RUT140 Power Consumption: Difference between revisions
Appearance
Created blank page |
No edit summary |
||
| Line 1: | Line 1: | ||
RUT140 power consumption values in different states of operation are represented in the table(s) below:<br><br> | |||
<table class="nd-othertables_3"> | |||
<tr style="font-weight:bold"> | |||
<th width=800>Test type</th> | |||
<th width=150><center>Current (mA)</center></th> | |||
<th width=170><center>Power consumption (W)</center></th> | |||
</tr> | |||
<tr> | |||
<td>Idle (9 V)</td> | |||
<td><center><b>88</b></center></td> | |||
<td><center><b>0.79</b></center></td> | |||
</tr> | |||
<tr> | |||
<td>Idle (12 V)</td> | |||
<td><center><b>67</b></center></td> | |||
<td><center><b>0.80</b></center></td> | |||
</tr> | |||
<tr> | |||
<td>Idle (24 V)</td> | |||
<td><center><b>40</b></center></td> | |||
<td><center><b>0.96</b></center></td> | |||
</tr> | |||
</table> | |||
<table class="nd-othertables_3"> | |||
<tr style="font-weight:bold"> | |||
<th width=800>Test type</th> | |||
<th width=150><center>Current (mA)</center></th> | |||
<th width=170><center>Power consumption (W)</center></th> | |||
</tr> | |||
<tr> | |||
<td>1 LAN devices connected <sup><small>1</small></sup> (9 V)</td> | |||
<td><center><b>113</b></center></td> | |||
<td><center><b>1.02</b></center></td> | |||
</tr> | |||
<tr> | |||
<td>1 LAN devices connected <sup><small>1</small></sup> (12 V)</td> | |||
<td><center><b>87</b></center></td> | |||
<td><center><b>1.04</b></center></td> | |||
</tr> | |||
<tr> | |||
<td>1 LAN devices connected <sup><small>1</small></sup> (24 V)</td> | |||
<td><center><b>49</b></center></td> | |||
<td><center><b>1.18</b></center></td> | |||
</tr> | |||
</table> | |||
<table class="nd-othertables_3"> | |||
<tr style="font-weight:bold"> | |||
<th width=800>Test type</th> | |||
<th width=150><center>Current (mA)</center></th> | |||
<th width=170><center>Power consumption (W)</center></th> | |||
</tr> | |||
<tr> | |||
<td>2 LAN devices connected <sup><small>1</small></sup> + high CPU load <sup><small>2</small></sup> + data transfer via WiFi (9 V)</td> | |||
<td><center><b>133</b></center></td> | |||
<td><center><b>1.2</b></center></td> | |||
</tr> | |||
<tr> | |||
<td>2 LAN devices connected <sup><small>1</small></sup> + high CPU load <sup><small>2</small></sup> + data transfer via WiFi (12 V)</td> | |||
<td><center><b>103</b></center></td> | |||
<td><center><b>1.27</b></center></td> | |||
</tr> | |||
<tr> | |||
<td>2 LAN devices connected <sup><small>1</small></sup> + high CPU load <sup><small>2</small></sup> + data transfer via WiFi (24 V)</td> | |||
<td><center><b>58</b></center></td> | |||
<td><center><b>1.39</b></center></td> | |||
</tr> | |||
</table> | |||
<small><sup><small>1</small></sup> - Data streams between RUT140 and other connected LAN devices created using iPerf.</small> <br> | |||
<small><sup><small>2</small></sup> - Load created using ''md5sum'' (calculation and verification of 128-bit MD5 hashes). </small> <br> | |||
<small>Power consumption may differ due to mobile data transmission speed, testing environment and conditions.</small> | |||
Revision as of 11:30, 4 April 2024
Main Page > RUT Routers > RUT140 > RUT140 Manual > RUT140 Power ConsumptionRUT140 power consumption values in different states of operation are represented in the table(s) below:
| Test type | ||
|---|---|---|
| Idle (9 V) | ||
| Idle (12 V) | ||
| Idle (24 V) |
| Test type | ||
|---|---|---|
| 1 LAN devices connected 1 (9 V) | ||
| 1 LAN devices connected 1 (12 V) | ||
| 1 LAN devices connected 1 (24 V) |
| Test type | ||
|---|---|---|
| 2 LAN devices connected 1 + high CPU load 2 + data transfer via WiFi (9 V) | ||
| 2 LAN devices connected 1 + high CPU load 2 + data transfer via WiFi (12 V) | ||
| 2 LAN devices connected 1 + high CPU load 2 + data transfer via WiFi (24 V) |
1 - Data streams between RUT140 and other connected LAN devices created using iPerf.
2 - Load created using md5sum (calculation and verification of 128-bit MD5 hashes).
Power consumption may differ due to mobile data transmission speed, testing environment and conditions.