Jump to content

BAT120 LEDs: Difference between revisions

From Teltonika Networks Wiki
No edit summary
No edit summary
Line 7: Line 7:
The <b>IN PWR LED</b> is the left-most located LED on the front panel:
The <b>IN PWR LED</b> is the left-most located LED on the front panel:


[[File:Network_bat_manual_bat120_pwrin_led_v1.png|400px]]
[[File:Networking_bat120_manual_leds_power_in_led.png|400px]]


<table class="nd-othertables_2">
<table class="nd-othertables_2">
Line 21: Line 21:
     <td>LED turned ON red</td>
     <td>LED turned ON red</td>
     <td>PSU connected to IN PWR socket, charge failure /Vin too low</td>
     <td>PSU connected to IN PWR socket, charge failure /Vin too low</td>
    </tr>
</table>
</table>


Line 27: Line 28:
The <b>OUT PWR LED</b> is the second from the left LED located on the front panel:
The <b>OUT PWR LED</b> is the second from the left LED located on the front panel:


[[File:Network_bat_manual_bat120_pwrout_led_v1.png|400px]]
[[File:Networking_bat120_manual_leds_power_out_led.png|400px]]
<br>
<br>
'''''Note:''' OUT PWR LED will illuminate green when connected load is greater than 0.5W. If the power consumed by an external device is less than 0.5W, it will still be powered, but OUT PWR LED will stay off.''
'''''Note:''' OUT PWR LED will illuminate green when connected load is greater than 0.5W. If the power consumed by an external device is less than 0.5W, it will still be powered, but OUT PWR LED will stay off.''
Line 50: Line 51:
The <b>Power LEDs</b> are located in the middle of the front panel:
The <b>Power LEDs</b> are located in the middle of the front panel:


[[File:Network_bat_manual_bat120_pwr_led_v1.png|400px]]
[[File:Networking_bat120_manual_leds_power_led.png|400px]]


<table class="nd-othertables_2">
<table class="nd-othertables_2">

Revision as of 14:56, 29 January 2025

Main Page > BAT Uninterruptible Power Supplies > BAT120 > BAT120 Manual > BAT120 LEDs

This wiki page contains information about BAT120 LEDs and their actions.

Power IN LED

The IN PWR LED is the left-most located LED on the front panel:

Action Description
LED turned ON green PSU connected to IN PWR socket
LED turned ON red PSU connected to IN PWR socket, charge failure /Vin too low

Power OUT LED

The OUT PWR LED is the second from the left LED located on the front panel:


Note: OUT PWR LED will illuminate green when connected load is greater than 0.5W. If the power consumed by an external device is less than 0.5W, it will still be powered, but OUT PWR LED will stay off.

Action Description
LED turned ON green OUT PWR socket connected to the device and external device is being powered
LED turned ON red If the OUTPUT is shorted (requiring a reset) or the BAT120 has overheated (no reset needed), the OUT PWR LED will turn red, signifying an issue that needs attention.

Power LEDs

The Power LEDs are located in the middle of the front panel:

Action Description
LED turned ON Shows BAT120 state of charge. Each LED equals to 25% of SOC.

Combined LED states

Some of the states are shown with multiple LEDs:

Action Description
Power LEDs blink every 5 seconds BAT120 is charging.