RUT140 Power Consumption: Difference between revisions

From Teltonika Networks Wiki
m (Vainius.l moved page Draft:RUT140 Power Consumption to RUT140 Power Consumption without leaving a redirect)
No edit summary
Line 75: Line 75:
<small><sup><small>2</small></sup> - Load created using ''md5sum'' (calculation and verification of 128-bit MD5 hashes). </small> <br>
<small><sup><small>2</small></sup> - Load created using ''md5sum'' (calculation and verification of 128-bit MD5 hashes). </small> <br>
<small>Power consumption may differ due to mobile data transmission speed, testing environment and conditions.</small>
<small>Power consumption may differ due to mobile data transmission speed, testing environment and conditions.</small>
[[Category:RUT140 Manual]]

Revision as of 12:21, 9 April 2024

Main Page > RUT Routers > RUT140 > RUT140 Manual > RUT140 Power Consumption

RUT140 power consumption values in different states of operation are represented in the table(s) below:

Test type
Current (mA)
Power consumption (W)
Idle (9 V)
88
0.79
Idle (12 V)
67
0.80
Idle (24 V)
40
0.96


Test type
Current (mA)
Power consumption (W)
1 LAN devices connected 1 (9 V)
113
1.02
1 LAN devices connected 1 (12 V)
87
1.04
1 LAN devices connected 1 (24 V)
49
1.18


Test type
Current (mA)
Power consumption (W)
2 LAN devices connected 1 + high CPU load 2 + data transfer via WiFi (9 V)
133
1.2
2 LAN devices connected 1 + high CPU load 2 + data transfer via WiFi (12 V)
103
1.27
2 LAN devices connected 1 + high CPU load 2 + data transfer via WiFi (24 V)
58
1.39


1 - Data streams between RUT140 and other connected LAN devices created using iPerf.
2 - Load created using md5sum (calculation and verification of 128-bit MD5 hashes).
Power consumption may differ due to mobile data transmission speed, testing environment and conditions.