Difference between revisions of "Template:Networking tsw200 faq power consumption table"
From Teltonika Networks Wiki
(Created page with "<table class="nd-othertables_3"> <tr style="font-weight:bold"> <th width=800>Test type</th> <th width=150>Current (mA)</span></th> <th width=150>Pow...") |
|||
Line 21: | Line 21: | ||
</tr> | </tr> | ||
</table> | </table> | ||
− | |||
<table class="nd-othertables_3"> | <table class="nd-othertables_3"> | ||
Line 30: | Line 29: | ||
</tr> | </tr> | ||
<tr> | <tr> | ||
− | <td>8 LAN and 2 SFP devices connected + heavy data traffic (12 V)</td> | + | <td>8 LAN and 2 SFP devices connected + heavy data traffic<sup><small>1</small></sup> (12 V)</td> |
<td><b>381</b></td> | <td><b>381</b></td> | ||
<td><b>4.57</b></td> | <td><b>4.57</b></td> | ||
</tr> | </tr> | ||
<tr> | <tr> | ||
− | <td>8 LAN and 2 SFP devices connected + heavy data traffic (24 V)</td> | + | <td>8 LAN and 2 SFP devices connected + heavy data traffic<sup><small>1</small></sup> (24 V)</td> |
<td><b>200</b></td> | <td><b>200</b></td> | ||
<td><b>4.80</b></td> | <td><b>4.80</b></td> | ||
</tr> | </tr> | ||
<tr> | <tr> | ||
− | <td>8 LAN and 2 SFP devices connected + heavy data traffic (54 V)</td> | + | <td>8 LAN and 2 SFP devices connected + heavy data traffic<sup><small>1</small></sup> (54 V)</td> |
<td><b>103</b></td> | <td><b>103</b></td> | ||
<td><b>5.54</b></td> | <td><b>5.54</b></td> | ||
</tr> | </tr> | ||
</table> | </table> | ||
− | |||
<table class="nd-othertables_3"> | <table class="nd-othertables_3"> | ||
Line 54: | Line 52: | ||
</tr> | </tr> | ||
<tr> | <tr> | ||
− | <td>2 SFP devices connected + 4 PoE devices (RUTX08, RUTX09, RUTX10, RUTX11) connected + 4 PoE dummy loads connected (30 W each) + heavy data traffic (54 V)</td> | + | <td>2 SFP devices connected + 4 PoE devices (RUTX08, RUTX09, RUTX10, RUTX11) connected + 4 PoE dummy loads connected (30 W each) + heavy data traffic<sup><small>1</small></sup> (54 V)</td> |
<td><b>2405</b></td> | <td><b>2405</b></td> | ||
<td><b>137.10</b></td> | <td><b>137.10</b></td> | ||
</tr> | </tr> | ||
</table> | </table> | ||
+ | |||
+ | <small><sup><small>1</small></sup> - Data streams between devices were created using iPerf.</small> <br> | ||
+ | <small>Power consumption may differ due to testing environment and conditions.</small> |
Revision as of 13:22, 25 April 2022
Test type | Current (mA) | Power consumption (W) |
---|---|---|
Idle (12 V) | 77 | 0.93 |
Idle (24 V) | 52 | 1.24 |
Idle (54 V) | 34 | 1.81 |
Test type | Current (mA) | Power consumption (W) |
---|---|---|
8 LAN and 2 SFP devices connected + heavy data traffic1 (12 V) | 381 | 4.57 |
8 LAN and 2 SFP devices connected + heavy data traffic1 (24 V) | 200 | 4.80 |
8 LAN and 2 SFP devices connected + heavy data traffic1 (54 V) | 103 | 5.54 |
Test type | Current (mA) | Power consumption (W) |
---|---|---|
2 SFP devices connected + 4 PoE devices (RUTX08, RUTX09, RUTX10, RUTX11) connected + 4 PoE dummy loads connected (30 W each) + heavy data traffic1 (54 V) | 2405 | 137.10 |
1 - Data streams between devices were created using iPerf.
Power consumption may differ due to testing environment and conditions.