Difference between revisions of "Template:Networking rutos manual modbus modbus tcp set parameters table"
From Teltonika Networks Wiki
Gytispieze (talk | contribs) |
Gytispieze (talk | contribs) |
||
Line 122: | Line 122: | ||
<tr> | <tr> | ||
<td> Switch PIN 3 direction </td> | <td> Switch PIN 3 direction </td> | ||
− | <td> | + | <td>326</td> |
− | <td> | + | <td>327</td> |
<td>1{{!}}0</td> | <td>1{{!}}0</td> | ||
<td>Toggles PIN 3 direction between INPUT (0) or OUTPUT (1)</td> | <td>Toggles PIN 3 direction between INPUT (0) or OUTPUT (1)</td> | ||
Line 129: | Line 129: | ||
<tr> | <tr> | ||
<td> Switch PIN 4 direction </td> | <td> Switch PIN 4 direction </td> | ||
− | <td> | + | <td>327</td> |
− | <td> | + | <td>328</td> |
<td>1{{!}}0</td> | <td>1{{!}}0</td> | ||
<td>Toggles PIN 4 direction between INPUT (0) or OUTPUT (1)</td> | <td>Toggles PIN 4 direction between INPUT (0) or OUTPUT (1)</td> |
Revision as of 12:04, 30 December 2021
Set Parameters
The Modbus daemon can also set some device parameters.
value to set | register address | register number | register value | description |
---|---|---|---|---|
Hostname | 7 | 8 | Hostname (in decimal form) | Changes hostname |
Device name | 71 | 72 | Device name (in decimal form) | Changes device name |
Reboot | 206 | 207 | 1 | Reboots the router |
Switch PIN 3 state | 324 | 325 | 1|0 | Toggles PIN 3 ON or OFF, when output is selected |
Switch PIN 4 state | 325 | 326 | 1|0 | Toggles PIN 4 ON or OFF, when output is selected |
Switch PIN 3 direction | 326 | 327 | 1|0 | Toggles PIN 3 direction between INPUT (0) or OUTPUT (1) |