiFi (one client) (57 V)
26
1.48


Test type
Current (mA)
Power consumption (W)
1 LAN devices connected 1 + data transfer via WiFi (one client) + high CPU load 2 (44 V)
33
1.43
1 LAN devices connected 1 + data transfer via WiFi (one client) + high CPU load 2 (50 V)
29
1.46
1 LAN devices connected 1 + data transfer via WiFi (one client) + high CPU load 2 (57 V)
26
1.52


1 - Data streams between TAP100 and other connected LAN devices created using iPerf.
2 - Load created using md5sum (calculation and verification of 128-bit MD5 hashes).
Power consumption may differ due to mobile data transmission speed, testing environment and conditions.