TSW114 Power Consumption: Difference between revisions

From Teltonika Networks Wiki
No edit summary
No edit summary
Line 1: Line 1:
TSW114 power consumption values in different states of operation are represented in the table(s) below:<br><br>
'''Averaged''' TSW114 power consumption values in different states of operation are represented in the table(s) below:<br><br>
<table class="nd-othertables_3">
<table class="nd-othertables_3">
     <tr style="font-weight:bold">
     <tr style="font-weight:bold">

Revision as of 09:52, 16 August 2024

Main Page > TSW Switches > TSW114 > TSW114 Manual > TSW114 Power Consumption

Averaged TSW114 power consumption values in different states of operation are represented in the table(s) below:

Test type
Current (mA)
Power consumption (W)
Idle (9 V)
26
0.24
Idle (12 V)
21
0.25
Idle (24 V)
12
0.30


Test type
Current (mA)
Power consumption (W)
2 LAN devices connected + heavy data traffic1 (9 V)
99
0.86
2 LAN devices connected + heavy data traffic1 (12 V)
74
0.89
2 LAN devices connected + heavy data traffic1 (24 V)
43
1.03


Test type
Current (mA)
Power consumption (W)
5 LAN devices connected + heavy data traffic1 (9 V)
204
1.84
5 LAN devices connected + heavy data traffic1 (12 V)
154
1.85
5 LAN devices connected + heavy data traffic1 (24 V)
86
2.07


1 - Data streams between devices were created using iPerf.
Power consumption may differ due to connected devices, testing environment and conditions.