BAT120 LEDs: Difference between revisions

From Teltonika Networks Wiki
m (Gytispieze moved page Draft:BAT120 LEDs to BAT120 LEDs without leaving a redirect)
No edit summary
 
Line 15: Line 15:
     </tr>
     </tr>
     <tr>
     <tr>
         <td>LED turned ON</td>
         <td>LED turned ON green</td>
         <td>PSU connected to IN PWR socket</td>
         <td>PSU connected to IN PWR socket</td>
     </tr>
     </tr>
    <tr>
    <td>LED turned ON red</td>
    <td>PSU connected to IN PWR socket, charge failure /Vin too low</td>
</table>
</table>


Line 25: Line 28:


[[File:Network_bat_manual_bat120_pwrout_led_v1.png|400px]]
[[File:Network_bat_manual_bat120_pwrout_led_v1.png|400px]]
 
<br>
'''''Note:''' OUT PWR LED will illuminate green when connected load is greater than 0.5W. If the power consumed by an external device is less than 0.5W, it will still be powered, but OUT PWR LED will stay off.''
<table class="nd-othertables_2">
<table class="nd-othertables_2">
     <tr>
     <tr>
Line 32: Line 36:
     </tr>
     </tr>
     <tr>
     <tr>
         <td>LED turned ON</td>
         <td>LED turned ON green</td>
         <td>OUT PWR socket connected to the device</td>
         <td>OUT PWR socket connected to the device and external device is being powered</td>
     </tr>
     </tr>
    <tr>
  <td>LED turned ON red</td>
  <td> If the OUTPUT is shorted (requiring a reset) or the BAT120 has overheated (no reset needed), the OUT PWR LED will turn red, signifying an issue that needs attention. </td>
  </tr>
</table>
</table>


Line 64: Line 73:
     </tr>
     </tr>
     <tr>
     <tr>
         <td>All LEDs blinking every 500ms</td>
         <td>Power LEDs blink every 5 seconds</td>
        <td>BAT120 overheated.</td>
    </tr>
    <tr>
        <td>OUT PWR LED blinking every 500ms</td>
        <td>OUT PWR shorted.</td>
    </tr>
    <tr>
        <td>Power LEDs lighting up in sequence</td>
         <td>BAT120 is charging.</td>
         <td>BAT120 is charging.</td>
    </tr>
    <tr>
        <td>Power LEDs blink every 5 seconds</td>
        <td>BAT120 is in sleep mode.</td>
     </tr>
     </tr>
</table>
</table>

Latest revision as of 10:02, 18 December 2024

Main Page > BAT Uninterruptable Power Supplies > BAT120 > BAT120 Manual > BAT120 LEDs

This wiki page contains information about BAT120 LEDs and their actions.

Power IN LED

The IN PWR LED is the left-most located LED on the front panel:

Action Description
LED turned ON green PSU connected to IN PWR socket
LED turned ON red PSU connected to IN PWR socket, charge failure /Vin too low

Power OUT LED

The OUT PWR LED is the second from the left LED located on the front panel:


Note: OUT PWR LED will illuminate green when connected load is greater than 0.5W. If the power consumed by an external device is less than 0.5W, it will still be powered, but OUT PWR LED will stay off.

Action Description
LED turned ON green OUT PWR socket connected to the device and external device is being powered
LED turned ON red If the OUTPUT is shorted (requiring a reset) or the BAT120 has overheated (no reset needed), the OUT PWR LED will turn red, signifying an issue that needs attention.

Power LEDs

The Power LEDs are located in the middle of the front panel:

Action Description
LED turned ON Shows BAT120 state of charge. Each LED equals to 25% of SOC.

Combined LED states

Some of the states are shown with multiple LEDs:

Action Description
Power LEDs blink every 5 seconds BAT120 is charging.