Template:Networking rutos manual data to server: Difference between revisions
No edit summary |
No edit summary |
||
Line 7: | Line 7: | ||
==Summary== | ==Summary== | ||
Data to Server | The <b>Data to Server</b> feature provides you with the possibility to set up senders that transfer data collected from Modbus slaves {{#ifeq:{{{bluetooth}}}|1|or Bluetooth devices|}} to remote servers. | ||
{{Template:Networking_rutos_manual_basic_advanced_webui_disclaimer | {{Template:Networking_rutos_manual_basic_advanced_webui_disclaimer | ||
Line 13: | Line 13: | ||
}} | }} | ||
==Data | ==Data Senders== | ||
To add a new data sender, click the | The <b>To add a new data sender, click the 'Add' button: | ||
[[File: | [[File:Networking_rutos_manual_data_to_server_data_senders_edit_button.png|border|class=tlt-border]] | ||
=== | ====== | ||
---- | ---- | ||
Line 27: | Line 27: | ||
====General==== | ====General==== | ||
<table class="nd-mantable"> | <table class="nd-mantable"> | ||
<tr> | <tr> | ||
Line 35: | Line 36: | ||
<tr> | <tr> | ||
<td>Enabled</td> | <td>Enabled</td> | ||
<td>off | <td>off | on; default: <b>off</b></td> | ||
<td> | <td>Turns the data sender on or off.</td> | ||
</tr> | </tr> | ||
<tr> | <tr> | ||
Line 42: | Line 43: | ||
<td>string; default: <b>none</b></td> | <td>string; default: <b>none</b></td> | ||
<td>Name of the data sender. Used for easier data senders management purposes only (optional).</td> | <td>Name of the data sender. Used for easier data senders management purposes only (optional).</td> | ||
</tr> | </tr>{{#ifeq: {{{wifi}}} | 1 | | ||
<tr> | <tr> | ||
<td>Data source</td> | <td>Data source</td> | ||
<td>Modbus data {{ | <td>Modbus data {{#ifeq:{{{bluetooth}}}|1|<nowiki>|</nowiki> Bluetooth data |}}{{#ifeq:{{{wifi}}}|1|<nowiki>|</nowiki> WiFi scanner data|}}; default: <b>Modbus data</b></td> | ||
<td>Source of the data to be sent to server.</td> | <td>Source of the data to be sent to server.</td> | ||
</tr> | </tr>|}} | ||
<tr> | <tr> | ||
<td>Protocol</td> | <td>Protocol</td> | ||
<td>HTTP(S) | <td>HTTP(S) | MQTT | Kinesis; default: <b>HTTP(S)</b></td> | ||
<td>Protocol used for sending the data to server.</td> | <td>Protocol used for sending the data to server.</td> | ||
</tr> | </tr> | ||
<tr> | <tr> | ||
<td>JSON format</td> | <td>JSON format</td> | ||
<td>string; default: | <td>string; default: </b>{"TS": "%t", "D": "%d", "data": %a}</b></td> | ||
<td>Arranges the format of the sent JSON segment.</td> | |||
<td> | |||
</tr> | </tr> | ||
<tr> | <tr> | ||
<td>Segment count</td> | <td>Segment count</td> | ||
<td>integer [1..10]; default: | <td>integer [1..10]; default: <b>1</b></td> | ||
<td>Max segment count in one JSON string sent to server.</td> | <td>Max segment count in one JSON string sent to server.</td> | ||
</tr> | |||
<tr> | |||
<td>Send as object</td> | |||
<td>off | on; default: <b>off</b></td> | |||
<td>When turned on, sends JSON segment as object and not as an array element.</td> | |||
</tr> | </tr> | ||
<tr> | <tr> | ||
Line 97: | Line 76: | ||
<tr> | <tr> | ||
<td>Period</td> | <td>Period</td> | ||
<td>integer [1..86400]; default: | <td>integer [1..86400]; default: <b>60</b></td> | ||
<td> | <td>Data sending frequency (in seconds).</td> | ||
</tr> | </tr> | ||
<tr> | <tr> | ||
<td>Data filtering</td> | <td>Data filtering</td> | ||
<td>All data | <td>All data | <span style="color:darkred">By slave ID</span> | <span style="color:blue">By slave IP</span>; default: <b>All data</b></td> | ||
<td>Choose which data this sender will send to server.</td> | <td>Choose which data this sender will send to server.</td> | ||
</tr> | </tr> | ||
<tr> | <tr> | ||
<td><span style="color:darkred">By slave ID:</span> Slave ID</td> | <td><span style="color:darkred">By slave ID:</span> Slave ID</td> | ||
<td>integer [1..255]; default: | <td>integer [1..255]; default: <b>none</b></td> | ||
<td> | <td>ID of the Modbus slave whose collected data will be sent to server.</td> | ||
</tr> | </tr> | ||
<tr> | <tr> | ||
<td><span style="color:blue">By slave IP:</span> Slave IP</td> | <td><span style="color:blue">By slave IP:</span> Slave IP</td> | ||
<td>ip; default: | <td>ip; default: </b>none</b></td> | ||
<td> | <td>IP address of the Modbus slave whose collected data will be sent to server (for Modbus TCP slaves).</td> | ||
</tr> | </tr> | ||
<tr> | <tr> | ||
<td>Retry on fail</td> | <td>Retry on fail</td> | ||
<td>off | <td>off | on; default: <b>off</b></td> | ||
<td> | <td>When turned on, the data sender retries failed sending attempts until the are successfully delivered.</td> | ||
</tr> | </tr> | ||
</table> | </table> | ||
====Protocol HTTP(S)==== | ====Protocol HTTP(S)==== | ||
---- | |||
<table class="nd-mantable"> | <table class="nd-mantable"> | ||
<tr> | <tr> | ||
Line 161: | Line 140: | ||
</tr> | </tr> | ||
</table> | </table> | ||
====Protocol MQTT==== | ====Protocol MQTT==== | ||
---- | |||
<table class="nd-mantable"> | <table class="nd-mantable"> | ||
<tr> | <tr> |
Revision as of 07:06, 24 August 2020
Template:Networking rutos manual fw disclosure
Summary
The Data to Server feature provides you with the possibility to set up senders that transfer data collected from Modbus slaves to remote servers.
If you're having trouble finding this page or some of the parameters described here on your device's WebUI, you should turn on "Advanced WebUI" mode. You can do that by clicking the "Advanced" button, located at the top of the WebUI.
Data Senders
The To add a new data sender, click the 'Add' button:
==
When you add a new data sender, you will be redirected to its configuration window. The figure below is an example of that window and the table below provides information on the fields that it contains:
File:Networking rutx manual data to server advanced sender settings v1.png
General
Field | Value | Description |
---|---|---|
Enabled | off | on; default: off | Turns the data sender on or off. |
Name | string; default: none | Name of the data sender. Used for easier data senders management purposes only (optional). |
Protocol | HTTP(S) | MQTT | Kinesis; default: HTTP(S) | Protocol used for sending the data to server. |
JSON format | string; default: {"TS": "%t", "D": "%d", "data": %a} | Arranges the format of the sent JSON segment. |
Segment count | integer [1..10]; default: 1 | Max segment count in one JSON string sent to server. |
Send as object | off | on; default: off | When turned on, sends JSON segment as object and not as an array element. |
URL/Host/Connection string | string; default: none | URL for HTTP(S); Host for MQTT; Connection string for Azure MQTT. |
Period | integer [1..86400]; default: 60 | Data sending frequency (in seconds). |
Data filtering | All data | By slave ID | By slave IP; default: All data | Choose which data this sender will send to server. |
By slave ID: Slave ID | integer [1..255]; default: none | ID of the Modbus slave whose collected data will be sent to server. |
By slave IP: Slave IP | ip; default: none | IP address of the Modbus slave whose collected data will be sent to server (for Modbus TCP slaves). |
Retry on fail | off | on; default: off | When turned on, the data sender retries failed sending attempts until the are successfully delivered. |
Protocol HTTP(S)
Field | Value | Description |
---|---|---|
Custom Header | string; default: none | Allows to add custom headers to the HTTP requests. |
Use TLS | off | on; default: off | Enables the use of TSL certificates. |
On: TLS type | Certificate based; default: Certificate based | Select type of TLS. |
On: A File | .ca file; default: none | Certificate authority is an entity that issues digital certificates. A digital certificate certifies the ownership of a public key by the named subject of the certificate. |
On: Client Certificate | .crt file; default: none | Certificate file is a type of digital certificate that is used by client systems to make authenticated requests to a remote server. If client certificate is not needed, leave both client certificate and client key fields empty. |
On: Private Key | .key file; default: none | File containing private key for this client. This file needs to be not encrypted. |
Protocol MQTT
Field | Value | Description |
---|---|---|
Port | integer [0..65535]; default: 1883 | Port number for connecting to MQTT. |
Keepalive | integer [1..640]; default: 60 | MQTT Keepalive period in seconds. |
Topic | string; default: none | MQTT topic to be used for publishing the data. |
QoS | integer [0..2]; default: 0 | MQTT Quality of Service. Allowed values:
|
Use TLS | off | on; default: off | Enables the use of TSL certificates. |
On: TLS type | Certificate based | Pre-shared key based; default: Certificate based | Select type of TLS. |
Certificate based: CA File | .ca file; default: none | Certificate authority is an entity that issues digital certificates. A digital certificate certifies the ownership of a public key by the named subject of the certificate. |
Certificate based: Client Certificate | .crt file; default: none | Certificate file is a type of digital certificate that is used by client systems to make authenticated requests to a remote server. If client certificate is not needed, leave both client certificate and client key fields empty. |
Certificate based: Private Key | .key file; default: none | File containing private key for this client. This file needs to be not encrypted. |
Pre-shared key based: Pre-Shared-Key | string; default: none | The pre-shared-key in hex format with no leading "0x". |
Pre-shared key based: Identity | string; default: none | The identity of this client. May be used as the username depending on the server settings. |
Use Credentials | off | on; default: off | Enables use of username and password for authentication. |
On: Username | string; default: none | Username used in authentication. |
On: Password | string; default: none | Password used in authentication. |
Note: these tables have coloring schemes to indicate which fields can be seen with different configuration.
[[Category:{{{name}}} Services section]]