'''Averaged''' RUT200 power consumption values in different states of operation are represented in the tables below: | |||
<table class="nd-othertables_3"> | |||
<tr style="font-weight:bold"> | |||
<th width=800>Test type</th> | |||
<th width=150><center>Current (mA)</center></th> | |||
<th width=170><center>Power consumption (W)</center></th> | |||
</tr> | |||
<tr> | |||
<td>Idle, no SIM card inserted (9 V)</td> | |||
<td><center><b>118</b></center></td> | |||
<td><center><b>1.06</b></center></td> | |||
</tr> | |||
<tr> | |||
<td>Idle, no SIM card inserted (12 V)</td> | |||
<td><center><b>96</b></center></td> | |||
<td><center><b>1.15</b></center></td> | |||
</tr> | |||
<tr> | |||
<td>Idle, no SIM card inserted (24 V)</td> | |||
<td><center><b>51</b></center></td> | |||
<td><center><b>1.22</b></center></td> | |||
</tr> | |||
</table> | |||
<table class="nd-othertables_3"> | |||
<tr style="font-weight:bold"> | |||
<th width=800>Test type</th> | |||
<th width=150><center>Current (mA)</center></th> | |||
<th width=170><center>Power consumption (W)</center></th> | |||
</tr> | |||
<tr> | |||
<td>Idle + mobile data on <sup><small>1</small></sup> (9 V)</td> | |||
<td><center><b>125</b></center></td> | |||
<td><center><b>1.16</b></center></td> | |||
</tr> | |||
<tr> | |||
<td>Idle + mobile data on <sup><small>1</small></sup> (12 V)</td> | |||
<td><center><b>99</b></center></td> | |||
<td><center><b>1.19</b></center></td> | |||
</tr> | |||
<tr> | |||
<td>Idle + mobile data on <sup><small>1</small></sup> (24 V)</td> | |||
<td><center><b>55</b></center></td> | |||
<td><center><b>1.32</b></center></td> | |||
</tr> | |||
</table> | |||
<table class="nd-othertables_3"> | |||
<tr style="font-weight:bold"> | |||
<th width=800>Test type</th> | |||
<th width=150><center>Current (mA)</center></th> | |||
<th width=170><center>Power consumption (W)</center></th> | |||
</tr> | |||
<tr> | |||
<td> Mobile data on <sup><small>1</small></sup> + 1 LAN device connected <sup><small>2</small></sup> (9 V)</td> | |||
<td><center><b>142</b></center></td> | |||
<td><center><b>1.29</b></center></td> | |||
</tr> | |||
<tr> | |||
<td> Mobile data on <sup><small>1</small></sup> + 1 LAN device connected <sup><small>2</small></sup> (12 V)</td> | |||
<td><center><b>109</b></center></td> | |||
<td><center><b>1.31</b></center></td> | |||
</tr> | |||
<tr> | |||
<td> Mobile data on <sup><small>1</small></sup> + 1 LAN device connected <sup><small>2</small></sup> (24 V)</td> | |||
<td><center><b>70</b></center></td> | |||
<td><center><b>1.68</b></center></td> | |||
</tr> | |||
</table> | |||
<table class="nd-othertables_3"> | |||
<tr style="font-weight:bold"> | |||
<th width=800>Test type</th> | |||
<th width=150><center>Current (mA)</center></th> | |||
<th width=170><center>Power consumption (W)</center></th> | |||
</tr> | |||
<tr> | |||
<td> 2 LAN devices connected <sup><small>2</small></sup> + high CPU load <sup><small>3</small></sup> + max speed LTE transmission + data transfer via WiFi (9 V)</td> | |||
<td><center><b>426</b></center></td> | |||
<td><center><b>3.83</b></center></td> | |||
</tr> | |||
<tr> | |||
<td> 2 LAN devices connected <sup><small>2</small></sup> + high CPU load <sup><small>3</small></sup> + max speed LTE transmission + data transfer via WiFi (12 V)</td> | |||
<td><center><b>318</b></center></td> | |||
<td><center><b>3.82</b></center></td> | |||
</tr> | |||
<tr> | |||
<td> 2 LAN devices connected <sup><small>2</small></sup> + high CPU load <sup><small>3</small></sup> + max speed LTE transmission + data transfer via WiFi (24 V)</td> | |||
<td><center><b>161</b></center></td> | |||
<td><center><b>3.86</b></center></td> | |||
</tr> | |||
</table> | |||
<small><sup><small>1</small></sup> - Only mobile data connection established with no additional traffic.</small> <br> | |||
<small><sup><small>2</small></sup> - Data streams between RUT200 and other connected LAN devices created using iPerf.</small> <br> | |||
<small><sup><small>3</small></sup> - Load created using ''md5sum'' (calculation and verification of 128-bit MD5 hashes). </small> <br> | |||
<small>Power consumption may differ due to mobile data transmission speed, testing environment and conditions.</small> | |||
[[Category:RUT200 Manual]] |
Latest revision as of 08:52, 12 November 2024
Main Page > RUT Routers > RUT200 > RUT200 Manual > RUT200 Power ConsumptionAveraged RUT200 power consumption values in different states of operation are represented in the tables below:
Test type | ||
---|---|---|
Idle, no SIM card inserted (9 V) | ||
Idle, no SIM card inserted (12 V) | ||
Idle, no SIM card inserted (24 V) |
Test type | ||
---|---|---|
Idle + mobile data on 1 (9 V) | ||
Idle + mobile data on 1 (12 V) | ||
Idle + mobile data on 1 (24 V) |
Test type | ||
---|---|---|
Mobile data on 1 + 1 LAN device connected 2 (9 V) | ||
Mobile data on 1 + 1 LAN device connected 2 (12 V) | ||
Mobile data on 1 + 1 LAN device connected 2 (24 V) |
Test type | ||
---|---|---|
2 LAN devices connected 2 + high CPU load 3 + max speed LTE transmission + data transfer via WiFi (9 V) | ||
2 LAN devices connected 2 + high CPU load 3 + max speed LTE transmission + data transfer via WiFi (12 V) | ||
2 LAN devices connected 2 + high CPU load 3 + max speed LTE transmission + data transfer via WiFi (24 V) |
1 - Only mobile data connection established with no additional traffic.
2 - Data streams between RUT200 and other connected LAN devices created using iPerf.
3 - Load created using md5sum (calculation and verification of 128-bit MD5 hashes).