Template:PCN RS485 RE-DE TRB 2024 05: Difference between revisions
No edit summary |
|||
Line 1: | Line 1: | ||
==2024.05.18: Hardware changes== | ==2024.05.18: Hardware changes== | ||
Starting from Q3 2024, all {{{name}}} devices will be manufactured with modifications to the RS485 RE/DE management hardware | Starting from Q3 2024, all {{{name}}} devices will be manufactured with modifications to the RS485 RE/DE management hardware. | ||
{| class="wikitable" | {| class="wikitable" | ||
Line 11: | Line 11: | ||
{| class="wikitable" | {| class="wikitable" | ||
|+ | |+ | ||
! colspan=" | ! colspan="2" style="text-align: left; background: #eeece1;" |Change description | ||
|- | |- | ||
| style="text-align: left; background: white;" |Change type | | style="text-align: left; background: white;" |Change type | ||
| style="text-align: left; background: white; | | style="text-align: left; background: white;" |Hardware change | ||
|- | |- | ||
| style="width: 221px; text-align: left; background: white; | | style="width: 221px; text-align: left; background: white;" | Detailed description | ||
| style="width: 908px; text-align: left; background: white; | | style="width: 908px; text-align: left; background: white;" | In the latest hardware revision of the {{{name}}} device, changes have been made to enhance the management of RS485 signalling. {{{name}}} will require firmware version TRB1_R_00.07.06 or newer to ensure compatibility with the hardware changes and to maintain full functionality. '''Important Note:''' Due to hardware changes, downgrading to firmware versions below, RutOS TRB1_R_00.07.06 is no longer supported.<br> | ||
|- | |- | ||
| style="text-align: left; background: white;" | Change reasons | | style="text-align: left; background: white;" | Change reasons | ||
| style="text-align: left; background: white; | | style="text-align: left; background: white;" | Improved Hardware Compatibility | ||
|- | |- | ||
|} | |} | ||
Line 64: | Line 49: | ||
* Devices with the new hardware changes will not support firmware versions below TRB1_R_00.07.06. | * Devices with the new hardware changes will not support firmware versions below TRB1_R_00.07.06. | ||
* Custom firmware built on previous SDK versions will also not be supported. | * Custom firmware built on previous SDK versions will also not be supported. | ||
'''Please note''': this product change notification does not affect any previous {{{name}}} devices, except new {{{name}}} devices | '''Please note''': this product change notification does not affect any previous {{{name}}} devices, except new {{{name}}} devices. | ||
|- | |- |
Revision as of 13:08, 24 May 2024
2024.05.18: Hardware changes
Starting from Q3 2024, all {{{name}}} devices will be manufactured with modifications to the RS485 RE/DE management hardware.
PCN Number: PCN_RS485_{{{name}}}_2024_05_18_EN |
Change description | |
---|---|
Change type | Hardware change |
Detailed description | In the latest hardware revision of the {{{name}}} device, changes have been made to enhance the management of RS485 signalling. {{{name}}} will require firmware version TRB1_R_00.07.06 or newer to ensure compatibility with the hardware changes and to maintain full functionality. Important Note: Due to hardware changes, downgrading to firmware versions below, RutOS TRB1_R_00.07.06 is no longer supported. |
Change reasons | Improved Hardware Compatibility |
Affected products information | ||
---|---|---|
Model | Affected order codes | Order code changes |
{{{name}}} | {{{name}}} ****** | No changes |
Upcoming change date | 2024 Q3 |
Change impact | ||
---|---|---|
Risk assessment |
Please note: this product change notification does not affect any previous {{{name}}} devices, except new {{{name}}} devices. | |
Suggested implementation plan |
Information included in this PCN will help adapt to the upcoming changes. For more detailed information, please contact your sales representative. |
Acknowledgement of PCN receipt | ||
---|---|---|
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above. |
To download the pdf version of this notification, [[Media:{{{name}}}Missing.pdf|click here]].